Mist control at a machining center, Part 1: Mist characterization.

AIHAJ

U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, Division of Physical Sciences and Engineering, Cincinnati, OH 45226-1998, USA.

Published: June 2000

At a machining center used to produce transmission parts, aerosol instrumentation was used to quantitatively study mist generation and to evaluate the performance of an air cleaner for controlling the mist. This machining center drilled and tapped holes at rotational speeds of 1000 to 3000 rpm. During most machining operations, the metal-working fluid (MWF) was flooded over the part. To facilitate metal chip removal during some operations, MWF was pumped through the orifices in some tools at a pressure of 800 psi. These machining operations were performed in a nearly complete enclosure that was exhausted to an air cleaner at a flow rate of 1.1 m3/sec (2400 ft3/m). Although the use of high-pressure MWF increased the mist concentration by about 200%, it did not affect the mist size distribution. The observed penetration through the air cleaner appeared to be mostly consistent with the manufacturer's specifications on the air cleaner's filters. During the testing, MWF was observed to accumulate in the bottom of the filter housing and may have been reentrained due to air motion or mechanical vibration.

Download full-text PDF

Source
http://dx.doi.org/10.1080/15298660008984537DOI Listing

Publication Analysis

Top Keywords

machining center
12
air cleaner
12
machining operations
8
mist
6
machining
5
air
5
mist control
4
control machining
4
center mist
4
mist characterization
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!