Peristaltic pressure profiles of the human esophagus.

J Clin Gastroenterol

Graduate Hospital, Philadelphia, Pennsylvania, USA.

Published: April 2000

Using a low-compliance pneumohydraulic infusion system, we mapped the entire esophagus of nine volunteers with no history of esophageal disease, centimeter by centimeter, to see if there was pressure symmetry throughout the esophagus during 5 mL wet swallows. We found that esophageal length varied from 21-25 cm. The esophageal low-pressure zone (LPZ) varies in distance from the upper esophageal sphincter (UES) (4-8 cm). The length of this LPZ is 2-3 cm in most subjects but low pressures (<50 mmHg) may occur for longer intervals in some. The amplitudes of most paired swallows were within 10 mmHg of each other, and in only 10% of swallows was the pressure difference more than 15 mmHg. We conclude that there is radial pressure symmetry throughout the normal esophagus. The LPZ coincides closely to the 50-50 point where the percentage of striated and smooth muscle distribution in the circular and longitudinal muscles is equal.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00004836-200004000-00013DOI Listing

Publication Analysis

Top Keywords

peristaltic pressure
4
pressure profiles
4
profiles human
4
human esophagus
4
esophagus low-compliance
4
low-compliance pneumohydraulic
4
pneumohydraulic infusion
4
infusion system
4
system mapped
4
mapped entire
4

Similar Publications

Background: The gut, the ureter, or the Fallopian tube all transport biological fluids by generating trains of propagating smooth muscle constrictions collectively known as peristalsis. These tubes connect body compartments at different pressures. We extend here Poiseuille's experiments on liquid flow in inert tubes to an active, mechanosensitive tube: the intestine.

View Article and Find Full Text PDF

Preliminary steps for fabrication of microfluidic systems for swine sperm sorting: Materials, perfusing systems and flow.

Res Vet Sci

February 2025

Tissue Microenvironment (TME) Lab, Aragón Institute of Engineering Research (I3A), University of Zaragoza, 50018 Zaragoza, Spain; Institute for Health Research Aragón (IIS Aragón), 50009 Zaragoza, Spain. Electronic address:

The success rate of assisted reproductive techniques in the livestock production can be optimized by improving the quality of the semen sample by selecting only the good quality sperm from the ejaculate. Microfluidic technology has been studied for sperm sorting mainly in human ejaculates but has not been studied for boar sperm. Spermatozoa have been proven to be highly sensitive to different microplastics, but the potential toxic effects of the materials used to set up microfluidic systems have not been studied.

View Article and Find Full Text PDF

Background: The generation and perfusion of complex vascularized tissues in vitro requires sophisticated perfusion techniques. For multiscale arteriovenous networks, not only the arterial, but also the venous, biomechanical and biochemical conditions that physiologically exist in the human body must be accurately emulated. For this, we here present a modular arteriovenous perfusion system for the in vitro culture of a multi-scale bioartificial vascular network.

View Article and Find Full Text PDF

Background: Internationally adopted Chicago Classification (CC) criteria based on adult normative data have been used to diagnose children with esophageal motility disorders undergoing high-resolution esophageal manometry (HREM). The aim of this study was to compare HREM parameters of children without dysphagia and children with dysphagia and normal findings according to CC.

Methods: HREM metrics of 41 children (13.

View Article and Find Full Text PDF

A novel nucleic acid extraction system integrating a switching valve-assisted microfluidic cartridge and a constant pressure pump.

Anal Chim Acta

November 2024

Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, 230031, Anhui, China. Electronic address:

Background: Nucleic acid extraction (NAE) is essential in molecular diagnostics, genetic engineering, and DNA sequencing. While advances in switching valve-assisted, self-contained microfluidic (SM) cartridges have improved the NAE processes, challenges persist in streamlining workflows, reducing processing times, and enhancing multi-target detection. Achieving these objectives requires precise control of on-chip fluid dynamics and efficient transfer of nucleic acid solutions (NAS) to detection areas.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!