A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

On-to-on versus on-to-out nuchal translucency measurements. | LitMetric

On-to-on versus on-to-out nuchal translucency measurements.

Ultrasound Obstet Gynecol

Department of Obstetrics and Gynecology, Assaf Harofeh Medical Center, Zerifin, Israel.

Published: February 2000

Objective: To analyze variables affecting the differences between on-to-on and on-to-out methods of nuchal translucency measurement.

Design: Prospective comparison of two methods of caliper placement.

Subjects: A total of 245 women undergoing transabdominal and 37 women undergoing transvaginal nuchal translucency scanning.

Methods: Nuchal translucency was measured using both on-to-on and on-to-out methods of caliper placement on the same frozen images. Differences between the methods were evaluated according to fetal size, nuchal thickness and mode of examination. Regression analysis was performed for the calculation of the expected difference between the methods at various combinations. Results among 1254 singleton pregnancies were used to set 50th, 95th and 97.5th centiles for the on-to-on method. The calculated differences were used to set 50th, 95th and 97.5th centiles for the on-to-out method.

Results: The mean difference between on-to-out and on-to-on nuchal translucency, using transabdominal scanning, was 0.95 +/- 0.14 mm. The differences were shown to correlate directly with fetal size and with nuchal thickness. In addition, scans performed transvaginally exhibited a smaller difference between the methods (0.90 mm vs. 0.94 mm; P < 0.05).

Conclusion: The difference between on-to-on and on-to-out nuchal translucency measurements may have a considerable effect on the calculated risk for aneuploidy.

Download full-text PDF

Source
http://dx.doi.org/10.1046/j.1469-0705.2000.00035.xDOI Listing

Publication Analysis

Top Keywords

nuchal translucency
24
on-to-on on-to-out
12
nuchal
8
on-to-out nuchal
8
translucency measurements
8
on-to-out methods
8
methods caliper
8
women undergoing
8
fetal size
8
size nuchal
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!