Subjective tinnitus is a common problem with many etiologies. Objective tinnitus, in which the sound is perceived by both the patient and the examiner, is less common. Objective tinnitus of the vascular type, in which a pulse synchronous bruit is heard by an independent observer, is frequently related to an underlying arterial or arteriovenous malformation, most commonly a dural arteriovenous fistula (DAVF) involving the transverse and sigmoid sinuses. The remaining cases are usually termed "essential" vascular tinnitus, and are presumed to have a venous etiology. In these cases, the audible noise is generally assumed to be produced within the sino-jugular connection, or within an enlarged jugular bulb. We present four documented cases of objective pulse synchronous tinnitus due to focal narrowing (acquired and developmental) of the mid-portion of the transverse dural sinus. In all cases, a bruit was audible directly over a focal constriction in the sinus, demonstrated by cerebral angiography or direct catheter venography. In one case, selective venography revealed a distensible sinus narrowing, associated with a jet of contrast marking fast flow within a developmental sinus segmentation. In another case, a loud pulse synchronous bruit was heard directly over a focal transverse sinus stenosis, which was detected by angiography at the site of a vascular surgical clip. In this case, magnetic resonance (MR) falsely predicted sinus occlusion. In two other cases, an audible bruit was also heard directly overlying a narrowed transverse sinus, seen in the venous phase of angiography. Transverse sinus stenosis is an unappreciated cause of objective pulsatile tinnitus, and we believe that this mechanism may underlie many cases of "essential" or venous etiology tinnitus not otherwise anatomically explained. Non-invasive testing, computed tomography (CT) and MR and non-directed angiography may overlook it. Conventional catheter arteriography or venography should be performed in such cases, with attention to the dural sinuses, if other tests fail to define the anatomic basis of the audible bruit.

Download full-text PDF

Source

Publication Analysis

Top Keywords

pulse synchronous
12
bruit heard
12
transverse sinus
12
sinus
9
tinnitus
8
transverse dural
8
objective tinnitus
8
synchronous bruit
8
venous etiology
8
cases audible
8

Similar Publications

As a low-energy method to increase the data rate of optical links in data centers, we propose self-homodyne Nyquist optical time division multiplexing (OTDM). In Nyquist OTDM, spectrally efficient high-baud rate signals can be generated exceeding the limit of electronic signal processing. However, full integration of OTDM systems has not been reported, mainly because of the complicated signal detection scheme, which involves demultiplexing and clock recovery.

View Article and Find Full Text PDF

Introduction: Our goal was to determine the differences in changes in cardiovascular and cardiorespiratory interaction indicators during a respiratory maneuver with a change in breathing rate in athletes with different types of heart rate regulation.

Methods: The results of a study of 183 healthy men aged 21.2 ± 2.

View Article and Find Full Text PDF

Beaware of Intracardiac Potentials Induced by Intravascular Lithotripsy.

Catheter Cardiovasc Interv

January 2025

Department of Cardiology, Ageo Central General Hospital, Saitama, Japan.

Background: Intravascular lithotripsy (IVL), that generates shockwaves through spark gap discharge between emitters, has been increasingly used to treat severely calcified coronary artery lesions. However, there is a question as to whether IVL has no electrical effects on endocardial tissues or cardiac implantable devices (CIEDs).

Aims: The aim of this study was to investigate the effects of IVL-induced intracardiac potentials on cardiac electrophysiology and CIEDs.

View Article and Find Full Text PDF

This study investigates the effects of electrical stimulation (EMS) combined with strength training on lower limb muscle activation and badminton jump performance, specifically during the "jump smash" movement. A total of 25 male badminton players, with a minimum of three years of professional training experience and no history of lower limb injuries, participated in the study. Participants underwent three distinct conditions: baseline testing, strength training, and EMS combined with strength training.

View Article and Find Full Text PDF

The growing demand for high-speed data transfer and ultralow latency in wireless networks-on-chips (WiNoC) has spurred exploration into innovative communication paradigms. Recent advancements highlight the potential of the terahertz (THz) band, a largely untapped frequency range, for enabling ultrafast tera-bit-per-second links in chip multiprocessors. However, the ultrashort duration of THz pulses, often in the femtosecond range, makes synchronization a critical challenge, as even minor timing errors can cause significant data loss.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!