The first purpose of this study was to evaluate the saddle prosthesis in patients with periacetabular tumors in terms of the functional results obtained after several postoperative intervals. The second purpose was to evaluate the complications and how they might be prevented in the future. Functional results according to the MSTS functional rating system were evaluated at several postoperative intervals in 15 patients treated with internal hemipelvectomy and reconstruction with the saddle prosthesis because of periacetabular primary (n = 9) or secondary (n = 6) malignancies. All complications were evaluated. Three months postoperatively, 7/9 patients with a primary tumor and 2/4 patients with a secondary tumor were able to walk outside without pain. Median functional results 3 and 6 months postoperatively were 40% and 50%, respectively. Deep infection occurred in 4 patients and fracture of the iliac remnant in 2. Heterotopic ossifications along the interpositional component were seen in 5 patients, but they did not negatively influence the functional outcome. Three (relative) contraindications to reconstruction with the saddle prosthesis could be ascertained: osteoporosis, extended involvement of the iliac wing by tumor, and insufficient soft-tissue quality after previous procedures. (Short-term) functional results after reconstruction with the saddle prosthesis are satisfactory if the above-mentioned contraindications are taken into consideration.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s004020050041DOI Listing

Publication Analysis

Top Keywords

saddle prosthesis
20
postoperative intervals
12
reconstruction saddle
12
primary secondary
8
functional postoperative
8
months postoperatively
8
functional
7
patients
6
saddle
5
prosthesis pelvic
4

Similar Publications

Cycling is a beneficial physical activity for rehabilitating individuals with lower-limb amputations and serves as a feasible leisure sport. However, the optimal bicycle configuration for cycling with a unilateral transtibial prosthesis at leisure levels has not been investigated. For saddle height at professional cycling levels, existing literature suggests utilizing the same configuration as that used by intact cyclists, where the knee reaches 25-35° at maximum extension.

View Article and Find Full Text PDF

Purpose: This retrospective comparative study aimed to compare the native patellar alignment and clinical outcomes of the Rotating Concave-Convex (ROCC) knee, which features a saddle-shaped rotating platform (RP) insert and a deep trochlea, versus the low contact stress (LCS) knee, which has favourable long-term outcomes and features an anatomically shaped trochlea and a cruciate-sacrificing RP insert. We hypothesized that the deeper trochlea of the ROCC would further stabilize the native patella, resulting in superior clinical outcomes compared to LCS-RP.

Methods: Consecutive patients who underwent patellar-nonresurfacing primary total knee arthroplasty (TKA) using ROCC or LCS-RP were retrospectively reviewed.

View Article and Find Full Text PDF

Thoracolumbar (TL) burst fracture is one of the most common indications for minimally invasive percutaneous pedicle screw fixation. Although the indication for surgical treatment of neurologically intact TL fractures remains under debate, studies have demonstrated that posttraumatic malalignment may lead to a deterioration in the patient's quality of life. For burst fractures with malalignment or fragments in the spinal canal, a reduction technique using ligamentotaxis is commonly used to improve long-term outcomes.

View Article and Find Full Text PDF

Passive fit and time efficiency for prefabricated versus conventionally constructed cobalt chromium CAD\CAM 3-unit implant supported frameworks in free end saddle models: a pilot invitro study.

BMC Oral Health

October 2024

Professor of Prosthodontics and Member of Evidence Based Dentistry Centre, Faculty of Dentistry, Cairo University, Vice Dean of School of Dentistry, Badya University, 11 Al Saraya, Al Manial, Giza Governorate, Cairo, Egypt.

Background: The passive fit of 3-unit implant supported prefabricated metal screw-retained prosthesis before implant placement might be difficult. Hence, we aim to evaluate the passive fit and time efficiency of CAD/CAM 3-unit implant supported fixed prostheses that were constructed based on virtual versus those based on actual implant positions in Kennedy Class I models.

Methods: A sample of 5 Kennedy class I models with thin wiry ridges were restored by 20 frameworks bilaterally, 10 based on actual (group A) and 10 based on virtual (group V) implant positions.

View Article and Find Full Text PDF

Finite-element analysis of different fixation types after Enneking II + III pelvic tumor resection.

Sci Rep

September 2024

Key Laboratory of Engineering Bionics, Ministry of Education, Jilin University, Changchun, 130012, China.

The current primary treatment approach for malignant pelvic tumors involves hemipelvic prosthesis reconstruction following tumor resection. In cases of Enneking type II + III pelvic tumors, the prosthesis necessitates fixation to the remaining iliac bone. Prevailing methods for prosthesis fixation include the saddle prosthesis, ice cream prosthesis, modular hemipelvic prosthesis, and personalized prosthetics using three-dimensional printing.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!