Download full-text PDF |
Source |
---|
Sensors (Basel)
December 2024
Assessment of Movement Behaviours (AMBer), Leicester Lifestyle and Health Research Group, Diabetes Research Centre, University of Leicester, Leicester LE5 4PW, UK.
Background: Following shoulder surgery, controlled and protected mobilisation for an appropriate duration is crucial for appropriate recovery. However, methods for objective assessment of sling wear and use in everyday living are currently lacking. In this pilot study, we aim to determine if a sling-embedded triaxial accelerometer and/or wrist-worn sensor can be used to quantify arm posture during sling wear and adherence to sling wear.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Faculty of Health Sciences Brandenburg, Brandenburg Medical School Theodor Fontane, 14770 Brandenburg an der Havel, Germany.
Determining whether preoperative performance-based knee function predicts postoperative performance-based knee function and whether patient-reported outcome measures (PROMs) completed by participants can detect these changes could significantly enhance the planning of postoperative rehabilitation for patients following total knee arthroplasty (TKA). This study aims to collect data on performance-based knee function using inertial measurement units (IMUs) worn by participants both preoperatively and postoperatively. PROMs will be completed by the patients before and after surgery to assess their ability to detect the same changes in performance-based knee function measured by the sensors.
View Article and Find Full Text PDFJMIR Mhealth Uhealth
January 2025
ULR 7369 - URePSSS - Unité de Recherche Pluridisciplinaire Sport Santé Société, Univ. Littoral Côte d'Opale, Univ. Lille, Univ. Artois, 189b, Avenue Maurice Schumann, Centre Universitaire des Darses, Dunkerque, 59375, France, 33 328237357.
Background: Wrist-worn photoplethysmography (PPG) sensors allow for continuous heart rate (HR) measurement without the inconveniences of wearing a chest belt. Although green light PPG technology reduces HR measurement motion artifacts, only a limited number of studies have investigated the reliability and accuracy of wearables in non-laboratory-controlled conditions with actual specific and various physical activity movements.
Objective: The purpose of this study was to (1) assess the reliability and accuracy of the PPG-based HR sensor of the Fitbit Charge 4 (FC4) in ecological conditions and (2) quantify the potential variability caused by the nature of activities.
PLoS One
January 2025
Department of Kinesiology and Health Science, Virginia Commonwealth University, Richmond, VA, United States of America.
Introduction: The ActiGraph (AG) accelerometer is widely used to assess physical activity (PA) in heart failure (HF) patients. However, the validity of the AG in this population remains unexplored.
Objective: Therefore, this study examined the criterion validity of the AG-GT9X for measuring step counts (SC) and energy expenditure (EE) among HF patients.
Health Phys
January 2025
Department of Physics, Toronto Metropolitan University, 350 Victoria Street, Toronto, Ontario, M5B 2K3.
This study elucidated the radiation response characteristics of a Gafchromic radiochromic film subjected to low photon doses of ≤50 mSv, which corresponds to the annual whole body effective dose limit for radiation workers in Canada. Radiochromic films are investigated for possible use as a complementary tool for the Canadian Armed Forces that can be worn in addition to their existing personal dosimetry to quickly assess personal radiation dose received from radiological hazards without reliance on electronics. The films were exposed to varying photon energies emanating from x-ray generators and radioisotopes, specifically cesium-137, cobalt-60, and americium-241.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!