Background: The accumulation of beta2-microglobulin (beta2-M) in long-term dialysis patients may lead to dialysis amyloidosis. In this respect, the removal with different modes of on-line haemodiafiltration (HDF) of beta2-M was studied. Long-term clinical observations in patients with more than 10 years of dialysis, treated mainly with biocompatible and highly permeable membranes and in the last years with on-line HDF are also reported.

Methods: In the first part of this report, the reduction ratios and clearances of beta2-M, blood urea nitrogen, creatinine and phosphorus (P) of on-line HDF with 40 to 120 ml/min replacement fluid are compared with bicarbonate haemodialysis (HD). In the second part, we investigated 16 patients with more than 10 years of dialysis treatment. The prevalence of dialysis amyloidosis and the mean values for serum albumin, serum total cholesterol, HDL and LDL cholesterol and parathyroid hormone are reported, as well as the mean dose of erythropoietin.

Results: In the first part with on-line HDF, starting from HDF 60 ml/min a significantly higher beta2-M reduction ratio and clearance vs HD is noted. In HDF100 (i.e. with 241 replacement volume per 4-h treatment) vs HD, a beta2-M reduction ratio of 72.7% vs 49.7% (P= 0.0000) and a beta2-M clearance of 116.8 vs 63.8 ml/min (P=0.0000) was obtained. Comparing HDF120 with HDF100, there is a significantly higher beta2-M clearance with the former (P<0.005), although the beta2-M reduction ratio was not significantly better. In the HDF120 session the amount of beta2-M in the total dialysate was 292 mg per session. If one adds the known 17% adsorption on the polysulfone membrane, a total of 341.6 mg beta2-M per session is removed, which adds up to 1024.8 mg a week. Concerning the small molecules, our results with HDF100 also show a higher creatinine and especially P clearance vs HD. In the second part with 16 patients with more than 10 years of dialysis treatment (mean 14 years 1 month), the mean time on HDF amounted to 39.5% of the total treatment time. In four patients only biocompatible and highly permeable membranes were used, AN69 and mainly polysulfone, and in four other patients these membranes were used for more than 95% of the treatment time. Therefore, it is not surprising that the prevalence of carpal tunnel syndrome was only 12.5% in the patients after 10 years of dialysis. Twenty-five percent of these patients met the criteria for diagnosis of beta2-M bone-amyloidosis, proposed by van Ypersele de Strihou et al., but without a retrospective X-ray analysis. The mean predialysis beta2-M value was 29.6 mg/l. The mean values for serum albumin, serum total cholesterol, HDL and LDL cholesterol were within normal limits. For the parathyroid hormone a mean of 287.5 pg/ml was found. Subtotal parathyroidectomy was performed in five patients. The mean dose of 43 U erythropoietin/kg per session is comparable with those reported in the literature. Conclusions. Like Canaud, in our renal unit, treatment with on-line HDF with a highly permeable and biocompatible membrane has proven to be an efficient, well-tolerated and safe technique. Furthermore it leads to a low prevalence of dialysis amyloidosis and a superior P clearance. However, continuous attention must be paid to an on-line sterile and apyrogenic dialysate. Although on-line HDF is undoubtedly a more optimal approach of chronic dialytic treatment, it also carries a higher cost, which is currently evaluated to be nearly US$11 per session.

Download full-text PDF

Source
http://dx.doi.org/10.1093/oxfordjournals.ndt.a027964DOI Listing

Publication Analysis

Top Keywords

on-line hdf
12
on-line haemodiafiltration
8
long-term clinical
8
clinical observations
8
dialysis amyloidosis
8
patients years
8
years dialysis
8
higher beta2-m
8
beta2-m reduction
8
reduction ratio
8

Similar Publications

Article Synopsis
  • Chronic kidney patients struggle with waste elimination and mineral balance in their blood, and hemodialysis (HD) serves as a critical treatment to address these issues.
  • Reverse osmosis (RO) water, with low total dissolved solids, is used for creating dialysis fluid, and the purity of this water is assessed using advanced techniques like laser-induced breakdown spectroscopy (LIBS).
  • Comparative studies show that the ultrapure RO water from on-line hemodiafiltration (HDF) machines offers better electrolyte balance for patients, enhancing their quality of life, although the filtration capacity of dialyzers diminishes with repeated use.
View Article and Find Full Text PDF

Introduction: The antibody response to SARS-CoV-2 vaccine in haemodialysis (HD) patients is diminished compared to healthy subjects. The aim of this study was to compare the presence of reactive SARS-CoV-2 antibodies in patients with high-flux HD and on-line haemodiafiltration (HDF) three and 6 months after the second dose of SARS-CoV-2 vaccine since previous studies indicate that a sustained antibody response correlates with protection from disease.

Methods: We included 216 HD patients of which 157 had on-line HDF and 59 high-flux HD and 46 health care workers as controls and studied the presence of reactive anti-spike IgG antibodies three and 6 months after the second dose of SARS-CoV-2 vaccine.

View Article and Find Full Text PDF

Background: Hemodialysis (HD) techniques that best remove molecules in the middle to high molecular weight range are on-line hemodiafiltration (OL-HDF) and HD with medium cut-off (MCO) membranes. The aim of this study was to compare efficacy and safety of OL-HDF with FxCordiax HDF 800™, with HD with 2 MCO dialyzers: Theranova 500® and the new Elisio 21HX™ dialyzer.

Methods: Fourteen patients following treatment with OL-HDF using FxCordiax HDF 800™ were randomized to receive a consecutive 1-week HD treatment with Theranova 500® and Elisio 21HX™.

View Article and Find Full Text PDF

Water-Soluble Vitamins and Trace Elements Losses during On-Line Hemodiafiltration.

Nutrients

August 2022

Department of Nephrology, Dialysis and Nutrition, Hospices Civils de Lyon, Lyon Sud Hospital, 69495 Pierre Bénite, France.

Maintenance hemodialysis induces water-soluble vitamins and trace elements losses, which is why recommendations regarding potential supplementation were provided, but mainly based on conventional hemodialysis. This study's aim was to measure the water-soluble vitamins and trace element losses during one on-line post-dilution hemodiafiltration (HDF) session. Thirty-nine patients under maintenance HDF were enrolled.

View Article and Find Full Text PDF

Sustainability and environmental impact of on-line hemodiafiltration.

Semin Dial

September 2022

AURA Paris, Ivry sur Seine, France.

Environment has become a main issue of human activities. Chronic hemodialysis (HD) therapy saves lives but consumes large amounts of water and power and produces a lot of care-related waste. On-line hemodiafiltration (HDF) improves patients' outcomes but increases water consumption from ultra-pure water needs and infusion volume.