The extension of ultrasound (US) color flow imaging (CFI) techniques to high frequencies (> 20 MHz) has the potential to provide valuable noninvasive tools for scientific and clinical investigations of blood flow in the microcirculation. We describe the development of a slow-scan CFI system operating in the 20-100-MHz range that has been optimized to image the microcirculation. The apparatus has incorporated elements of a previously reported pulsed-wave Doppler system and is capable of operating in either CFI or pulsed-wave mode. The performance of the CFI system was evaluated at a center frequency of 50 MHz using two PVDF transducers with -6-dB beam widths of 43 and 60 microm. The -6 dB-axial resolutions were estimated to be 66 and 72 microm, respectively. In vivo validation experiments conducted using the murine ear model demonstrated the detection of flow in vessels down to 15-20 microm in diameter with flow velocities on the order of mm per s. Further experiments examining experimental murine tumors confirmed the successful detection of flow in the tumor microcirculation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0301-5629(99)00101-5 | DOI Listing |
J Am Chem Soc
January 2025
Key Laboratory of Green Printing, CAS Research/Education Center for Excellence in Molecular Sciences, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, P. R. China.
Colloidal crystal engineering enables the precise construction of structures with remarkable properties. However, the flexible and synergistic regulation of multiple properties of colloidal crystals remains a significant challenge. Here, we inspire from Brazilian opals to self-assemble polymer nanoparticles in the gaps of a single-layer opal substrate to fabricate large-scale binary colloidal crystals (BCCs).
View Article and Find Full Text PDFAnal Sci
January 2025
Graduate School of Pharmaceutical Sciences, Tokushima University, 1-78-1 Shomachi, Tokushima, 770-8505, Japan.
A digital-movie-based flow colorimetry for pH measurement using a universal indicator has been applied to the end point detection of acid-base titrations. A two-channel flow system of feedback-based flow ratiometry, primarily consisting of two peristaltic pumps, a digital microscope-based detector, and a laptop computer, was constructed; a Visual Basic.NET program written in-house was used for automating the analytical processes.
View Article and Find Full Text PDFPLoS One
January 2025
Department of Radiology, The First People's Hospital of Xiaoshan District, Xiaoshan Affiliated Hospital of Wenzhou Medical University, Hangzhou, Zhejiang, China.
Background: Previous studies have shown that higher uterine artery pulsatility index (UtA-PI) values in early pregnancy have predictive value for the risk of preeclampsia (PE). However, the sensitivity and specificity of this marker remain controversial. This study aims to explore further the association between UtA-PI in early pregnancy and the incidence of preeclampsia.
View Article and Find Full Text PDFMicrosyst Nanoeng
January 2025
Department of Chemical and Biomolecular Engineering, Chonnam National University, 50 Daehak-ro, Yeosu-si, Jeollanam-do, 59626, Republic of Korea.
Developing a portable yet affordable method for the discrimination of chemical substances with good sensitivity and selectivity is essential for on-site visual detection of unknown substances. Herein, we propose an optofluidic paper-based analytical device (PAD) that consists of a macromolecule-driven flow (MDF) gate and photonic crystal (PhC) coding units, enabling portable and scalable detection and discrimination of various organic chemical, mimicking the olfactory system. The MDF gate is designed for precise flow control of liquid analytes, which depends on intermolecular interactions between the polymer at the MDF gate and the liquid analytes.
View Article and Find Full Text PDFBMC Oral Health
January 2025
Department of Endodontics, Faculty of Dentistry, Cukurova University, Adana, 01380, Turkey.
Objective: This in vitro study aimed to investigate the effect of five polishing systems on the surface roughness (SR) and color change (CC) of novel bulk-fill composite resins.
Methods: Fifty composite resin samples were prepared for each of the five groups: Stark Bulk Fill, SDR Plus, SonicFill 3, Charisma Bulk Flow One, and Filtek Z250. Each group of composite resins was further subdivided into five subgroups based on the polishing method applied: OptraGloss (OG), OptraGloss combined with Diapolisher paste (OG), OptiDisc (OD), OptiDisc combined with Diapolisher paste (OD), and Occlubrush (OCC) (n = 10).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!