The NucliSens Extractor in combination with the 2.0 version of the Roche Cobas HCV Amplicor test has been validated by five European blood screening laboratories in a multi-centre study. For testing the performance characteristics of this HCV-NAT method, the European Pharmacopoeia validation guidelines were followed. The CLB VQC reference reagents were used for testing robustness and sensitivity. After a technical improvement in the extraction stations, the NucliSens Extractor appeared to be contamination-free as was proved by testing negative controls alternating with samples containing a high HCV-RNA concentration. The Pelicheck HCV-RNA genotype 1 dilution panel was tested 74 times in the five laboratories and an overall 95% detection limit of 80 genome equivalents (geq)/ml was found. In one laboratory the Pelicheck panel was tested in 25 runs and here a 95% detection limit of 32 geq/ml was achieved. In this laboratory the Pelispy HCV-RNA run control samples of 140 geq/ml were consistently picked up in all extractor stations. In addition the laboratories have tested a WHO HCV-RNA genotype 1 standard dilution series 39 times and a Pelicheck HCV-RNA genotype 3 reference panel in 32 test runs. The limiting dilution analysis enabled us to compare the detection efficiency of the NucliSens-Amplicor method for the genoype 1 and genotype 3 isolates and to calibrate the reference reagents against each other. The combined Nuclisens-Amplicor method was found to detect the genotype 3 isolate in the Pelicheck HCV-RNA panels with 2-3 fold lower efficiency than the genotype 1 standard (assuming that the historical calibration of the genotype 3 against the genotype 1 standard is correct). In this study of a single method 1 IU of the WHO HCV-RNA standard was found to be equivalent to 5.1 geq of the VQC HCV-RNA standard (95% confidence intervals 3.1-9.1 geq). To avoid confusion with the use of the CLB VQC reagents we accept the NIBSC collaborative study in which calibration by a variety of methods showed that the Pelispy 380 geq/ml run control is equivalent to 100 IU/ml of the WHO standard. This multi-centre validation study demonstrates that the 95% detection limit of the NucliSens HCV Amplicor method lies far below the detection limits required by the international regulatory bodies.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1006/biol.1999.0225 | DOI Listing |
Ann Clin Microbiol Antimicrob
September 2016
Diagnostic Infectious Disease Testing Laboratory, Cincinnati Children's Hospital Laboratory, 3333 Burnet Avenue, MLC 1010, Cincinnati, OH, 45229, USA.
J Clin Microbiol
September 2015
BC Centre for Excellence in HIV/AIDS, Vancouver, British Columbia, Canada
Persons with hepatitis C virus (HCV) genotype 1a (GT1a) infections harboring a baseline Q80K polymorphism in nonstructural protein 3 (NS3) have a reduced virologic response to simeprevir in combination with pegylated interferon-alfa and ribavirin. We aimed to develop, validate, and freely disseminate an NS3 clinical sequencing assay to detect the Q80K polymorphism and potentially other HCV NS3 drug resistance mutations. HCV RNA was extracted from frozen plasma using a NucliSENS easyMAG automated nucleic acid extractor, amplified by nested reverse transcription-PCR, and sequenced using Sanger and/or next-generation (MiSeq) methods.
View Article and Find Full Text PDFPLoS One
March 2013
Central Virology Laboratory, Public Health Services, Israel Ministry of Health, Sheba Medical Center, Tel Hashomer, Israel.
Knowing when, and to what extent co-extracted inhibitors interfere with molecular RNA diagnostic assays is of utmost importance. The QIAamp Viral RNA Mini Kit (A); MagNA Pure LC2.0 Automatic extractor (B); KingFisher (C); and NucliSENS EasyMag (D) RNA extraction systems were evaluated for extraction efficiency and co-purification of inhibitors from stool suspensions.
View Article and Find Full Text PDFJ Virol Methods
February 2011
Scottish National Blood Transfusion Service Transfusion Transmissible Infections Group, Scottish National Blood Transfusion Service, 21 Ellen's Glen Road, Edinburgh EH177QT, United Kingdom.
Serological screening assays have greatly reduced, but not eliminated, the risk of transmission of viral infections by transfusion of blood and blood products. In addition, the 1999 regulation of the European Agency for the Evaluation of Medicinal Products requiring all plasma for fractionation to have tested negative for hepatitis C virus (HCV) RNA (CPMP/BWP/390/97, 1998) led many blood transfusion services to introduce nucleic acid amplification technology (NAT) to screen blood donations for HCV, and in some services for human immunodeficiency virus (HIV) and hepatitis B virus (HBV). BioMérieux's second-generation system, the NucliSENS easyMAG, was evaluated as a suitable platform for the automated extraction of nucleic acids for use with the existing SNBTS NAT assays.
View Article and Find Full Text PDFJ Virol Methods
August 2008
bioMérieux Molecular Biology Center, Christophe Mérieux Center, 5 Rue des Berges, 38 024 Grenoble Cedex 01, France.
A new mechanism is described for DNA amplification using nucleic acid sequence-based amplification (NASBA) including a restriction enzyme digestion and P1 primer binding directly upstream of the digestion. For hepatitis B virus (HBV), herpes simplex virus (HSV) and methicillin resistant Staphylococcus aureus (MRSA) DNA, which all show very poor amplification with normal NASBA, assay sensitivity was improved by a factor 100-1000 when restriction enzyme digestion was performed prior to amplification. For the quantitative HBV assay, in combination with the NucliSENS Extractor (bioMérieux, Boxtel, The Netherlands), a 95% target detection rate of 242 WHO IU/ml and 50% detection rate of 35 WHO IU/ml was achieved.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!