Rationale And Objectives: To evaluate neointimal hyperplasia, plaque distribution, and morphologic features of peripheral arterial stent-grafts with intravascular ultrasound (IVUS).

Methods: Twenty-three patients with stenoses or occlusions of the pelvic or femoral arteries were treated with 31 stent-grafts. Angiography and IVUS of the stented artery were performed 13.9 +/- 9.7 months after stent implantation. Maximum in-stent restenosis was measured by IVUS. Plaque composition and lesion topography were also assessed.

Results: The maximum in-stent restenosis was 53.2 +/- 26.5% for the femoral and 14.2 +/- 10.1 for pelvic arterial stent-grafts. Predilection sites of maximum neointimal tissue accumulation were the edges of the femoral stent-grafts. Only small amounts of neointimal hyperplasia were found in the stent-graft edges. No predilection site for maximum in-stent restenosis was found for the pelvic arterial stent-grafts.

Conclusions: Predilection sites of maximum in-stent restenosis were the edges of femoral stent-grafts in contrast to pelvic stent-grafts. Femoral stent-grafts showed significantly higher graded stenoses with IVUS than iliac stent-grafts. The authors' findings at IVUS did not change the treatment plan in these patients treated with stent-grafts.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00004424-200002000-00002DOI Listing

Publication Analysis

Top Keywords

maximum in-stent
16
in-stent restenosis
16
arterial stent-grafts
12
femoral stent-grafts
12
stent-grafts
10
intravascular ultrasound
8
peripheral arterial
8
neointimal hyperplasia
8
treated stent-grafts
8
pelvic arterial
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!