Medical, surgical and audiological complications of the first 100 adult cochlear implant patients in Birmingham.

J Laryngol Otol Suppl

Department of Otolarynology, University Hospital Birmingham, Queen Elizabeth Hospital, Edgbaston, UK.

Published: February 2000

AI Article Synopsis

  • The Midland Cochlear Implant Programme studied 100 patients, finding the main causes of deafness were idiopathic (31%), meningitis (28%), and cochlear otosclerosis (16%).
  • Major complications occurred in 3% of cases, with the most severe leading to a cerebral infarct and death; minor complications were more common at 39% but all resolved successfully.
  • Older patients and men were at higher risk for post-operative complications, while women had more issues with electrode insertion; patients with over 15 active electrodes performed better on auditory tests.

Article Abstract

Of the first 100 patients implanted on the Midland Cochlear Implant Programme the commonest aetiologies of deafness were idiopathic 31 per cent, meningitis 28 per cent and cochlear otosclerosis 16 per cent. The major complication rate was three per cent. The most severe was one individual who post-operatively developed a cerebral infarct and subsequently died. The minor complication rate was 39 per cent, all of which successfully resolved, and included 11 cases of wound infection, nine cases of vertigo, three transient facial palsies and two post-operative bleeds. Older patients and men were most likely to have a post-operative medical complication. Women were more likely to have an abnormal electrode insertion. Meningitis and otosclerosis were the most complicated aetiologies in terms of cochlear ossification and electrode insertion. A non-patient cochlea was associated with fewer active electrodes. In six cases which had been reported pre-operatively as showing patent cochleas, some form of obstructional ossification was encountered. Patients functioning with greater than 15 active electrodes performed better on auditory tests than patients with fewer than 15 active electrodes.

Download full-text PDF

Source
http://dx.doi.org/10.1017/s002221510014602xDOI Listing

Publication Analysis

Top Keywords

active electrodes
12
cochlear implant
8
complication rate
8
electrode insertion
8
fewer active
8
patients
5
cent
5
medical surgical
4
surgical audiological
4
audiological complications
4

Similar Publications

Renewable energy-driven electrochemical CO2 reduction has emerged as a promising technology for a sustainable future. However, achieving efficient production of storable liquid fuels at ampere-level current densities remains a significant hurdle in the large-scale implementation of CO2 electroreduction. Here we report a novel catalytic electrode comprising chlorine-doped SnO2 nanoflowers arrayed on the exterior of three-dimensional nickel hollow fibers.

View Article and Find Full Text PDF

Objective: Cognitive deficits are one of the most debilitating comorbidities in epilepsy and other neurodegenerative, neuropsychiatric, and neurodevelopmental brain disorders. Current diagnostic and therapeutic options are limited and lack objective measures of the underlying neural activities. In this study, electrophysiological biomarkers that reflect cognitive functions in clinically validated batteries were determined to aid diagnosis and treatment in specific brain regions.

View Article and Find Full Text PDF

GaO Schottky photodiodes are being actively explored for solar-blind ultraviolet (SBUV) detection, owing to the fast photoresponse and easy fabrication. However, their performance, limited by the Schottky contact, mostly underperforms the expectations. Herein, a Ni/β-GaO vertical Schottky barrier diode (SBD) with an ultrathin anode electrode is demonstrated.

View Article and Find Full Text PDF

Cyclic Voltarefractometry of Single TiO Nanoparticles in Large Ensembles in Nonaqueous Electrolyte.

Anal Chem

January 2025

Nanobiotechnology Department of the Institute of Biotechnology, Brandenburg University of Technology Cottbus-Senftenberg, Universitaetsplatz 1, Senftenberg 01968, Brandenburg, Germany.

Single nanoparticle (NP) cyclic voltarefractometry (CVR), realized as wide-field surface plasmon resonance microscopy (SPRM) in combination with potential cycling, has been proposed and applied to the in situ study of TiO NPs. Electrochemical activity of TiO is mainly observed outside the electrochemical stability window of water. Therefore, the response of individual anatase (a-TiO) and rutile (r-TiO) NPs adsorbed on a gold layer was studied in 0.

View Article and Find Full Text PDF

Addressing the pressing need to develop affordable and efficient catalysts is essential. In this study, we successfully synthesized CuBiS nanostructures with a modified morphology using three different nitrogen bases: DBN, DBU, and DABCO a hydrothermal technique. These nanostructures were used for the electrochemical detection of organic nitro groups, a previously unexplored application for this material.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!