Randomized controlled trial of stented and stentless aortic bioprotheses: hemodynamic performance at 3 years.

Semin Thorac Cardiovasc Surg

Department of Cardiothoracic Surgery and Cardiology, The Western Infirmary, Glasgow, Scotland.

Published: October 1999

A randomized prospective trial was undertaken to compare the hemodynamic performance and left ventricular regression after aortic valve replacement with the Toronto SPV stentless bioprosthesis and the Carpentier Edwards SAV (CE) bioprosthesis. Forty patients were randomized after the annular and sinotubular diameters had been measured. Early hemodynamic measurements were made with a thermodilution cardiac output catheter, and echocardiography was used thereafter. Left ventricular mass was assessed using magnetic resonance imaging (MRI) at 1 week, 6 months, and 32 months. The mean annular size was 25.3+/-2.2 mm (CE) and 25.5+/-1.5 mm (Toronto), although it was possible to implant valves with a mean diameter 3 mm larger in the stentless group (26.0+/-1.7 mm cf. 23.0+/-1.7 mm). Hemodynamic performance in the first 24 hours showed no significant difference between the groups, but there was a trend for shorter ventilation time and shorter stays in the intensive therapy unit in the stentless group. Echocardiography showed superior transvalvular gradients in the stentless group at 1 week (mean 5.5+/-3.1 mm Hg cf. 8.9+/-2.5 mm Hg), and this difference was maintained at a mean follow-up time of 32 months (3.5+/-0.6 mm Hg cf. 6.3+/-0.6 mm Hg). Similar regression of left ventricular mass was seen in both groups at 6 months, but at 32 months, measurement in diastole showed a reduction of 38% (P<.01) in the stentless group compared with 20% (P = ns) in the stented group, and measurements in systole showed a 23% (P<.01) and 13% (P = ns) reduction, respectively. This study confirms that a larger stentless valve can be implanted into a given size of aortic annulus with superior residual aortic valve gradients. These lower gradients seem to result in improved long-term regression of left ventricular mass as measured by MRI.

Download full-text PDF

Source

Publication Analysis

Top Keywords

hemodynamic performance
12
left ventricular
12
stentless group
12
ventricular mass
8
months months
8
stentless
5
months
5
randomized controlled
4
controlled trial
4
trial stented
4

Similar Publications

Objectives: The pulse pressure (PP) is an important factor influencing the outcomes of diabetes. However, the relationship between the PP and prediabetes has been rarely studied and how this association might be impacted by hypertension is not clear.

Methods: In this study, we retrospectively included 184,252 adults from 32 regions in China, spanning from 2010 to 2016.

View Article and Find Full Text PDF

Genetic influence on choroidal vascularity index.

PLoS One

January 2025

Department of Ophthalmology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.

Purpose: To investigate the heritability of genetic influence on macular choroidal vascularity index (CVI).

Methods: Total choroidal area (TCA), luminal area (LA), and CVI was measured using horizontal scan of spectral-domain optical coherence tomography with enhanced depth imaging in the 373 healthy twin participants. Characteristics of the participants were investigated, including age, sex, axial length, hypertension, diabetes, drinking habits, and smoking status.

View Article and Find Full Text PDF

This study aims to evaluate the implementation of concomitant CAD assessment on pre-TAVI (transcatheter aortic valve implantation) planning CTA (CT angiography) aided by CT-FFR (CT-fractional flow reserve) [The CT2TAVI protocol] and investigates the incremental value of CT-FFR to coronary CT angiography (CCTA) alone in the evaluation of patients undergoing CT2TAVI. This is a prospective observational real-world cohort study at an academic health system on consecutive patients who underwent CTA for TAVI planning from 1/2021 to 6/2022. This represented a transition period in our health system, from not formally reporting CAD on pre-TAVI planning CTA (Group A) to routinely reporting CAD on pre-TAVI CTA (Group B; CT2TAVI protocol).

View Article and Find Full Text PDF

Introduction: Sotalol is a beta-adrenoceptor blocking drug with unique physical and pharmacologic properties. Unlike most beta-adrenoceptor blocking drugs, sotalol is amenable to extracorporeal removal and causes QT interval prolongation and ventricular dysrhythmias. These properties have implications for treating sotalol poisoning.

View Article and Find Full Text PDF

Introduction: In this study, a meta-analysis was conducted to investigate the therapeutic effect of Dapagliflozin (DAPA) on animals suffering from myocardial ischemia reperfusion compared to the group that did not receive treatment.

Methods: According to the inclusion and exclusion criteria two researchers performed the primary and secondary screening based on the title abstract and full text. After data extraction, meta-analysis was performed using STATA software.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!