Background: In most radiographic studies of polyethylene wear, investigators have used routine annual radiographs made with the patient in the supine position in order to measure penetration by the femoral head into the polyethylene liner. However, researchers have begun to question the effect of weight-bearing on the position of the head within the acetabular cup and, consequently, the effect of weight-bearing on measurements of penetration by the head. The purpose of the current study was to determine the effect of weight-bearing on the two-dimensional radiographic position of the femoral head within the acetabular cup.

Methods: Thirty-seven patients (forty-seven hips) who had had a total hip arthroplasty had radiographs made at one of two separate institutions. A set of anteroposterior radiographs was made for each patient: one radiograph was made with the patient supine and one was made with the patient upright bearing full weight on the replaced hip. At one of the institutions, a third anteroposterior radiograph was made with the patient in the same upright position but not bearing weight on the replaced hip. All measurements of the two-dimensional position of the head were performed by a single observer with use of a previously published computerized measurement system.

Results: Data from both institutions revealed that measurements of the position of the head on radiographs made with the patient supine were strongly and significantly correlated with measurements of the position of the head on radiographs made with the patient bearing weight (r2>0.93, p<0.001 for both regressions). Examination of the differences between the measurements revealed no bias for one set of measurements to consistently underestimate or overestimate the values derived with use of the other method. Moreover, we found a nearly perfect relationship between the measurements of the position of the head on radiographs made with the patient standing and bearing weight and those on radiographs made with the patient standing but not bearing weight (r2 = 0.97, p<0.001, slope = 0.99, intercept = 0.02 millimeter).

Conclusions: On the basis of these findings, there is no evidence that radiographs must be made with the patient bearing weight in order to accurately measure the position of the femoral head within the polyethylene liner.

Download full-text PDF

Source

Publication Analysis

Top Keywords

radiographs patient
16
position head
16
femoral head
12
patient supine
12
position
8
position femoral
8
head
8
total hip
8
hip arthroplasty
8
head acetabular
8

Similar Publications

Thoracolumbar Fracture: A Natural History Study of Survival Following Injury.

J Bone Joint Surg Am

November 2024

Department of Orthopaedic Surgery, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts.

Background: Fractures of the thoracic and lumbar spine are increasingly common. Although it is known that such fractures may elevate the risk of near-term morbidity, the natural history of patients who sustain such injuries remains poorly described. We sought to characterize the natural history of patients treated for thoracolumbar fractures and to understand clinical and sociodemographic factors associated with survival.

View Article and Find Full Text PDF

Identifying a Reliable Intra-articular Landmark to Avoid Vascular Injury During Transacetabular Screw Fixation: A 3D Computed Tomography Study.

J Am Acad Orthop Surg

September 2024

From the Department of Orthopaedic Surgery, Keck Medical Center of the University of Southern California, Los Angeles, CA (Ihn, Chung, Lovro, Patterson, Christ, and Heckmann), the Department of Orthopaedic Surgery, Mayo Clinic, Rochester, MN (Chen), the Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, PA (Tucker), and the Department of Radiology, Keck Medical Center of the University of Southern California, Los Angeles, CA (White, and Hwang).

Introduction: Vascular injury during acetabular screw fixation is a life-threatening complication of total hip arthroplasty. This study uses three-dimensional computed tomography to (1) measure absolute distance from the external iliac artery (EIA) to the acetabulum, (2) determine available bone stock along the EIA path, and (3) create a novel acetabular vascular risk map.

Methods: A retrospective radiographic study was conducted using three-dimensional CT.

View Article and Find Full Text PDF

Novel pain assessment tool specific for pulp symptoms to aid diagnosis.

Int Endod J

January 2025

Division of Conservative Dentistry and Endodontics, Centre for Dental Education and Research, All India Institute of Medical Sciences, New Delhi, India.

Aim: Although many pain assessment tools exist, none are specific to the relatively unique presentation of pulpal pain. The aim of this study was to develop and validate a novel pain assessment tool based on pulp symptoms.

Methodology: A preliminary list of items best-describing pulpitis was developed based on deductive and inductive approaches and the preliminary tool was piloted (n = 80).

View Article and Find Full Text PDF

Objectives: To translate, cross-culturally adapt and validate the Serbian Ankylosing Spondylitis Quality of Life (ASQoL) questionnaire, e.g. according to the new nomenclature Radiographic-Axial Spondyloarthritis (r-axSpA), and to relate it to disease activity and functional status domains.

View Article and Find Full Text PDF

Scapho-metacarpal dual mobility prosthesis for TMC-1 joint salvage: technical insights.

Arch Orthop Trauma Surg

January 2025

BG Klinikum Unfallkrankenhaus Berlin, Department of Hand-, Replantation- and Microsurgery and Chair of Hand-, Replantation- and Microsurgery, Charité Universitätsmedizin Berlin, Berlin, Germany.

Introduction: Rhizarthrosis, or osteoarthritis of the trapeziometacarpal joint, predominantly affects women over 50, with up to 30% experiencing some degree of arthritis in this joint. Traditional surgical approaches, such as trapeziectomy with ligament reconstruction, can result in some patients in persistent pain or limited functionality. TMC ball-in-socket arthroplasty, with a cup placed in the distal scaphoid, offers a promising alternative to traditional arthrodesis or resection-suspension arthroplasty.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!