The goal of this study was to compare the safety and efficacy of Amuchina 50% solution versus that of povidone-iodine 10% solution for transfer-set change in peritoneal dialysis (PD) patients in a tertiary referral university hospital. The transfer sets were changed using povidone-iodine 10% solution as disinfectant prior to March 1995. Thereafter Amuchina 50% solution was used. Thus data were collected on all the transfer sets changed between January 1993 and August 1997. Amuchina is an electrolytic chloroxidizer. Chlorine is the active ingredient with a pH of 9.5-10.5. Amuchina 50% solution contains chlorine (0.55%). One hundred ninety-nine transfer sets were changed using povidone-iodine 10% solution in 60 PD patients from January 1993 to March 1995. One hundred twenty-eight transfer sets were changed using Amuchina 50% solution in 65 patients from April 1995 to August 1997. The soaking times and nursing times were 2 and 5 minutes, respectively, with Amuchina, and 10 and 20 minutes, respectively, with povidone-iodine 10%. No episode of peritonitis occurred related to transfer-set change in either group. The transfer-set change using Amuchina 50% solution is safe and cost-effective in PD patients.
Download full-text PDF |
Source |
---|
Adv Perit Dial
June 2006
Nephrology Department, Garrahan Pediatric Hospital, Buenos Aires, Argentina.
In a previous communication, we demonstrated that, in the prevention of exit-site infection (ESI) in children, the cleansing agent 50% Amuchina (electrolytic chloroxidizer. Amuchina SpA, Genoa, Italy) is more effective than 10% povidone iodine and as effective as 4% chlorhexidine, but with fewer adverse secondary effects. In the present study, we assessed, in an Argentine pediatric population, whether Amuchina 3% is as effective as Amuchina 50% in preventing ESI in children on chronic peritoneal dialysis.
View Article and Find Full Text PDFJ Biomed Opt
December 2004
University of Milan-Bicocca, Department of Material Sciences, via Cozzi 53, IT-20125 Milan, Italy.
The possibility of a pressure monitoring system by differential pressure sensors to detect contaminant effects on cellular cultures metabolic activity is discussed using Saccharomyces cerevisiae, lymphocyte, and AHH1 cell cultures. Metabolic (aerobic and anaerobic) processes in cells are accompanied by CO(2) production that induces changes in pressure values when cells are cultured in sealed vessels. These values are subsequently converted in voltage units and plotted pressure dynamics versus time.
View Article and Find Full Text PDFAdv Perit Dial
February 2000
Stony Brook Kidney Center (Dialysis Clinic, Inc.), State University of New York, New York, USA.
The goal of this study was to compare the safety and efficacy of Amuchina 50% solution versus that of povidone-iodine 10% solution for transfer-set change in peritoneal dialysis (PD) patients in a tertiary referral university hospital. The transfer sets were changed using povidone-iodine 10% solution as disinfectant prior to March 1995. Thereafter Amuchina 50% solution was used.
View Article and Find Full Text PDFEur J Epidemiol
December 1997
University of Naples Federico II, Department of General and Environmental Physiology, Italy.
The aim of this work was to verify the in vitro virucidal activity of VIRKON No Foam (VIRKON NF) against the HBV DNA, notoriously one the most resistant viruses to heat and to the most commonly used disinfectants. VIRKON NF, an oxidizing agent, has a synergic effect on nucleic acids, polypeptides, glycoproteins, and structural proteins. The experiment was conducted using the serum of a patient with HBsAg+/HBeAg+/HBVDNA+ with a DNA concentration 100 pg/ml.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!