Modified technique of antegrade continence enema using a stapling device.

J Urol

Division of Pediatric Urology, Children's Hospital Medical Center, University of Cincinnati, Ohio, USA.

Published: February 2000

Purpose: We present a stapling technique for constructing an antegrade continence enema (ACE) conduit that is helpful in cases of insufficient appendiceal luminal length or when a concomitant appendiceal Mitrofanoff stoma is required.

Materials And Methods: In 6 patients with a mean age of 9.5 years who required an ACE procedure the cecum was tubularized in continuation with the orthotopic appendix at its base, using a stapling device to construct an ACE conduit. The tubularized segment was imbricated with permanent suture material. In 3 cases appendiceal length after tubularization was sufficient to allow splitting for the concomitant creation of an appendiceal Mitrofanoff stoma.

Results: Patients have been followed an average of 16.5 months. Stomal continence was achieved in all cases as well as reliable catheterization of the appendiceal cecostomy in 6 and the Mitrofanoff conduit in 3.

Conclusions: This modification of the ACE procedure with cecal tubularization in continuation with the appendix using a stapling device is an excellent approach in cases of inadequate appendiceal length. It successfully creates a catheterizable stoma with a reliable flap valve continence mechanism. The complex reconstructive procedure is simplified by eliminating the need to use tapered small intestine, while allowing the creation of a concomitant appendiceal Mitrofanoff stoma as necessary.

Download full-text PDF

Source

Publication Analysis

Top Keywords

stapling device
12
appendiceal mitrofanoff
12
antegrade continence
8
continence enema
8
ace conduit
8
concomitant appendiceal
8
mitrofanoff stoma
8
ace procedure
8
appendiceal length
8
appendiceal
7

Similar Publications

Purpose: To compare the efficac and safety of a dual-blade 20,000 cuts per minute (cpm) vitrectomy probe with a single-blade 10,000 cpm probe for primary rhegmatogenous retinal detachment (RRD).

Study Design: Prospective, randomized controlled clinical trial.

Methods: Evaluations were conducted preoperatively, intraoperatively, and at three months postoperatively.

View Article and Find Full Text PDF

Comparison of outcomes with and without intrastent placement during PMS surgery.

Sci Rep

January 2025

Department of Ophthalmology and Visual Science, Kochi Medical School, Kochi University, Kohasu, Oko-cho, Nankoku City, 783-8505, Kochi, Japan.

To assess the efficacy of using a nylon suture as a stent in the PreserFlo MicroShunt (PMS) lumen to prevent postoperative hypotony, 59 eyes that underwent PMS implantation with follow-up for > 6 months were analyzed. Patients were divided into no intrastenting (NST) and intrastenting (ST) groups, with the ST group subdivided into 9 - 0 nylon suture fully placed (9 F), 9 - 0 nylon suture placement in only half of the lumen (9 H), 10 - 0 nylon suture fully placed (10 F), and 10 - 0 nylon suture placement in only half of the lumen (10 H). The distribution was as follows: 23 eyes in the NST group, 10 in the 9 F group, 9 in the 9 H group, 11 in the 10 F group, and 6 in the 10 H group.

View Article and Find Full Text PDF

Purpose: Small-bites suturing technique for laparotomy closure is now recommended as the standard of care. However, uptake of the practice remains slow. A medical technology called the SutureTOOL has been developed which can facilitate implementation of small-bites.

View Article and Find Full Text PDF

A 64-year-old woman suffered a traumatic rupture of the inferior rectus muscle, with the distal segment unrecoverable. An inferior oblique muscle transposition, augmented with a posterior fixation suture, was performed. This modification may have contributed to the surgical outcome.

View Article and Find Full Text PDF

Purpose: To describe a custom bent 27-gauge needle-guided suture snare technique for scleral fixation of posterior chamber intraocular lenses (PCIOL).

Methods: An 8-0 polypropylene suture was threaded into the lumen of a custom bent 27-gauge needle, and the needle tip was advanced into the eye from the intraocular lens (IOL) fixation point. The suture was threaded through the posterior limbal incision inside the IOL haptic loop and pulled out.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!