The purposes of this study were to retrospectively identify factors associated with decreased use of digital prostheses in workers' compensation recipients 6 months after fitting and to identify characteristics of those individuals who requested and received a second set of prostheses after demonstrating consistent use of the first set. One hundred seventy-eight patients fitted with 281 digital prostheses completed a questionnaire 6 months after fitting. Forty-nine patients (28%) stated they never or occasionally used their prosthesis (low utilization) and 42 (24%) stated they used them more than 4 hours per day (high utilization). One hundred ten patients (62%) reported stump problems; 37 (21%) stated that the problem interfered with the use of the prosthesis. High utilization was associated with nonmanual employment after the injury. Low utilization was associated with male gender, stump problems, and a distal amputation level. Ring finger prostheses were least likely to be used; small finger prostheses, most likely. The country of origin of the patient was not associated with frequency of use. One hundred sixty-one patients had received the prostheses at least 3 years before the end of the study; 45% of these patients had requested and received a second set of prostheses. Women were more likely to request and receive a second set than men. We could not accurately predict future use of digital prostheses. Each case must be evaluated on an individual basis. (J Hand Surg 2000; 25A:80-85.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1053/jhsu.2000.jhsu025a0080 | DOI Listing |
BMJ Case Rep
January 2025
Pneumology, Centre Hospitalier du Valais Romand, Sion, Switzerland.
A woman in her mid-70s presented with worsening dyspnoea, cough and fatigue initially treated for pneumonia. Despite antibiotics, her condition deteriorated, prompting further investigation. Medical history included previous breast implants, the latter of which had ruptured years earlier and was subsequently removed prior to the current presentation.
View Article and Find Full Text PDFHua Xi Kou Qiang Yi Xue Za Zhi
February 2025
Center of Stomatology, Peking University Shenzhen Hospital, Shenzhen 518036, China.
Objectives: This study aims to explore the effect of improving clinical efficiency by replacing traditional impression workflow with centralized digital impression workflow.
Methods: The department of prosthodontics in Center of Stomatology, Peking University Shenzhen Hospital has improved the clinical workflow by replacing the traditional impression made by doctors using impression materials for each patient with a centralized digital impression made by one technician for all patients in the department. This cross-sectional study recorded the chairside time required for impression taking in patients undergoing single posterior zirconia full crown restoration before clinical process improvement; the time required for centralized digital impression production; the comfort level of patients; and the adjacency relationship, occlusal contact relationship, and time required for prostheses adjusting (i.
J Prosthodont
January 2025
Department of Prosthodontics, Jordan University of Science & Technology, Irbid, Jordan.
Purpose: To investigate the feasibility and accuracy (trueness and precision) of facial scanning and virtual patient representation (VPR).
Materials And Methods: One participant was recruited and informed consent was obtained. VPR was performed 30 times with a custom fabricated intraoral scan body (ISB).
BMC Oral Health
January 2025
Department of Oral and Maxillofacial Surgery, Ordu University, Cumhuriyet Yerleşkesi Cumhuriyet Mahallesi, 52200, Ordu, Türkiye, Turkey.
Background: This study evaluates the efficacy of carbon fiber reinforced Polyetheretherketone (Cfr-PEEK) in fixation after sagittal split ramus osteotomy (SSRO) by comparing it with titanium in vitro.
Methods: Twenty-eight sheep hemimandibles were randomly assigned to four groups for SSRO surgery. Fixation was performed with a 4-hole titanium mini plate for 5 mm advancement in Group 1, with a 4-hole Cfr-PEEK mini plate for 5 mm advancement for Group 2, with a 4-hole titanium mini plate for 10 mm advancement for Group 3, and with a 4-hole Cfr-PEEK mini plate for 10 mm advancement for Group 4.
Sci Rep
January 2025
Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Hangzhou, 310000, China.
Direct resin restoration has been widely used to restore the tooth defect for its convenience and minimal invasion. However, the accuracy of the final contour of class II restoration is often unpredictable and quite technique-sensitive due to the limitation of traditional matrix band system. In this study, the authors developed a novel matrix band system using shape memory polymer (SMP), which possessed two reversible shapes including digitized permanent shape to reproduce anatomical proximal contour and programmable temporary shape for clinical practice and reservation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!