Although it is generally assumed that defibrillation becomes more difficult when the duration of VF is prolonged, after a failed defibrillation attempt, there is little information on the defibrillation efficacy of multiple shocks delivered at the same energy. The purpose of this study was to systematically examine the efficacy of a second shock delivered at the same or reversed polarity after a failed first shock. Defibrillation was attempted after 10 seconds of VF in 12 pigs (30-56 kg) using biphasic waveforms and a nonthoracotomy lead system. Shock energy was held constant for the first and second shocks at 50%-90% of the DFT. The second shock was delivered 10 seconds after a failed first shock. First and second shock polarity (first phase) was randomized to (+, +), (+, -), (-, -), (-, +). The incidence of successful defibrillation (for all polarities) was 12.3% for first and 49.1% for second shocks (P < 0.0001). Anodal first shocks had a 17.2% incidence of success as opposed to a 7.4% incidence of success with cathodal first shocks (P = 0.001). Anodal second shocks had a 55.5% incidence of success compared to a 42.7% incidence of success with cathodal second shocks (P = 0.008). There was no significant benefit from polarity reversal after a failed first shock (P = 0.29). In conclusion, less energy is required for successful defibrillation by a second shock after a failed first. The optimal configuration for first and second shocks is with the RV as anode. Polarity reversal of a second shock after a failed first does not affect the probability of second shock success.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1540-8159.1999.tb00407.xDOI Listing

Publication Analysis

Top Keywords

second shock
24
second shocks
20
incidence success
16
failed shock
12
second
11
shock
10
shocks
9
defibrillation
8
failed defibrillation
8
defibrillation attempt
8

Similar Publications

Case 337.

Radiology

January 2025

From the Rush University Medical Center, 1620 W Harrison St, Chicago, IL 60612 (B.H.M., F.G., H.W.A.A., S.G.D., C.D.D., M.A.M.); and University of Texas Health Science Center, Houston, Tex (X.R.Z.).

A 38-year-old previously healthy male patient presented with left-sided facial pain over the prior 5 weeks. He first noticed the pain while washing and applying pressure to his face. The pain was described as shock-like, sharp and shooting, and radiating along the left cheek and temple.

View Article and Find Full Text PDF

Alternate day fasting aggravates atherosclerosis through the suppression of hepatic ATF3 in mice.

Life Metab

June 2024

Department of Endocrinology and Metabolism, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong 510515, China.

Atherosclerosis is the major contributor to cardiovascular mortality worldwide. Alternate day fasting (ADF) has gained growing attention due to its metabolic benefits. However, the effects of ADF on atherosclerotic plaque formation remain inconsistent and controversial in atherosclerotic animal models.

View Article and Find Full Text PDF

Background: Multisystem inflammatory syndrome in neonates (MIS-N) is a rare condition thought to be associated with prenatal exposure to maternal severe acute respiratory syndrome coronavirus 2 infection. This immune-mediated hyperinflammation has been described in neonates with multiorgan dysfunction, including cardiopulmonary, encephalopathy, coagulopathy, and vascular complications. However, renovascular complications in MIS-N are rare.

View Article and Find Full Text PDF

Scrub typhus is an acute febrile illness caused by . It usually presents with high fever, lymphadenopathy, rash, organomegaly and an eschar formation at the site of the bite. Doxycycline is the drug of choice usually showing rapid defervescence, but rarely some cases does not respond.

View Article and Find Full Text PDF

Implications of an Individualized Resuscitation Strategy Using Continuous Rhythm and Physiologic Status Assessment During Ongoing CPR.

Resuscitation

January 2025

Department of Medicine, University of Washington, Seattle, WA; King County Emergency Medical Services, Seattle-King County Department of Public Health, Seattle, WA.

Background: Prior studies have proposed defibrillator biosignal algorithms which characterize cardiac arrest rhythm and physiologic status. We evaluated whether a novel, individualized resuscitation strategy that integrates multiple ECG and impedance-based algorithms could reduce CPR interruptions and better align rescuer actions with patient-specific physiology.

Methods: In a retrospective cohort of ventricular fibrillation out-of-hospital cardiac arrests, observed rescuer actions (rhythm analysis, shock delivery, pulse checks, and drug therapy) were compared to hypothetical actions recommended by the proposed individualized strategy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!