Objectives: This study investigated the feasibility, accuracy and clinical potential of creating polymer hard copies of echocardiographic data using stereolithography.
Background: Three-dimensional (3D) echocardiography has so far been limited by the need to display reconstructed 3D objects on a two-dimensional screen. Thus, tangible stereolithographic polymer models created from echocardiographic data could enhance our spatial perception of cardiac anatomy and pathology.
Methods: Hard-copy replicas of water-filled latex balloon phantoms (n = 7) and porcine liver specimens (n = 12) were generated from echocardiographic images using stereolithography (computerized laser polymerization). In addition, we created 24 models of the mitral valve from 12 transesophageal studies (normal = 6, mitral stenosis n = 4, prolapse/flail leaflet n = 8, annular dilation n = 2, leaflet restriction n = 2 and following mitral valve repair n = 2).
Results: Excellent agreement was found for comparison of volumes (r = 0.98, SEE = 3.46 mm3, mean difference = 0.25 +/- 3.33 mm3) and maximal dimensions (r = 0.99, SEE = 0.16 cm, mean difference = 0.03 +/- 0.16 cm) between phantoms and their corresponding replicas. Visual and tactile examination of mitral valve models by two blinded observers allowed correct depiction of mitral valve anatomy and pathology in all cases.
Conclusions: Stereolithographic modeling of echocardiographic images is feasible and provides tangible polyacrylic models that are true to scale, shape and volume. Such models offer accurate depiction of mitral valve anatomy and pathology in patients studied with transesophageal echocardiography. This technique could have substantial impact on diagnosis, management and preoperative planning in complex cardiovascular disorders.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0735-1097(99)00498-2 | DOI Listing |
Eur J Cardiothorac Surg
January 2025
Department of Thoracic and Cardiovascular Surgery, Korea University Anam Hospital, Korea University College of Medicine, Seoul, Republic of Korea.
Objectives: This study aimed to evaluate the prognostic impact of permanent pacemaker (PPM) implantation within the first year after mitral valve (MV) surgery combined with the Cox-maze procedure, focusing on long-term outcomes, including overall mortality, infective endocarditis (IE), and ischaemic stroke.
Methods: We conducted a retrospective cohort study using data from the National Health Insurance Service (NHIS) in South Korea, identifying 10,127 patients who underwent MV surgery with the Cox-maze procedure between 2005 and 2020. Patients were classified into the PPM and non-PPM groups based on PPM implantation within one year postoperatively.
Echocardiography
February 2025
Department of Obstetrics and Gynecology, Ministry of Health, Ankara City Hospital, Ankara, Turkey.
Purpose: To investigate fetal cardiac functions and remodeling in pregnancies conceived via in vitro fertilization (IVF).
Methods: This prospective case-control study included 40 singleton IVF pregnancies and 46 uncomplicated control pregnancies at 28-36 weeks of gestation. The IVF group consisted of pregnancies applied to the outpatient clinic, excluding those with anatomical or chromosomal abnormalities.
BMJ Case Rep
January 2025
Cardiology, East Cheshire NHS Trust, Macclesfield, UK.
Non-bacterial thrombotic endocarditis (NBTE) is characterised by sterile vegetations on heart valves and often emerges in hypercoagulable states like malignancy. It is frequently underdiagnosed and only comes to light during postmortem examination. Early diagnosis and treatment with anticoagulation can help lower mortality.
View Article and Find Full Text PDFEur Heart J
January 2025
Department of Cardiology, Keio University School of Medicine, Tokyo, Japan.
Background And Aims: The association between periprocedural change in tricuspid regurgitation (TR) and outcomes in patients undergoing mitral transcatheter edge-to-edge repair (M-TEER) is unclear. This study aimed to examine the prognostic value of TR before and after M-TEER.
Methods: Patients in the OCEAN-Mitral registry were divided into four groups according to baseline and post-procedure echocardiographic assessments: no TR/no TR (no TR), no TR/significant TR (new-onset TR), significant TR/no TR (normalized TR), and significant TR/significant TR (residual TR) (all represents before/after M-TEER).
Circ Cardiovasc Interv
January 2025
Department of Cardiac Surgery, University of Michigan, Ann Arbor (G.A.).
Background: The association, if any, between the transmitral mean pressure gradient (TMPG) after mitral transcatheter edge-to-edge repair and 1-year mortality is controversial in patients undergoing mitral transcatheter edge-to-edge repair with the MitraClip system. We sought to estimate the association between intraoperatively measured residual mitral regurgitation (rMR) and TMPG and 1-year mortality among patients undergoing mitral transcatheter edge-to-edge repair to facilitate decisions on additional devices.
Methods: In patients with severe secondary (functional) MR, we analyzed registry data using generalized estimating equations.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!