Background: The pericardial bovine prosthesis Pericarbon should offer some advantages in comparison with the former generations, because its development is focused on solving previous problems and resulted in the variation of the pericardial fixation method, of valve structure and of stent coating. This hypothesis was evaluated through a retrospective follow-up.

Methods: Between 1985 and 1989, 78 Pericarbon prostheses O 29 were implanted in mitral position by the same surgeon. All patients received warfarin for the first three months to maintain an International Normalized Ratio between 2.5 and 3.5; after which they received antiaggregant therapy indefinitely. With an average follow-up period of 7.34 years for a total of 573 patient-years, we evaluated perioperative and late mortality, late morbidity (thromboembolic and haemorrhagic events, reoperations, primary tissue failures, endocarditic events) and patient clinical conditions.

Results: Perioperative mortality was 1.28% (1/78), late mortality was 11.6% (9/77) with 5 valve-related deaths. 5-year survival was 93% and 10-year survival 97%. Fifteen patients required reoperation for prosthetic replacement, fourteen for primary tissue failure. There were ten minor thromboembolic events, one major event, one haemorrhage and one prosthetic endocarditis (the last two with patient exitus). After 10 years (75% of patients were in New York Heart Association class I-II.

Conclusions: Besides the known better haemodynamic performance, Pericarbon bioprosthesis seems to present a survival and redofreedom curve comparable to the best porcine prosthesis, with less incidence of endocarditis, thromboembolic events and prosthesis leakage.

Download full-text PDF

Source

Publication Analysis

Top Keywords

mitral position
8
late mortality
8
primary tissue
8
thromboembolic events
8
bovine pericardial
4
pericardial bioprosthesis
4
bioprosthesis mitral
4
position ten-year
4
ten-year follow-up
4
follow-up background
4

Similar Publications

Introduction We aimed to assess whether partial hepatectomy has an influence on conventional and speckle tracking parameters on echocardiography in living liver donors in the early postoperative period. Methods This study was a retrospective study to investigate the cardiac effects of liver donation after the transplant operation in a high-volume liver transplant center. Ninety living liver donors were included in the study.

View Article and Find Full Text PDF

Background: The transcatheter edge-to-edge repair (TEER) technique, facilitated by the MitraClip device, is a minimally invasive intervention designed for high-risk patients with mitral regurgitation (MR). This study conducts a retrospective analysis of death events associated with MitraClip implantation over a ten-year decade, utilizing data from the FDA's Manufacturer and User Facility Device Experience (MAUDE) database to evaluate trends in safety outcomes.

Methods: A comprehensive search of the publicly accessible MAUDE database was conducted to retrieve reports of deaths and injuries related to MitraClip implantation from October 2013 to September 2023.

View Article and Find Full Text PDF

Reintervention after aortic root replacement with allograft, xenograft, and stented bioprosthetic valves.

Cardiovasc Revasc Med

December 2024

Division of Cardiac Surgery, Department of Cardiothoracic Surgery, University of Pittsburgh, Pittsburgh, PA, United States of America; Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, PA, United States of America. Electronic address:

Background: There has been a significant increase in the utilization of non-mechanical valves in the aortic position over time. However, details in reinterventions after aortic root replacement (ARR) with non-mechanical prosthesis were limited in the literature, despite the potential importance of reinterventions in the lifetime management of aortic valve disease.

Methods: This is a single-center retrospective study, identifying all patients who underwent ARR with allograft, xenografts, and stented bioprosthetic valved conduit from 2010 to 2020.

View Article and Find Full Text PDF

Quantification of valvular regurgitation by transthoracic 3D high pulse repetition frequency Doppler echocardiography.

Eur Heart J Imaging Methods Pract

July 2024

Department of Circulation and Medical Imaging, Faculty of Medicine and Health Science, Norwegian University of Science and Technology (NTNU), Prinsesse Kristinas gate 3, Trondheim 7030, Norway.

Aims: To improve quantification of valvular regurgitation, a 3D high-pulse repetition frequency Doppler (3D HPRFD) method was developed for regurgitant volume (RVol) estimation from transthoracic echocardiography (TTE). Although successfully applied and in selected clinical cases, a systematic clinical validation of 3D HPRFD has not been published. Hence, our aims were to investigate (i) feasibility of 3D HPRFD and (ii) correlation between 3D HPRFD and RVol estimates obtained by the 2D proximal isovelocity surface area (PISA) method and cardiac magnetic resonance (CMR) in patients with either aortic regurgitation (AR) or mitral regurgitation (MR).

View Article and Find Full Text PDF

Transjugular transcatheter edge-to-edge mitral valve repair in a patient with functional mitral regurgitation: a case report.

Eur Heart J Case Rep

January 2025

Department of Cardiovascular Medicine, Sendai Kousei Hospital, 1-20 Tsutsumidori-amamiya, Aoba Ward, Sendai, Miyagi 9810914, Japan.

Article Synopsis
  • The transcatheter edge-to-edge mitral valve repair (M-TEER) using the MitraClip system is usually done via the transfemoral approach, but the transjugular approach can be a viable alternative when the former isn't possible.
  • A 57-year-old man with heart failure and severe functional mitral regurgitation could not undergo the transfemoral approach due to an occluded inferior vena cava, leading to the decision to use the transjugular technique instead.
  • The procedure was successful with no complications, significantly reducing the patient's mitral regurgitation, and he showed sustained improvement a year later.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!