Background: The pericardial bovine prosthesis Pericarbon should offer some advantages in comparison with the former generations, because its development is focused on solving previous problems and resulted in the variation of the pericardial fixation method, of valve structure and of stent coating. This hypothesis was evaluated through a retrospective follow-up.
Methods: Between 1985 and 1989, 78 Pericarbon prostheses O 29 were implanted in mitral position by the same surgeon. All patients received warfarin for the first three months to maintain an International Normalized Ratio between 2.5 and 3.5; after which they received antiaggregant therapy indefinitely. With an average follow-up period of 7.34 years for a total of 573 patient-years, we evaluated perioperative and late mortality, late morbidity (thromboembolic and haemorrhagic events, reoperations, primary tissue failures, endocarditic events) and patient clinical conditions.
Results: Perioperative mortality was 1.28% (1/78), late mortality was 11.6% (9/77) with 5 valve-related deaths. 5-year survival was 93% and 10-year survival 97%. Fifteen patients required reoperation for prosthetic replacement, fourteen for primary tissue failure. There were ten minor thromboembolic events, one major event, one haemorrhage and one prosthetic endocarditis (the last two with patient exitus). After 10 years (75% of patients were in New York Heart Association class I-II.
Conclusions: Besides the known better haemodynamic performance, Pericarbon bioprosthesis seems to present a survival and redofreedom curve comparable to the best porcine prosthesis, with less incidence of endocarditis, thromboembolic events and prosthesis leakage.
Download full-text PDF |
Source |
---|
Introduction We aimed to assess whether partial hepatectomy has an influence on conventional and speckle tracking parameters on echocardiography in living liver donors in the early postoperative period. Methods This study was a retrospective study to investigate the cardiac effects of liver donation after the transplant operation in a high-volume liver transplant center. Ninety living liver donors were included in the study.
View Article and Find Full Text PDFBMC Cardiovasc Disord
January 2025
Department of Cardiology, Peking University International Hospital, Life Park Road No.1, Life Science Park of Zhongguancun, Chang Ping District, Beijing, 102206, China.
Background: The transcatheter edge-to-edge repair (TEER) technique, facilitated by the MitraClip device, is a minimally invasive intervention designed for high-risk patients with mitral regurgitation (MR). This study conducts a retrospective analysis of death events associated with MitraClip implantation over a ten-year decade, utilizing data from the FDA's Manufacturer and User Facility Device Experience (MAUDE) database to evaluate trends in safety outcomes.
Methods: A comprehensive search of the publicly accessible MAUDE database was conducted to retrieve reports of deaths and injuries related to MitraClip implantation from October 2013 to September 2023.
Cardiovasc Revasc Med
December 2024
Division of Cardiac Surgery, Department of Cardiothoracic Surgery, University of Pittsburgh, Pittsburgh, PA, United States of America; Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, PA, United States of America. Electronic address:
Background: There has been a significant increase in the utilization of non-mechanical valves in the aortic position over time. However, details in reinterventions after aortic root replacement (ARR) with non-mechanical prosthesis were limited in the literature, despite the potential importance of reinterventions in the lifetime management of aortic valve disease.
Methods: This is a single-center retrospective study, identifying all patients who underwent ARR with allograft, xenografts, and stented bioprosthetic valved conduit from 2010 to 2020.
Eur Heart J Imaging Methods Pract
July 2024
Department of Circulation and Medical Imaging, Faculty of Medicine and Health Science, Norwegian University of Science and Technology (NTNU), Prinsesse Kristinas gate 3, Trondheim 7030, Norway.
Aims: To improve quantification of valvular regurgitation, a 3D high-pulse repetition frequency Doppler (3D HPRFD) method was developed for regurgitant volume (RVol) estimation from transthoracic echocardiography (TTE). Although successfully applied and in selected clinical cases, a systematic clinical validation of 3D HPRFD has not been published. Hence, our aims were to investigate (i) feasibility of 3D HPRFD and (ii) correlation between 3D HPRFD and RVol estimates obtained by the 2D proximal isovelocity surface area (PISA) method and cardiac magnetic resonance (CMR) in patients with either aortic regurgitation (AR) or mitral regurgitation (MR).
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
Department of Cardiovascular Medicine, Sendai Kousei Hospital, 1-20 Tsutsumidori-amamiya, Aoba Ward, Sendai, Miyagi 9810914, Japan.