Impact of electrical cable insulating oil on the mineralisation of [1-(14)C]glucose in soil.

FEMS Microbiol Lett

Department of Environmental Science, Institute of Environmental and Natural Sciences, Lancaster University, Lancaster, UK.

Published: January 2000

Subsurface high voltage electric cables are commonly insulated using dodecylbenzene in combination with mineral oil. This work assessed the impact of increasing concentrations of cable insulating oil (0-10% dry weight) on soil microbial respiration as determined by mineralisation of [1-(14)C]glucose (11 microg C g(-1) soil). Acute impact was assessed from 0 days to 21 days, and chronic impact was assessed after 300 days. This study found that cable insulating oil increased respiratory activity of soil microflora. The extent of impact was found to depend on both oil concentration and the length of oil-soil contact time. Following acute exposure (21-days oil-soil contact time), it was found that oil concentrations up to 1% promoted a significant (P<0.05) increase in the extent of [1-(14)C]glucose mineralisation to (14)CO(2) relative to the control. In contrast, higher concentrations of cable insulating oil (5% and 10%) promoted no significant (P0.05) increase in the extent of [1-(14)C]glucose mineralisation to (14)CO(2) relative to the control. Following chronic exposure (300-days oil-soil contact time), the extent of mineralisation was greater at all oil concentrations applied relative to the control. For oil concentrations up to and including 1%, there was a decrease in the extent of elevation in mineralisation relative to the values after 21-days exposure. At higher oil concentrations, namely 5% and 10%, the extent of elevation in mineralisation was comparable with that after 21-days oil-soil contact time. We suggest that the increase in mineralisation of glucose indicates that cable insulating oil is a readily available carbon source to the carbon-limited soil microflora.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1574-6968.2000.tb08923.xDOI Listing

Publication Analysis

Top Keywords

cable insulating
12
insulating oil
12
mineralisation [1-14c]glucose
8
impact assessed
8
oil-soil contact
8
contact time
8
oil
6
impact
5
impact electrical
4
electrical cable
4

Similar Publications

Photonic axion insulator.

Science

January 2025

Division of Physics and Applied Physics, School of Physical and Mathematical Sciences, Nanyang Technological University, Singapore, Singapore.

Axions, hypothetical elementary particles that remain undetectable in nature, can arise as quasiparticles in three-dimensional crystals known as axion insulators. Previous implementations of axion insulators have largely been limited to two-dimensional systems, leaving their topological properties in three dimensions unexplored in experiment. Here, we realize an axion insulator in a three-dimensional photonic crystal and probe its topological properties.

View Article and Find Full Text PDF

Cross-linked polyethylene (XLPE) is applied in most advanced high-voltage direct-current (HVDC) power cable insulations, which are produced via dicumyl peroxide (DCP) technology. The electrical conductivity of insulation material can be increased by cross-linking byproducts from the DCP process. Hence, currently much attention is being paid to a new process to produce cross-linking byproduct-free XLPE.

View Article and Find Full Text PDF

Radar-Terahertz-Infrared Compatible Stealth Coaxial Silver Nanowire@Carbon Nano-Cable Aerogel.

Angew Chem Int Ed Engl

January 2025

Center for Bioinspired Science and Technology, Hangzhou International Innovation Institute, Beihang University, Hangzhou, 311115.

Achieving multi-spectrum compatible stealth in radar-terahertz-infrared bands with robust performance has great prospects for both military and civilian applications. However, the progress of materials encounters substantial challenges due to the significant variability in frequency coupling properties across different electromagnetic wave bands. Here, this work presents the design of a multi-scale structure and fabricates a lightweight aerogel (silver nanowire@carbon, AgNW@C) consisting of a regular coaxial nano-cable, with silver nanowire as the core and amorphous-graphitized hybrid carbon as the outer-layer.

View Article and Find Full Text PDF

Cable termination is an important part of energy transmission in high-speed trains, and it is also a weak link in the insulation. It is important to determine the insulation status of cable terminals by the detection results of partial discharge signals, but the partial discharge signals in the field test circuit are mixed with a large amount of external corona interference, which affects the detection accuracy. This paper proposes a signal recognition model that incorporates Stockwell transform (ST) and 2DCNN, which in combination with wavelet noise reduction can achieve a high-precision classification effect for partial discharge and corona interference with an accuracy rate of up to 98.

View Article and Find Full Text PDF
Article Synopsis
  • Pipe-type cable systems, like HPFF and gas-filled cables, are used for high-voltage underground transmission and involve insulated cables within steel pipes with pressurized fluids or gases for insulation and cooling.
  • Despite being reliable, these systems can develop faults due to insulation wear and environmental factors, making efficient fault localization critical as many circuits age beyond their 40-year design life.
  • A new approach using accelerometers on the pipes to detect fault-induced acoustic signals has been proposed, showing accurate fault pinpointing within centimeters and aligning closely with theoretical values in experiments, presenting a potential improvement for fault localization and grid reliability.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!