This study aims to evaluate the reliability of repeated graded workload treadmill testing (G-test; 2 mph; 0% grade, increasing 2% every 2 min) and to compare the reliability of a constant workload treadmill protocol (C-test; 2 mph; 12% grade) versus the graded workload treadmill protocol in patients with intermittent claudication, studied longitudinally. A clinical trial investigating an orally stable prostacycline derivative that included 330 patients with intermittent claudication was performed. The trial employed three active treatment groups and one placebo group. Because there were no significant inter-group differences at baseline or after treatment, data from all groups were pooled for the evaluation of treadmill test reliability. Treadmill data were obtained from a 2-week run-in phase where three G-tests were performed, as well as from the beginning and the end of a 3-month double-blind phase where a G-test and a C-test were performed in random order. Treadmill test reliability was described through test process-related and between-subject variances and also using variance-derived parameters such as the reliability coefficient (RC) and the relative precision (RP). A higher value for the RC and a lower value for the RP indicate that the test variability is predominantly due to between-subject variance and not to test process-related variance. Estimates of variance were described for both the maximal or absolute claudication distance (ACD) and the initial claudication distance (ICD) with each treadmill test. Reliability estimates are reported for the total study sample and for patients with baseline claudication distances < or =300 feet and >300 feet (approximately < or =100 m; >100 m), as measured with the C-test. The cut-off value was empirically chosen to separate severely diseased from mild to moderately diseased claudicants. Theoretical considerations suggest that reliability measures may differ in these subgroups. With repeated testing during the run-in phase for the measure of ACD, the G-test had an RC of 0.952 and an RP of 21.9%. With the comparison of both test protocols in the entire study population for the measurement of ACD, the G-test had an RC of 0.902 and an RP of 31.3%, while the C-test had an RC of 0.876 and an RP of 35.2%. The results for ICD on the G-test were an RC of 0.809 and an RP of 43.7%, while the C-test had an RC of 0.737 and an RP of 51.3%. The reliability of the ACD measurement for RC and RP was numerically superior to those for the ICD for both protocols. In patients with a baseline ACD < or =300 feet, the RC for ACD on the G-test was 0.827 and the RP was 41.4%. In contrast, on the C-test the RC decreased to 0.250 and the RP increased to 86.6%. These changes in RC and RP were due to a marked decrease in the between-subject variance, demonstrating the inability of the C-test to separate appropriately the different claudication distances in populations with highly limited baseline claudication distances. During a run-in phase, the G-test has excellent test characteristics. During the longitudinal phase of a trial, the reliability of G-tests and C-tests are comparable in the entire study population. However, in patients with low claudication distances, the G-test should be given preference over the C-test.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1358836X9900400406DOI Listing

Publication Analysis

Top Keywords

claudication distances
16
treadmill protocol
12
workload treadmill
12
treadmill test
12
test reliability
12
run-in phase
12
acd g-test
12
reliability
10
reliability treadmill
8
treadmill testing
8

Similar Publications

Objective: This study aimed to assess the effect of home-based exercise interventions on walking performance in patients with peripheral artery disease (PAD) and intermittent claudication (IC).

Design: Systematic review and meta-analysis.

Data Sources: We searched the Medline, Web of Science, Embase, Scopus and Cochrane Library databases to identify randomised controlled trials of patients with PAD and IC published in English up to August 2024.

View Article and Find Full Text PDF

Antegrade femoral puncture Using a Suture-Mediated Closure Device in infrainguinal endovascular interventions.

Ann Vasc Surg

December 2024

Department of Vascular Surgery, IRCCS Sacro Cuore-Don Calabria, Negrar, VR, Italy.

Introduction: ProGlide is a suture-mediated vascular closure device (VCD) indicated for retrograde access closure at the common femoral artery (CFA). However, its off-label use for antegrade and/or superficial femoral artery (SFA) access has become common in many practices. This study evaluated the efficacy and safety of ProGlide for femoral artery access closure in patients undergoing antegrade infrainguinal endovascular procedures.

View Article and Find Full Text PDF

This study included 107 patients with peripheral arterial disease (PAD) undergoing revascularization and aimed to evaluate the effects of body mass index (BMI) on outcomes of quality of life (intermittent claudication questionnaire - ICQ), pain-free walking distance (PFWD), and maximum claudication distance (MCD). The study included 107 patients aged 18-80 years with PAD undergoing revascularization (average age 66±6.7 years; 82% men and 18% women, average BMI 28.

View Article and Find Full Text PDF

Objective: Intermittent claudication (IC) is a common pathology, affecting 4.5% of the UK population, and is associated with significant health burden if disease progresses to chronic limb-threatening ischaemia (CLTI). The natural history of conservatively managed IC remains poorly described, and this study aimed to examine the rate and predictors of progression from IC to CLTI.

View Article and Find Full Text PDF
Article Synopsis
  • Peripheral artery disease (PAD) causes narrowed arteries in the legs, leading to leg pain during walking, which hampers daily activities; supervised exercise can help improve walking ability.
  • This study will compare a cardiovascular rehabilitation (CR) program involving supervised exercise and education with usual care in 66 patients who have recently undergone lower limb revascularisation for PAD.
  • The effectiveness of the CR program will be evaluated based on improvements in walking capacity and quality of life over a 6-week period.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!