Bipolar ventricular far-field signals in the atrium.

Pacing Clin Electrophysiol

Medizinische Universitätsklinik, Innere Medizin III, Homburg, Germany.

Published: November 1999

In an attempt to evaluate the prevalence and predisposing factors of bipolar ventricular far-field oversensing, 57 patients were studied who had a Medtronic dual chamber pacemaker implanted (models 7940: n = 6; 7960i: n = 41; 401: n = 3; 8968i: n = 7) and bipolar atrial leads with a dipole spacing from 8.6 to 60 mm attached to various parts of the atrial wall (lateral/anterior: n = 30; appendage: n = 10; atrial septum: n = 10; floating: n = 7). Median bipolar sensing threshold for P waves was 4.0 mV (2.8-4.0 mV, lower and upper quartile) with standard leads and 0.35 (0.25-1.4) mV with single pass (VDD) devices. At the highest sensitivity available, 43 of 50 DDD pacemakers but only two of seven VDD systems detected intrinsic R waves in the atrium (P < 0.01). Ventricular far-field oversensing occurred at 0.5 mV in 28 (56%) and at 1.0 mV in 16 of 50 DDD units (32%), respectively, and there was one observation in a septal implant at a sensitivity of even 2.8 mV. With ventricular pacing, VDD systems were as susceptible to far-field signals as DDD pacemakers. Outside the postventricular blanking period (100 ms), evoked R waves were detected by 27 of 57 systems (47%) at maximum atrial sensitivity, by 10 (18%) at 0.5 mV, and by 2 (4%) at a setting of 1.0 up to 1.4 mV, respectively. There was no definite superiority of any lead position, there was a trend in favor of the atrial free wall for better intrinsic R wave rejection, but just the opposite was the case for paced ventricular beats. Bipolar signal discrimination tended to be higher with short tip-to-ring spacing (1 7.8 mm) but the difference to larger dipole lengths (30-60 mm) was not significant in terms of the R to P wave ratio and the overall far-field susceptibility. In summary, bipolar ventricular far-field oversensing in the atrium is common with short postventricular blanking times and high atrial sensitivity settings that may be warranted for tachyarrhythmia detection and mode switching. A potentially more discriminant effect of shorter dipole lengths (< or = 10 mm) remains to be tested.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1540-8159.1999.tb00379.xDOI Listing

Publication Analysis

Top Keywords

ventricular far-field
16
bipolar ventricular
12
far-field oversensing
12
far-field signals
8
ddd pacemakers
8
vdd systems
8
postventricular blanking
8
atrial sensitivity
8
dipole lengths
8
bipolar
6

Similar Publications

Article Synopsis
  • The study focuses on distinguishing near-field (NF) and far-field (FF) electrograms (EGMs) to better identify critical areas for treating ventricular tachycardia (VT) during ablation procedures, using a new algorithm for EGM analysis.
  • A multicenter study involving 30 patients was conducted, analyzing a massive dataset of EGMs to compare peak frequencies (PF) in different heart rhythms, revealing significant differences that could aid in pinpointing problematic heart circuits.
  • Results indicated that a low-voltage area PF threshold of ≥200 Hz is effective for identifying VT isthmus, with findings suggesting that chronic amiodarone treatment can lower these PF values, potentially impacting treatment outcomes.
View Article and Find Full Text PDF

Aims: Successful ventricular arrhythmia (VA) ablation requires identification of functionally critical sites during contact mapping. Estimation of the peak frequency (PF) component of the electrogram (EGM) may improve correct near-field (NF) annotation to identify circuit segments on the mapped surface. In turn, assessment of NF and far-field (FF) EGMs may delineate the three-dimensional path of a ventricular tachycardia (VT) circuit.

View Article and Find Full Text PDF

Substrate Mapping for Ventricular Tachycardia Ablation Through High-Density Whole-Chamber Double Extra Stimuli: The S3 Protocol.

JACC Clin Electrophysiol

July 2024

Institut Clínic Cardiovascular, Hospital Clínic, Universitat de Barcelona, Barcelona, Spain; Institut d'Investigacions Biomèdiques August Pi i Sunyer, Barcelona, Spain. Electronic address:

Background: A partial delineation of targets for ablation of ventricular tachycardia (VT) during a stable rhythm is likely responsible for a suboptimal success rate. The abnormal low-voltage near-field functional components may be hidden within the high-amplitude far-field signal.

Objectives: The aim of this study was to evaluate the benefit and feasibility of functional substrate mapping using a full-ventricle S3 protocol and to assess its colocalization with arrhythmogenic conducting channels (CCs) on late gadolinium enhancement cardiac magnetic resonance.

View Article and Find Full Text PDF

Cardiac arrhythmias cause depolarization waves to conduct unevenly on the myocardial surface, potentially delaying local components with respect to a previous beat when stimulated at faster frequencies. Despite the diagnostic value of localizing the distinct local electrocardiogram (EGM) components for identifying regions with decrement-evoked potentials (DEEPs), current software solutions do not perform automatic signal quantification. Electrophysiologists must manually measure distances on the EGM signals to assess the existence of DEEPs during pacing or extra-stimuli protocols.

View Article and Find Full Text PDF

Background: Despite effectiveness of the implantable cardioverter-defibrillator (ICD) in saving patients with life-threatening ventricular arrhythmias (VAs), the temporal occurrence of VA after ICD implantation is unpredictable.

Objective: The study aimed to apply machine learning (ML) to intracardiac electrograms (IEGMs) recorded by ICDs as a unique biomarker for predicting impending VAs.

Methods: The study included 13,516 patients who received Biotronik ICDs and enrolled in the CERTITUDE registry between January 1, 2010, and December 31, 2020.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!