Echocardiographic evaluation for the recognition of intravascular and left atrial appendage thrombus remains a difficult problem. A thrombus-specific ultrasonographic contrast agent has the potential for an alternative approach for their delineation. The aim of this study was to investigate the usefulness of thrombus-specific contrast agent MRX-408A1 for the detection of acute experimentally created intravascular and intracardiac thrombus. In the first study, we created inferior vena cava thrombus in 9 dogs. With the use of fundamental 2-dimensional echocardiography imaging, we recorded images of the inferior vena cava thrombus at baseline (n = 9), with the thrombus-specific contrast agent MRX-408A1 (n = 9), and with nonspecific contrast agent MRX-113 (n = 6). In the second study, we created a left atrial appendage thrombus in 8 dogs. We imaged left atrial appendage thrombus at baseline and during MRX-113 and MRX-408A1 infusion. Thrombus was successfully created in all dogs in study 1 and in 6 of 8 dogs in study 2. MRX-408A1 produced a visually apparent increase in ultrasonographic contrast enhancement of the thrombus in all cases in which thrombus was found on autopsy. In both studies, MRX-408A1 increased the videointensity of the thrombus significantly compared with baseline images and images obtained during MRX-113 infusion. The size of the visually detectable thrombus on the image was also significantly larger during MRX-408A1 infusion than at baseline and during MRX-113 infusion. These data provide in vivo demonstration of the efficacy of a thrombus-specific contrast agent, MRX-408A1, in the detection of acute intravascular and intracardiac thrombus. It has the potential to improve the diagnostic accuracy of ultrasonography for the detection of acute thrombi at various cardiovascular sites in the clinical setting.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0894-7317(99)70096-9DOI Listing

Publication Analysis

Top Keywords

contrast agent
24
left atrial
16
atrial appendage
16
appendage thrombus
16
agent mrx-408a1
16
thrombus
13
ultrasonographic contrast
12
thrombus-specific contrast
12
detection acute
12
intravascular left
8

Similar Publications

Hypointense Findings on Hepatobiliary Phase MR Images.

Radiographics

February 2025

From the Department of Radiology, Division of Abdominal Imaging, Mayo Clinic, 200 1st Street SW, Rochester, MN 55905 (K.C.H., M.L.W., C.L.W., J.F., S.K.V.); Department of Medical Imaging, University of Ottawa, Ottawa, Ontario, Canada (K.C.H.); Department of Medical Imaging, Beaujon University Hospital, Clichy, France (M.R.); HT Medica, Madrid, Spain (A.L.); Department of Radiology, University of Vienna, Vienna, Austria (A.B.S.); Department of Radiology, Sun Yat Sen University, Guangzhou, China (J.W.); and Department of Radiology, Division of Abdominal Imaging, Mayo Clinic, Scottsdale, Ariz (A.C.S.).

Hepatobiliary (HB) contrast agents are increasingly valuable diagnostic tools in MRI, offering a wider range of applications as their clinical use expands. Normal hepatocytes take up HB contrast agents, which are subsequently excreted in bile. This property creates a distinct HB phase providing valuable insights into liver function and biliary anatomy.

View Article and Find Full Text PDF

Image-guided Interventions for Core Muscle Injury and Other Disorders in the Pubic Symphysis.

Radiographics

February 2025

Department of Medical Imaging, The Ottawa Hospital, 501 Smyth Rd, Ottawa, ON, Canada K1H 8L6 (D.V.F., J.L.); Department of Radiology, Radiation Oncology and Medical Physics, Faculty of Medicine, University of Ottawa, Ottawa, Ontario, Canada (D.V.F., J.L.); Ottawa Hospital Research Institute, Ottawa, Ontario, Canada (D.V.F., J.L.); and Department of Radiology, St. Paul's Hospital, University of British Columbia, Vancouver, British Columbia, Canada (T.M.).

Formerly termed or , core muscle injury (CMI) encompasses abnormality of structures within the so-called core, which is essentially the hip, abdomen, and pubis. Compared with data on image-guided procedures of other joints, information regarding procedures performed to address CMI and other disorders of the pubic symphysis is lacking. These procedures can be daunting given the joint's small size, surrounding critical neurovascular structures, and three-dimensional anatomy.

View Article and Find Full Text PDF

Chitosan-Functionalized Fluorescent Calcium Carbonate Nanoparticle Loaded with Methotrexate: Future Theranostics for Triple Negative Breast Cancer.

ACS Biomater Sci Eng

January 2025

Nano 2 Micro Material Design Lab, Department of Chemical Engineering and Technology, IIT (BHU), Varanasi 221005, India.

Herein, fluorescent calcium carbonate nanoclusters encapsulated with methotrexate (Mtx) and surface functionalized with chitosan (25 nm) (@Calmat) have been developed for the imaging and treatment of triple-negative breast cancer (TNBC). These biocompatible, pH-sensitive nanoparticles demonstrate significant potential for targeted therapy and diagnostic applications. The efficacy of nanoparticles (NPs) was evaluated in MDA-MB-231 TNBC cell lines.

View Article and Find Full Text PDF

Photon-counting mammography is an emerging modality that allows for spectral imaging and provides a differentiation of material compositions. The development of photon-counting mammography-specific contrast agents has yet to be explored. In this study, the contrast, sensitivity, and organ dose between silver sulfide nanoparticles (AgS-NPs) and a clinically approved iodinated agent (iopamidol) were investigated using a contrast-embedded gradient ramp phantom and a prototype scanner.

View Article and Find Full Text PDF

We report the synthesis of dianionic OCO-supported NHC and MIC complexes of molybdenum and tungsten with the general formula (OCO)MO (OCO = bis-phenolate benzimidazolylidene M = Mo (1-Mo), bis-phenolate triazolylidene M = Mo (2-Mo), M = W (2-W) and bis-phenolate imidazolylidene, M = Mo (3-Mo), W (3-W)). These complexes are tested in the catalytic deoxygenation of nitroarenes using pinacol as a sacrificial oxygen atom acceptor/reducing agent to examine the influence of the carbene and the metal centre in this transformation. The results show that the molybdenum-based triazolylidene complex 2-Mo is by far the most active catalyst, and TOFs of up to 270 h are observed, while the tungsten analogues are basically inactive.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!