Augmented venous drainage improves venous return during minimally invasive cardiac surgery. Two systems to augment drainage are common: in one, a centrifugal pump draws blood from the venous site and pumps it into a venous reservoir. In the other, suction is applied directly to a hard-shell venous reservoir. Both systems overcome the high resistance of the venous cannula when gravity alone is insufficient to provide adequate drainage. Both systems also have shortcomings: in the first approach, the centrifugal pump head can entrap large bubbles, reducing flow and requiring pump stoppage to remove them. Air from the venous line also can be broken up by the centrifugal pump into small bubbles that can pass through the pump head. The direct suction system in the second approach cannot use a closed-bag reservoir, and has the potential to introduce air into the arterial line. We have developed a new venous augmentation system for a closed venous reservoir that provides excellent suction control without the potential to introduce air into the arterial line. Our system replaces the centrifugal pump of the first approach with a roller pump controlled by the Better-Bladder, a new device with FDA 510(k) clearance for long-term pumping. The Better-Bladder is a length of medical tubing, processed to form a thin-walled, enlarged bladder that is sealed within a clear rigid housing. It acts as an in-line reservoir that provides compliance in the venous line and a noninvasive means to measure blood pressure at the pump inlet. The bladder housing can maintain a negative pressure set by the user that controls the degree of gravity drainage. Tests have shown that the Better-Bladder allows for safe, smooth pump control using a roller pump in the venous line.

Download full-text PDF

Source
http://dx.doi.org/10.1177/026765919901400608DOI Listing

Publication Analysis

Top Keywords

centrifugal pump
16
venous
12
roller pump
12
venous reservoir
12
pump
11
venous augmentation
8
pump head
8
potential introduce
8
introduce air
8
air arterial
8

Similar Publications

Extracorporeal Membrane Oxygenation (ECMO) is a modality of extracorporeal life support which allows temporary support in cases of cardiopulmonary failure and cardiogenic shock. This study presents a valveless pump that works by the Liebau effect as a possible pumping system in ECMO circuits, replacing the current roller and centrifugal pumps. For this purpose, a mock circulatory loop emulating the haemodynamic of the right part of the heart has been constructed.

View Article and Find Full Text PDF

In recent decades, electrokinetic handling of microparticles and biological cells found many applications ranging from biomedical diagnostics to microscale assembly. The integration of electrokinetic handling such as dielectrophoresis (DEP) greatly benefits microfluidic point-of-care systems as many modern assays require cell handling. Compared to traditional pump-driven microfluidics, typically used for DEP applications, centrifugal CD microfluidics provides the ability to consolidate various liquid handling tasks in self-contained discs under the control of a single motor.

View Article and Find Full Text PDF

Impeller radial gap is one of important parts within a blood pump, which may affect the hemodynamics and hemocompatibility. In this study, computational fluid dynamics method was performed to evaluate the impact of radial gap sizes. The volume of scalar shear stress decreased with radial gap sizes increasing.

View Article and Find Full Text PDF

Advancement of the Dragon Heart 7-Series for Pediatric Patients With Heart Failure.

Artif Organs

January 2025

BioCirc Research Laboratory, School of Biomedical Engineering, Science, and Health Systems, Drexel University, Philadelphia, Pennsylvania, USA.

Background: Safe and effective pediatric blood pumps continue to lag far behind those developed for adults. To address this growing unmet clinical need, we are developing a hybrid, continuous-flow, magnetically levitated, pediatric total artificial heart (TAH). Our hybrid TAH design, the Dragon Heart (DH), integrates both an axial flow and centrifugal flow blood pump within a single, compact housing.

View Article and Find Full Text PDF

Progress of extracorporeal centrifugal pumps for mechanical circulatory supports.

J Artif Organs

January 2025

Department of Artificial Organs, National Cerebral and Cardiovascular Center, 6-1 Kishibe-Shinmachi, Suita, Osaka, 5648565, Japan.

This review traces the evolution of centrifugal blood pumps in mechanical circulatory support (MCS) systems. Initially met with concerns over blood damage and thrombus formation, centrifugal pumps have become crucial components in ventricular assist devices (VADs) and extracorporeal membrane oxygenation (ECMO) due to their simplified drive mechanisms and adaptability. This paper outlines three generations of centrifugal pump development: first-generation pumps with sealing components, second-generation pumps utilizing pivot bearings, and third-generation pumps employing contactless bearings.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!