The aim of the present study was to investigate the relevance of BTPS (gas at body temperature, atmospheric pressure and saturated with water vapour) conversion of volumes measured with the Vitalograph bellows spirometer. The Vitalograph bellows were tested against a MicroMedical turbine spirometer in extreme temperatures (0-37 degrees C) using a biological control to deliver expired gas at BTPS. Before testing, it was shown that the accuracy of the DairyCard turbine was stable in the relevant temperature range. In a clinical trial six patients with emphysema performed home spirometry b.i.d for 1 month using both the Vitalograph and the turbine. Both the DairyCard and the Vitalograph showed stable accuracy at extreme temperatures when results were reported without any BTPS conversion. These findings were supported by the clinical trial but the conclusions from the clinical setting were weakened by the surprising fact that domiciliary temperatures showed almost no variation. We conclude that the Vitalograph bellows, during dynamic spirometry, measures expired volume at conditions closer to BTPS (than to ATPS) gas at ambient temperature, atmospheric pressure and saturated with water vapour). The use of the BTPS correction based on ambient temperature seems unjustified at office temperatures close to 23 degrees C and at extreme temperatures the conversion of volume will introduce significant over or underestimation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0954-6111(99)90034-3DOI Listing

Publication Analysis

Top Keywords

vitalograph bellows
12
extreme temperatures
12
conversion volumes
8
volumes measured
8
bellows spirometer
8
temperature atmospheric
8
atmospheric pressure
8
pressure saturated
8
saturated water
8
water vapour
8

Similar Publications

Chronic periodontitis and reduced respiratory function.

J Clin Periodontol

March 2019

Centre for Public Health, School of Medicine Dentistry and Biomedical Sciences, Queen's University Belfast, Belfast, UK.

Objective: To investigate whether there was an association between chronic periodontitis (CP) and reduced respiratory function.

Methods: A group of dentate 58- to 72-year-old men in Northern Ireland had a comprehensive periodontal examination. Parallel to the periodontal examination, participants completed questionnaires gathering information on their medical history, social circumstances, demographic background and tobacco use.

View Article and Find Full Text PDF

Objective: The aim of this pilot study was to compare spirometric values obtained with different types of spirometers, spirometers of same type, and repeated measurements with the same spirometer in a pulmonary function laboratory setting.

Results: 12 healthy volunteers performed spirometry on four hot-wire (SensorMedics), two ultrasonic (Spirare) and one wedge-bellows (Vitalograph S) spirometers, according to ATS/ERS (American Thoracic Society/European Respiratory Society) guidelines. Spirometric values were compared using linear mixed models analysis with a random intercept for subjects and a fixed effect for type of spirometer used.

View Article and Find Full Text PDF

Background: Tiotropium is a new long-acting anticholinergic bronchodilator, which is recommended as first-line therapy in the management of chronic obstructive pulmonary disease (COPD). It is currently available in the form of a dry powder inhaler worldwide. Some COPD patients find it difficult to generate inspiratory flow rates of up to 40 l/min, which is required for the drug to reach the airways.

View Article and Find Full Text PDF

There is no current consensus among published guidelines on whether noseclips are required during spirometry testing. This study investigated the effect of noseclips on spirometric measurements in patients with a range of disease. Fifty-two patients (30 male; mean age 58.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!