The aim of the present study was to investigate the relevance of BTPS (gas at body temperature, atmospheric pressure and saturated with water vapour) conversion of volumes measured with the Vitalograph bellows spirometer. The Vitalograph bellows were tested against a MicroMedical turbine spirometer in extreme temperatures (0-37 degrees C) using a biological control to deliver expired gas at BTPS. Before testing, it was shown that the accuracy of the DairyCard turbine was stable in the relevant temperature range. In a clinical trial six patients with emphysema performed home spirometry b.i.d for 1 month using both the Vitalograph and the turbine. Both the DairyCard and the Vitalograph showed stable accuracy at extreme temperatures when results were reported without any BTPS conversion. These findings were supported by the clinical trial but the conclusions from the clinical setting were weakened by the surprising fact that domiciliary temperatures showed almost no variation. We conclude that the Vitalograph bellows, during dynamic spirometry, measures expired volume at conditions closer to BTPS (than to ATPS) gas at ambient temperature, atmospheric pressure and saturated with water vapour). The use of the BTPS correction based on ambient temperature seems unjustified at office temperatures close to 23 degrees C and at extreme temperatures the conversion of volume will introduce significant over or underestimation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0954-6111(99)90034-3 | DOI Listing |
J Clin Periodontol
March 2019
Centre for Public Health, School of Medicine Dentistry and Biomedical Sciences, Queen's University Belfast, Belfast, UK.
Objective: To investigate whether there was an association between chronic periodontitis (CP) and reduced respiratory function.
Methods: A group of dentate 58- to 72-year-old men in Northern Ireland had a comprehensive periodontal examination. Parallel to the periodontal examination, participants completed questionnaires gathering information on their medical history, social circumstances, demographic background and tobacco use.
BMC Res Notes
October 2017
Department of Thoracic Medicine, Haukeland University Hospital, 5021, Bergen, Norway.
Objective: The aim of this pilot study was to compare spirometric values obtained with different types of spirometers, spirometers of same type, and repeated measurements with the same spirometer in a pulmonary function laboratory setting.
Results: 12 healthy volunteers performed spirometry on four hot-wire (SensorMedics), two ultrasonic (Spirare) and one wedge-bellows (Vitalograph S) spirometers, according to ATS/ERS (American Thoracic Society/European Respiratory Society) guidelines. Spirometric values were compared using linear mixed models analysis with a random intercept for subjects and a fixed effect for type of spirometer used.
Respir Med
December 2007
Chest Research Foundation, Marigold Complex, Kalyaninagar, Pune 411014, India.
Background: Tiotropium is a new long-acting anticholinergic bronchodilator, which is recommended as first-line therapy in the management of chronic obstructive pulmonary disease (COPD). It is currently available in the form of a dry powder inhaler worldwide. Some COPD patients find it difficult to generate inspiratory flow rates of up to 40 l/min, which is required for the drug to reach the airways.
View Article and Find Full Text PDFChron Respir Dis
May 2007
PAREXEL International, Northwick Park Hospital, Harrow, UK.
There is no current consensus among published guidelines on whether noseclips are required during spirometry testing. This study investigated the effect of noseclips on spirometric measurements in patients with a range of disease. Fifty-two patients (30 male; mean age 58.