Cyclic pull-out strength of hamstring tendon graft fixation with soft tissue interference screws. Influence of screw length.

Am J Sports Med

Baylor Sports Medicine Institute, Department of Orthopedic Surgery, Baylor College of Medicine, Houston, Texas, USA.

Published: December 1999

Blunt-threaded interference screws used for fixation of hamstring tendons in anterior cruciate ligament reconstructions provide aperture fixation and may provide a biomechanically more stable graft than a graft fixed further from the articular surface. It is unknown if soft tissue fixation strength using interference screws is affected by screw length. We compared the cyclic and time-zero pull-out forces of 7 x 25 mm and 7 x 40 mm blunt-threaded metal interference screws for hamstring graft tibial fixation in eight paired human cadaveric specimens. A four-stranded autologous hamstring tendon graft was secured by a blunt-threaded interference screw into a proximal tibial tunnel with a diameter corresponding to the graft width. Eight grafts were secured with a 25-mm length screw while the other eight paired grafts were secured with a 40-mm length screw. During cyclic testing, slippage of the graft occurred as the force of pull became greater with each cycle until the graft-screw complex ultimately failed. All grafts failed at the fixation site, with the tendon being pulled past the screw. There were no measurable differences in the mean cyclic failure strength, pull-out strength, or stiffness between the two sizes of screws. Although use of the longer screw would make removal technically easier should revision surgery be necessary, it did not provide stronger fixation strength than the shorter, standard screw as had been postulated.

Download full-text PDF

Source
http://dx.doi.org/10.1177/03635465990270061501DOI Listing

Publication Analysis

Top Keywords

interference screws
16
pull-out strength
8
hamstring tendon
8
tendon graft
8
soft tissue
8
screw
8
screw length
8
blunt-threaded interference
8
fixation strength
8
grafts secured
8

Similar Publications

Purpose: To biomechanically evaluate a flat posterior cruciate ligament (PCL) reconstruction utilizing rectangular femoral bone tunnels.

Methods: Eight fresh-frozen human knee specimens were tested in a six-degrees-of-freedom robotic test setup. In each testing step, a force-controlled test protocol was performed, including 89 N posterior tibial translation (PTT) in neutral, internal and external rotation, from 0 to 90° of flexion.

View Article and Find Full Text PDF

Introduction: medial patellofemoral ligament reconstruction (MPFLr) is a common surgical procedure for treating patellar instability. Grafts can be fixed to the femur using a bone-tunnel technique with an interference screw. However, this may lead to femoral tunnel enlargement (FTE) post-operatively.

View Article and Find Full Text PDF

Collateral injuries are usually found in association with cruciate ligament tears. There are multiple techniques to reconstruct the collateral ligaments using autografts and allografts. Conventionally, interference screws are used to fix the graft on the femur, tibia, and fibula.

View Article and Find Full Text PDF

The original LaPrade technique for anatomic reconstruction of the posterolateral corner of the knee uses two separate allografts. More recently, a modification of this technique, using an adjustable-length suspension device with a cortical button for tibial fixation, allows anatomic reconstruction with a single semitendinosus autograft. This modification is of utmost relevance when sources of allograft are not available for multiligament knee reconstruction.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!