The use of capillary high performance liquid chromatography with electrospray mass spectrometry for the analysis of small volume blood samples from serially bled mice to determine the pharmacokinetics of early discovery compounds.

Rapid Commun Mass Spectrom

Department of International Development Support, BioMet, GlaxoWellcome Research and Development, Park Road, Ware, Herts. SG12 0DP, UK.

Published: January 2000

The methodology described demonstrates, for the first time, the feasibility of performing pharmacokinetic studies in the serially bled mouse model to support the early development of discovery compounds. Sample analysis, using capillary high performance liquid chromatography combined with tandem mass spectrometry, has facilitated the achievement of this milestone and has successfully been applied to determine pharmacokinetic information following both intravenous and oral administration of a single discovery compound. The methodologies described demonstrate potential for a reduction in the amount of new chemical entity required to undertake pharmacokinetic studies. Typically, such studies are performed in larger rodents with a significantly increased body mass (ten times in the case of the rat) and therefore it follows that to undertake the same experiment in the mouse would require ten times less compound to effect an equivalent dose. Conventionally, pharmacokinetic studies to obtain both intravenous and oral information, e.g. clearance and half-life, and the resultant bioavailability have been performed using two parallel groups of rodents, collecting blood by exsanguination, separating off the plasma and analysing this using conventional liquid chromatography/tandem mass spectrometry. The use of capillary high performance liquid chromatography (HPLC) has facilitated the analysis of small volume blood samples by increasing the effective sensitivity of the analytical method. Consequently, we have established a protocol for serially bleeding mice thus reducing the number of animals and so further reducing the amount of compound required for such experiments. This paper reports data obtained from collected and processed blood volumes of <20 microL with the subsequent injection of only 1 microL of precipitated extract onto a capillary column.

Download full-text PDF

Source
http://dx.doi.org/10.1002/(SICI)1097-0231(19991215)13:23<2366::AID-RCM800>3.0.CO;2-DDOI Listing

Publication Analysis

Top Keywords

capillary high
12
high performance
12
performance liquid
12
liquid chromatography
12
mass spectrometry
12
pharmacokinetic studies
12
analysis small
8
small volume
8
volume blood
8
blood samples
8

Similar Publications

Capillary vibrating sharp-edge spray ionization (cVSSI) has been used to control the droplet charging of nebulized microdroplets and monitor effects on protein ion conformation makeup as determined by mass spectrometry (MS). Here it is observed that the application of voltage results in noticeable differences to the charge state distributions (CSDs) of ubiquitin ions. The data can be described most generally in three distinct voltage regions: Under low-voltage conditions (<+200 V, LV regime), low charge states (2+ to 4+ ions) dominate the mass spectra.

View Article and Find Full Text PDF

Background: Hemoglobin (Hb) Hekinan is a prevalent α-globin variant frequently missed in thalassemia screening centers using high-performance liquid chromatography (HPLC) or capillary electrophoresis. This study aims to investigate the hematological and molecular characteristics of Hb Hekinan in a large cohort.

Methods: Hb variants were identified using isoelectric focusing (IEF) and HPLC.

View Article and Find Full Text PDF

Background: This study investigates the correlation between the difference in hematocrit (HCT) and serum albumin (ALB) levels (HCT-ALB), muscle tissue oxygen saturation (SmtO2), capillary refill time (CRT), and blood lactate (Lac) with the severity of renal function damage and prognosis in patients with septic shock.

Methods: Conducted from February 2022 to February 2024, this study included 116 septic shock patients treated at the First Affiliated Hospital of Anhui Medical University. Patients were divided into groups based on whether they developed acute kidney injury: 40 patients were included in the acute kidney injury group, and the remaining 76 were placed in the non-kidney injury group.

View Article and Find Full Text PDF

This article experimentally validates a high-sensitivity vector magnetic field (MF) sensor based on two parallel Fabry-Perot interferometers (FPIs). Firstly, two standard single-mode fibers are interposed into a capillary tube to constitute a cantilever beam structure FPI. FPI achieved a high axial strain sensitivity of 15.

View Article and Find Full Text PDF

Whispering-gallery-mode (WGM) microresonators are typically studied for surface (bio)chemical sensing, mainly relying on small refractive index changes occurring within a nanometer range from their walls surface. This high sensitivity, reaching up to 10 refractive index unit (RIU, ∼2.5 nm/RIU and measured at a femtometer resolution) leads to broad ranges of applications, especially for biosensing purposes through the monitoring of molecular binding events.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!