AI Article Synopsis

Article Abstract

The bispectral index, a value derived from the electroencephalogram, has been proposed as a measure of anaesthetic effect. The aim of the present study was to evaluate the bispectral index during midazolam-fentanyl anaesthesia for cardiac surgery for its possible role as a predictor of increases in systolic blood pressure during endotracheal intubation and sternotomy. After institutional approval 15 consenting patients, scheduled for elective cardiac surgery, were selected for the study. Anaesthesia was induced in all patients with a loading dose of fentanyl 7.5-10 micrograms kg-1, midazolam 0.15 mg kg-1 and pancuronium 0.1 mg kg-1. After a further bolus dose of fentanyl 10-12.5 micrograms kg-1 prior to the start of incision and sternotomy, maintenance infusion rates of fentanyl 4-6 micrograms kg-1 h-1 and midazolam 0.1 mg kg-1 h-1 were started and continued through surgery at the discretion of the anaesthetist and guided by the presenting clinical and haemodynamic responses. The control of anaesthesia was never based on the value of the bispectral index. The mean bispectral index value decreased from 95.7 (3.1) at base-line to 59.5 (12.0) after induction of anaesthesia and then remained below 70 throughout surgery. However, there was an important interindividual variability in bispectral index values despite standardized dosages of fentanyl and midazolam. There was no significant correlation between the bispectral index values in the pre-intubation and pre-incision period and the changes in systolic blood pressure during endotracheal intubation and sternotomy, respectively. In conclusion, the large intersubject variability in the bispectral index values should be investigated further in the light of the great variability in the clinical effects of midazolam and fentanyl. The lack of significant correlation between the bispectral index values and the haemodynamic responses suggest that the bispectral index, which is a helpful monitor of anaesthetic depth, is not a very reliable monitor of global anaesthetic adequacy during total intravenous anaesthesia with a combination of midazolam and fentanyl in cardiac surgical patients.

Download full-text PDF

Source
http://dx.doi.org/10.1046/j.1365-2346.1999.00551.xDOI Listing

Publication Analysis

Top Keywords

bispectral values
16
cardiac surgery
12
haemodynamic responses
12
endotracheal intubation
12
micrograms kg-1
12
bispectral
10
anaesthesia cardiac
8
systolic blood
8
blood pressure
8
pressure endotracheal
8

Similar Publications

Objectives: To explore the relationship between the Observer's Assessment of Alertness/Sedation (OAAS) score and the bispectral index (BIS) during propofol titration for general anesthesia induction and analyze the impact of BIS monitoring delay on anesthetic depth assessment.

Methods: This study was conducted among 90 patients (ASA class I-II) undergoing elective surgery under general anesthesia. For anesthesia induction, the patients received propofol titration at the rate of 0.

View Article and Find Full Text PDF

Background: Intraoperative awareness, without explicit recall, occurs after induction of anaesthesia in approximately 10% of persons under 40 yr of age. Most anaesthetic agents minimally suppress the noradrenergic system. We hypothesised that addition of dexmedetomidine, which suppresses noradrenergic activity, may reduce encephalographic (EEG) arousal in response to tracheal intubation; such an effect would lay the foundation for future studies of dexmedetomidine in reducing intraoperative awareness.

View Article and Find Full Text PDF

Introduction: Accurate prognostication in comatose survivors of cardiac arrest is a challenging and high-stakes endeavor. We sought to determine whether internal EEG subparameters extracted by the Bispectral Index (BIS) monitor, a device commonly used to estimate depth-of-anesthesia intraoperatively, could be repurposed to predict recovery of consciousness after cardiac arrest.

Methods: In this retrospective cohort study, we trained a 3-layer neural network to predict recovery of consciousness to the point of command following versus not based on 48 hours of continuous EEG recordings in 315 comatose patients admitted to a single US academic medical center after cardiac arrest (Derivation cohort: N=181; Validation cohort: N=134).

View Article and Find Full Text PDF

Background: We investigated the consistency and accuracy of the Index of Consciousness (IoC) and the Bispectral Index (BIS) in monitoring the sedative effect of ciprofol during the induction of general anesthesia. There is extensive literature that reports good consistency and correlations between the IoC1 and the BIS in reflecting the sedation levels induced by propofol and sevoflurane but not by ciprofol.

Objective: The aim was to compare the consistency and accuracy of the IoC and BIS in monitoring the sedative effect of ciprofol during the induction of general anesthesia.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the relationship between Bispectral Index (BIS) and age-adjusted Minimum Alveolar Concentration (aaMAC) during anesthesia maintenance in adults.
  • Factors such as age, ASA status, and specific anesthetic agents were found to influence BIS readings, indicating that older patients and those given certain drugs showed higher BIS at the same aaMAC.
  • A generalized estimation equation was developed to predict either BIS or aaMAC based on known values, despite significant variances in their relationship.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!