A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Morphologic and functional evaluation of coronary artery bypass conduits. | LitMetric

Morphologic and functional evaluation of coronary artery bypass conduits.

J Magn Reson Imaging

Department of Cardiology, University Hospital VU, 1081 HV Amsterdam, The Netherlands.

Published: November 1999

There is clear evidence in the literature that conventional spin-echo and gradient-echo magnetic resonance imaging (MRI) is capable of assessing patency of coronary artery vein grafts. With more recently introduced breath-hold two-dimensional (2D) and contrast-enhanced 3D techniques, the predictive accuracy has further improved, with sensitivities and specificities in the 90% range. Limitations arise with regard to assessing obstructive disease and evaluating distal segments of sequential grafts, due to insufficient spatial resolution, low signal-to-noise ratio, and cardiac motion. Imaging of arterial grafts is complicated by the metallic clip artifacts. Adding information on graft flow patterns and flow reserve using velocity-encoded cine MRI may help to reduce some of the problems. Clinically, these functional measurements may become of use in non-invasive monitoring of gradually increasing graft narrowing. However, apart from a few exceptions, most patients undergo evaluation of their grafts because they are considered for a re-intervention by angioplasty or coronary artery bypass graft surgery. In these cases information on the status of the native coronary arteries is required. A broader clinical use of MRI in the evaluation of patients with coronary artery bypass grafts may therefore only be expected with further improvement in MR techniques for coronary angiography. J. Magn. Reson. Imaging 1999;10:734-740.

Download full-text PDF

Source
http://dx.doi.org/10.1002/(sici)1522-2586(199911)10:5<734::aid-jmri18>3.0.co;2-4DOI Listing

Publication Analysis

Top Keywords

coronary artery
16
artery bypass
12
coronary
6
grafts
5
morphologic functional
4
functional evaluation
4
evaluation coronary
4
artery
4
bypass conduits
4
conduits clear
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!