Incommensurate frequencies of major vascular regulatory mechanisms.

Can J Physiol Pharmacol

Unité de recherche sur l'hypertension, Centre hospitalier de l'Université Laval, QC, Canada.

Published: April 1999

The dynamic relationship among three major vascular control mechanisms that operate on large fractions of cardiac output: arterial baroreflex and renal and mesenteric autoregulation, was investigated in conscious rats. Wistar and spontaneously hypertensive rats were studied in their home cages 10 days after implantation of pulsed Doppler flow probes. There was an oscillation of blood pressure centered at 0.45 Hz that is associated with operation of arterial baroreflexes. Hindquarters blood flow displayed a featureless, "1/f' power spectrum, in which no autoregulatory or baroreflex signatures could be discerned, although active control of resistance over a wide range of frequencies was evident. The renal pressure - flow transfer function was dominated by an autoregulatory mechanism with a resonance peak at 0.25 +/- 0.01 Hz. In the mesenteric circulation an autoregulatory mechanism was seen with a resonance peak at 0.15 +/- 0.01 Hz and another active mechanism was seen above 0.2 Hz that appeared from its negative admittance phase to be a baroreflex. The center frequencies of mesenteric and renal autoregulation and of the arterial baroreflex were related in a ratio of 1 : 1.7 +/- 0.1 : 3.0 +/- 0.2 (approximately 4:7:12). Such relatively high order ratios can be expected to minimize the possibility of phase locking and (or) entrainment among the various control mechanisms.

Download full-text PDF

Source

Publication Analysis

Top Keywords

major vascular
8
control mechanisms
8
arterial baroreflex
8
autoregulatory mechanism
8
mechanism resonance
8
resonance peak
8
+/- 001
8
incommensurate frequencies
4
frequencies major
4
vascular regulatory
4

Similar Publications

Purpose: Treatment of peripheral artery disease (PAD) in the region below the knee (BTK) is dissatisfying as failure of treated target lesions (TLF) is frequent and diagnostic imaging is often challenging. In the BTK-region metallic drug-eluting stents (mDES) yielded best results concerning primary patency (PP), but also annihilate signal in magnetic resonance angiography (MR-A). A recently introduced non-metallic drug eluting bioresorbable Tyrocore® vascular scaffold (deBVS), that offers an option for re-treatment of lesions due to its full degradation within 3-4 years after placement, was investigated with respect to its compatibility with MR-A to unimpededly depict previously treated target lesions.

View Article and Find Full Text PDF

First-in-Man Study of a Novel Peripheral Plaque Atherectomy Device.

J Clin Hypertens (Greenwich)

January 2025

Department of Vascular Surgery, Xuanwu Hospital, Capital Medical University, Beijing, China.

This first-in-man (FIM) study evaluated the feasibility and safety of a new peripheral plaque atherectomy system in patients with symptomatic lower extremity artery disease (LEAD). Ten patients with symptomatic LEAD (Rutherford class 2-5) were enrolled in a prospective, single-center study from March to April 2024. Patients aged 18-85 years with target lesions showing ≥70% stenosis and reference vessel diameters ≥1.

View Article and Find Full Text PDF

Purpose: Ocular neovascularization is a major cause of blindness. Although fibroblast growth factor-2 (FGF2) has been implicated in the pathophysiology of angiogenesis, the underlying mechanisms remain incompletely understood. The purpose of this study was to investigate the role of FGF2 in retinal neovascularization and elucidate its underlying mechanisms.

View Article and Find Full Text PDF

Background: Neuroendocrine tumors of the thymus (NETT) are rare and malignant tumors that arise in the anterior mediastinum. These tumors can exhibit aggressive behavior and may involve surrounding critical structures, such as the superior vena cava. This case contributes to the literature by presenting a recurrent thymic carcinoma with invasion of major blood vessels, including the superior vena cava, and the complexities involved in its surgical management.

View Article and Find Full Text PDF

A Multi-Scale Computational Model of the Hepatic Circulation Applied to Predict the Portal Pressure After Transjugular Intrahepatic Portosystemic Shunt (TIPS).

Int J Numer Method Biomed Eng

January 2025

Hebei Provincial Key Laboratory of Portal Hypertension and Cirrhosis, Xingtai People's Hospital, Xingtai, China; Department of Radiology, Zhongda Hospital, Medical School, Southeast University, Nanjing, China.

Transjugular intrahepatic portosystemic shunt (TIPS) is a widely used surgery for portal hypertension. In clinical practice, the diameter of the stent forming a shunt is usually selected empirically, which will influence the postoperative portal pressure. Clinical studies found that inappropriate portal pressure after TIPS is responsible for poor prognosis; however, there is no scheme to predict postoperative portal pressure.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!