The effects of centrifugal pumps on blood components other than erythrocytes, namely platelets and their interaction with the coagulation system, are not very well known. In a comparative study with three centrifugal pumps (BioMedicus BP-80, St. Jude Isoflow, and Sarns Delphin) and the Stockert roller pump hemolysis, platelet counts, thromboplastin and partial thromboplastin times, as well as resonance thrombography (RTG) parameters for the assessment of platelet and coagulation function were evaluated in vitro. Normalized indices of hemolysis (NIH) with ACD anticoagulation after 360 minutes were 0.008+/-0.004 (Isoflow), 0.018+/-0.017 (BP-80), 0.085+/-0.051 (Delphin), and 0.049+/-0.010 g/1001 (roller pump). Plasmatic coagulation was activated in all circuits. Platelet function was severely inhibited by the BP-80, indicated by increase in RTG platelet time to 358%+/-150% of initial values compared to 42%+/-29% (Isoflow), 40%+/-20% (Delphin), and 12%+/-10% (roller pump). Fibrin polymerization was affected similarly. The large surface area of the BP-80 leads to an extensive activation of platelets and plasminogen.
Download full-text PDF |
Source |
---|
Ann Biomed Eng
January 2025
BioCardioLab, Fondazione Toscana G. Monasterio, 54100, Massa, Italy.
Extracorporeal Membrane Oxygenation (ECMO) is a modality of extracorporeal life support which allows temporary support in cases of cardiopulmonary failure and cardiogenic shock. This study presents a valveless pump that works by the Liebau effect as a possible pumping system in ECMO circuits, replacing the current roller and centrifugal pumps. For this purpose, a mock circulatory loop emulating the haemodynamic of the right part of the heart has been constructed.
View Article and Find Full Text PDFTransl Pediatr
December 2024
Division of Cardiac Surgery, Department of Surgery, Dentistry, Pediatrics and Gynecology, Verona, Italy.
Background: Fulminant myocarditis (FM) is a potentially lethal disease with a wide spectrum of clinical presentation, thus making the diagnosis hard to depict. In cases where acute circulatory failure occurs venoarterial (VA) extracorporeal membrane oxygenation (ECMO) support is a valid management strategy, especially in the pediatric and adult patients. This study aims to report the results of VA ECMO for FM in our Institution.
View Article and Find Full Text PDFArtif Organs
January 2025
BioCirc Research Laboratory, School of Biomedical Engineering, Science, and Health Systems, Drexel University, Philadelphia, Pennsylvania, USA.
Background: Safe and effective pediatric blood pumps continue to lag far behind those developed for adults. To address this growing unmet clinical need, we are developing a hybrid, continuous-flow, magnetically levitated, pediatric total artificial heart (TAH). Our hybrid TAH design, the Dragon Heart (DH), integrates both an axial flow and centrifugal flow blood pump within a single, compact housing.
View Article and Find Full Text PDFJ Artif Organs
January 2025
Department of Artificial Organs, National Cerebral and Cardiovascular Center, 6-1 Kishibe-Shinmachi, Suita, Osaka, 5648565, Japan.
This review traces the evolution of centrifugal blood pumps in mechanical circulatory support (MCS) systems. Initially met with concerns over blood damage and thrombus formation, centrifugal pumps have become crucial components in ventricular assist devices (VADs) and extracorporeal membrane oxygenation (ECMO) due to their simplified drive mechanisms and adaptability. This paper outlines three generations of centrifugal pump development: first-generation pumps with sealing components, second-generation pumps utilizing pivot bearings, and third-generation pumps employing contactless bearings.
View Article and Find Full Text PDFBioengineering (Basel)
November 2024
Biomedical Research Center, Qatar University, Doha 2713, Qatar.
A comprehensive analysis of in vitro pumps used in cardiovascular research is provided in this review, with a focus on the characteristics of generated flows and principles of flow generations. The cardiovascular system, vital for nutrient circulation and waste removal, generates complex hemodynamics critical for endothelial cell function. Cardiovascular diseases (CVDs) could be caused by the disturbances in these flows, including aneurysms, atherosclerosis, and heart defects.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!