Purpose: Acetazolamide (ACZ)-enhanced single photon emission computed tomography (SPECT) scans can assess both cerebral perfusion and vascular reactivity. Patients with asymptomatic critical carotid artery stenosis were evaluated for cerebral vascular reactivity to determine the effect of extracranial occlusive disease and the effect of carotid endarterectomy (CEA) on intracerebral reactivity.
Methods: In 44 patients with asymptomatic critical carotid artery stenosis, cerebral perfusion and vascular reactivity were assessed before CEA with resting and ACZ-enhanced SPECT scans. All patients had a 70% or greater ipsilateral internal carotid artery stenosis. Preoperative ACZ-enhanced SPECT scans were obtained, usually 5 days before CEA. Postoperative ACZ-enhanced SPECT scans were obtained in 30 patients.
Results: Preoperative SPECT scans were asymmetric, revealing focal (n = 19) or global (n = 15) decreased reactivity in 34 patients (77%). Ten patients had symmetric or normal reactivity. After CEA, 23 patients demonstrated an improvement in reactivity ipsilateral to the side of surgery. The remaining seven patients failed to improve after surgery.
Conclusion: Although all patients had a high-grade internal carotid stenosis, nearly a quarter of the patients had excellent intracerebral collateral flow. Only 71% of patients demonstrated improved intracerebral vasoreactivity after CEA. The lack of improvement in the other patients may have resulted from intracerebral pathology or lack of improvement in the extracranial carotid hemodynamics.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0741-5214(99)70099-6 | DOI Listing |
Int J Cardiovasc Imaging
January 2025
Department of Nuclear Medicine, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany.
Solid-state detector single photon emission computed tomography (SPECT) enables the acquisition of dynamic data for calculation of myocardial blood flow (MBF) and myocardial flow reserve (MFR). Here, we report about our experiences on routine clinical use and robustness using Tc-99 m-sestamibi and Tc-99 m-tetrofosmin. 307 patients underwent dynamic list-mode myocardial perfusion imaging (MPI) and standard static MPI for clinical workup of coronary artery disease on a dedicated cardiac SPECT camera.
View Article and Find Full Text PDFEJNMMI Phys
January 2025
Department of Nuclear Medicine, Division of Life Sciences and Medicine, The First Affiliated Hospital of USTC, University of Science and Technology of China, Hefei, 230001, Anhui, China.
Single photon emission computed tomography (SPECT), a technique capable of capturing functional and molecular information, has been widely adopted in theranostics applications across various fields, including cardiology, neurology, and oncology. The spatial resolution of SPECT imaging is relatively poor, which poses a significant limitation, especially the visualization of small lesions. The main factors affecting the limited spatial resolution of SPECT include projection sampling techniques, hardware and software.
View Article and Find Full Text PDFR I Med J (2013)
February 2025
Alpert Medical School of Brown University, Department of Medicine, Division of Cardiology, Rhode Island Hospital.
Cardiac Positron Emission Tomography (PET) can be used for the assessment of myocardial perfusion. Compared to other cardiac imaging techniques, notably Single Photon Emission Computer Tomography (SPECT), cardiac PET offers superior image resolution, higher accuracy, quantitative measures of myocardial perfusion, lower radiation exposure, and shorter image acquisition time. However, PET tends to be costlier and less widely available than SPECT due to the specialized equipment needed for generating the necessary radiotracers.
View Article and Find Full Text PDFBMC Med Imaging
January 2025
Department of Radiological Sciences, College of Health and Rehabilitation Sciences, Princess Nourah Bint Abdulrahman University, P.O. Box 84428, Riyadh, 11671, Saudi Arabia.
Background: Quantitative molecular imaging via single-photon emission computed tomography-derived standardised uptake value (SPECT/CT-SUV) is used to assess the response of metastatic castration-resistant prostate cancer (mCRPC) patients to targeted radionuclide therapy (TRT) with [Lu]Lu-PSMA. This imaging technique determines the radiopharmaceutical distribution and internal dosimetry in patients who receive TRT. However, there is limited evidence regarding the role of image quantification in monitoring changes induced by [Lu]Lu-PSMA.
View Article and Find Full Text PDFSci Rep
January 2025
Australian Dysautonomia and Arrhythmia Research Collaborative, Adelaide, SA, Australia.
Cognitive dysfunction is frequently reported in individuals with postural orthostatic tachycardia syndrome (POTS), possibly resulting from reduced cerebral blood flow (CBF). We used brain SPECT, an accessible imaging modality that has not been systematically evaluated in this patient group. Retrospective review of participants from our registry was undertaken to identify those who had a brain SPECT performed for investigation of cognitive dysfunction.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!