Objective: To evaluate the reliability and precision of measurement in a new thoracic electrical bioimpedance (TEB) monitor.
Design: Prospective clinical trial using healthy volunteers.
Setting: Military tertiary care teaching hospital.
Subjects: Seventy-five healthy adult volunteers taking no medications.
Interventions: Induction of severe preload reduction using a standardized lower-body negative pressure protocol. Measurement of hemodynamic variables using a TEB monitor before, during, and immediately after application of negative pressure.
Measurements And Results: Seventy-five subjects were enrolled and completed the study. Pulse, blood pressure, stroke index, cardiac index, systolic time ratios (STR), and index of contractility were obtained on all subjects undergoing monitoring with the lower body negative pressure (LBNP) device. Hemodynamic measurements were recorded at 15-sec intervals during incremental application of 0, -10, -20, -40, and -60 mm Hg pressure for 10 mins at each pressure. Maximal tolerated LBNP produced reductions in cardiac, stroke, and contractility indices of 50%, 65%, and 45%, respectively. Pulse and STRs increased 44% and 113%, respectively. The precision of measurement (mean +/- 2 SD) for TEB-derived cardiac and stroke index was 16% and 10%, respectively. Repeatability of measurement was assessed by measuring hemodynamic changes after the abrupt cessation of maximal LBNP. There were significant increases in stroke index (p < .001) and decreases in STRs (p < .001) and pulse (p < .001) 3 mins after LBNP. There was no significant difference between initial and post-LBNP cardiac index (p > .05). Regression equations were applied to scattergram plots of stroke index vs. STRs and index of contractility vs. body mass. The use of these plots allowed elimination of values that appeared to be spurious (stroke index vs. STRs) and also raised the question whether the Sramek-Bemstein equation (stroke volume = left ventricular ejection time x volume of electrically participating tissue x dZ/dt/Zo) fully explained all the factors affecting the TEB waveform.
Conclusions: This new monitor appears to overcome many of the signal processing problems encountered with previous devices. The results clearly demonstrate that accurate and reliable measurement of bioimpedance waveforms is possible and suggest that the monitor is capable of generating precise hemodynamic data across a wide spectrum of hemodynamic alterations. However, the evidence also indicates that new algorithms may be needed to more fully explain the multiple factors affecting this waveform.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/00003246-199909000-00044 | DOI Listing |
Eur J Orthod
December 2024
Department of General Surgery and Medical-Surgical Specialties, Section of Orthodontics, University of Catania, Policlinico Universitario 'Gaspare Rodolico-San Marco', Via Santa Sofia 78, 95123, Catania, Italy.
Background/objectives: Evidence suggests nasal airflow resistance reduces after rapid maxillary expansion (RME). However, the medium-term effects of RME on upper airway (UA) airflow characteristics when normal craniofacial development is considered are still unclear. This retrospective cohort study used computer fluid dynamics (CFD) to evaluate the medium-term changes in the UA airflow (pressure and velocity) after RME in two distinct age-based cohorts.
View Article and Find Full Text PDFNatl Sci Rev
January 2025
State Key Laboratory of Superhard Materials, Jilin University, Changchun 130012, China.
The intentional manipulation of carrier characteristics serves as a fundamental principle underlying various energy-related and optoelectronic semiconductor technologies. However, achieving switchable and reversible control of the polarity within a single material to design optimized devices remains a significant challenge. Herein, we successfully achieved dramatic reversible p-n switching during the semiconductor‒semiconductor phase transition in BiI via pressure, accompanied by a substantial improvement in their photoelectric properties.
View Article and Find Full Text PDFBackground: Juxtaglomerular (JG) cells are sensors that control blood pressure and fluid-electrolyte homeostasis. In response to a decrease in perfusion pressure or changes in the composition and/or volume of the extracellular fluid, JG cells release renin, which initiates an enzymatic cascade that culminates in the production of angiotensin II (Ang II), a potent vasoconstrictor that restores blood pressure and fluid homeostasis. In turn, Ang II exerts a negative feedback on renin release, thus preventing excess circulating renin and the development of hypertension.
View Article and Find Full Text PDFBMC Palliat Care
January 2025
Department of Palliative Medicine, West China School of Public Health and West China Fourth Hospital, Sichuan University, Chengdu, China.
Background: Medical professionals who are engaged in palliative care commonly experience negative emotions resulting from the pain and grief experienced by patients and family members, which results in enormous psychological pressure for professionals, and the risk related to job burnout is significantly greater.
Objective: We aimed to explore the factors influencing job burnout and resilience among palliative care professionals.
Methods: We conducted a qualitative study using semistructured interviews and purposeful sampling methods.
BMC Emerg Med
January 2025
Wellman Center for Photomedicine, Harvard Medical School, Massachusetts General Hospital, CNY149, 13th St, Charlestown, 02129, MA, USA.
Background: The use of emergency tourniquets among military personnel has helped to dramatically reduce battlefield deaths and has recently gained popularity in the civilian sector. Yet, even well-trained individuals can find it difficult to assess proper tourniquet application. Emergency tourniquets are typically deemed sufficiently tightened through cursory visual confirmation or pulse assessment.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!