AI Article Synopsis

Article Abstract

Although interstitial techniques are invasive, they are still the first-line therapeutic modalities for certain types of tumour. They are mainly relevant to tumours that are either inoperable or located so deep that access is complicated. Of the various types of radiation that can be delivered by the interstitial route, ultrasound is the most suitable for deep heating. The study compares the efficacy of two types of applicator with respect to their ability to induce cylindrical zones of coagulation necrosis. The transducer of the first applicator is tubular, whereas the second is plane and can rotate around its axis. Both have an external diameter of 4 mm, are fitted with surface cooling systems and operate at 10.7 MHz and 14 W.cm-2. Comparison involves mathematical modelling of ablated tissue in the targeted area by resolving the bioheat transfer equation (BHTE) using an algorithm based on finite differences. The BHTE gives a temperature value from which the thermal dose can be determined. It is shown that tissue ablation by tubular transducers is slow, and, in consequence, perfusion disturbs the heating pattern: in vivo, irradiation with a tubular transducer lasting 1081 s would be required to ablate a tissue mass with a radius of 8 mm. The corresponding period using a rotating plane transducer with 20 firing angles is only 618 s. The mean exposure time of each shot lasts 31 +/- 7 s. Therefore perfusion would have much less impact in the case of therapy administered using a plane transducer than that using a tubular one.

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF02513303DOI Listing

Publication Analysis

Top Keywords

induce cylindrical
8
cylindrical zones
8
tissue ablation
8
plane transducer
8
theoretical comparison
4
comparison interstitial
4
interstitial ultrasound
4
ultrasound applicators
4
applicators designed
4
designed induce
4

Similar Publications

Thermal Analysis of Electromagnetic Induction Heating for Cylinder-Shaped Objects.

Electrophoresis

January 2025

School of Mechanical and Materials Engineering, Washington State University, Pullman, Washington, USA.

Induction heating is one of the cleanest and most efficient methods for heating materials, utilizing electromagnetic fields induced through AC electric current. This article reports an analytical solution for transient heat transfer in a three-dimensional (3D) cylindrical object under induction heating. A simplified form of Maxwell's equations is solved to determine the heat generation inside the cylinder by calculating the current density distribution within the body.

View Article and Find Full Text PDF

Effect of induced astigmatism on vestibulo-ocular reflex.

Clin Exp Optom

January 2025

Department of Optometry, School of Paramedical and Rehabilitation Sciences, Mashhad University of Medical Sciences, Mashhad, Iran.

Clinical Relevance: The vestibular-ocular reflex stabilises the retinal image and maintains balance during head movement. Astigmatism is one of the common refractive errors that can reduce the quality of visual inputs.

Background: The purpose of this study was to investigate the effect of induced astigmatism on the function of the vestibular-ocular reflex.

View Article and Find Full Text PDF

In the present study, we experimentally investigate the liquid flow induced in a rotating drum (cylindrical tank with a short aspect ratio) aligned horizontally, focusing on the variation in the time-averaged and fluctuating flow structures with different fill ratios. For each fill ratio, controlled by varying the water height, we measure the velocity fields at different cross-sectional planes with particle image velocimetry while varying the rotational speed of the drum. Compared to the condition of a fill ratio of 1.

View Article and Find Full Text PDF

Objectives: Hydroxyapatite (HAp)/collagen (Col) cylinders with laminated collagen layers were implanted into the tibial diaphysis of rats and examined histochemically to clarify how the orientation of HAp and Col bone-like nanocomposite fibers in HAp/Col blocks affects bone resorption and formation.

Methods: HAp/Col fibers were synthesized and compressed into cylindrical blocks to mimic bone nanostructures. These were implanted into the cortical bone cavities of 10-week-old male Wistar rats with fiber bundles parallel to the tibial surface.

View Article and Find Full Text PDF

With their ability to self-assemble spontaneously into well-defined nanoscale morphologies, block copolymer (BCP) thin films are a versatile platform to fabricate functional nanomaterials. An important challenge to wider deployment of BCPs in nanofabrication is combining precise control over the nanoscale domain orientation in BCP assemblies with scalable deposition techniques that are applicable to large-area, curved, and flexible substrates. Here, we show that spray-deposited smooth films of a nominally disordered BCP exhibit latent orientations, which can be prescriptively selected by controlling solvent evaporation during spray casting.

View Article and Find Full Text PDF