The sheep has been the standard laboratory animal for extracorporeal membrane oxygenation (ECMO) research for many years and has proven to be an invaluable and reliable model. However the coagulation system of the sheep is significantly different from humans. These differences make it difficult to investigate the coagulative and inflammatory response to ECMO in sheep. The pig has a very similar coagulation system to humans and therefore makes a more appropriate model. We describe a porcine model of prolonged (48 hours) closed chest venovenous (VV) ECMO that we developed to investigate the inflammatory and coagulative response to different ECMO tubing materials. This model could be used to investigate any aspect of venovenous ECMO.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00002480-199909000-00023DOI Listing

Publication Analysis

Top Keywords

porcine model
8
model prolonged
8
closed chest
8
chest venovenous
8
extracorporeal membrane
8
membrane oxygenation
8
coagulation system
8
response ecmo
8
venovenous ecmo
8
ecmo
5

Similar Publications

Tranexamic acid as an adjunct to resuscitative endovascular balloon occlusion of the aorta does not worsen outcomes in a porcine model of hemorrhage.

Trauma Surg Acute Care Open

January 2025

Expeditionary and Trauma Medicine, Naval Medical Research Unit San Antonio, JBSA-Fort Sam Houston, Texas, USA.

Background: Non-compressible torso hemorrhage (NCTH) represents a leading cause of preventable mortality in trauma. Resuscitative endovascular balloon occlusion of the aorta (REBOA) stabilizes NCTH but may predispose patients to thrombus generation. REBOA must therefore be prospectively evaluated for coagulation risks with concomitant usage of anti-fibrinolytic tranexamic acid (TXA).

View Article and Find Full Text PDF

This study aims to evaluate two of the most commonly used products, the collagen-based patch (Hemopatch) and the micropolysaccharide microspheres powder (Perclot), in the context of stab liver injury in pigs. The objectives of this study were to assess blood loss at various time intervals up to 24 h, survival rates, and mean arterial pressure. The research involved 18 Large-White swine.

View Article and Find Full Text PDF

Pre-established anaesthetic protocols in animal models might unexpectedly interfere with the main outcome of scientific projects and therefore they need to account for the specific research goals. We aimed to optimize the anaesthetic protocol and animal handling strategies in a diabetes-related-study exemplifying how the anaesthetic approach must be adjusted for individual research targets. Aachen minipigs were used as a model to test long-lasting skin glucose sensors for diabetic human patients.

View Article and Find Full Text PDF

African swine fever (ASF) is a highly contagious disease affecting wild and domestic pigs, characterised by severe haemorrhagic symptoms and high mortality rates. Originally confined to Sub-Saharan Africa, ASF virus genotype II has spread to Europe since 2014, mainly affecting Eastern Europe, and progressing through wild boar migrations and human action. In January 2022, the first case of ASF, due to genotype II, was reported in North-western Italy, in a wild boar carcass.

View Article and Find Full Text PDF

New Bipolar Electrosurgical Vessel Sealing Device Provides Improved Performance and Procedural Efficiency.

Med Devices (Auckl)

January 2025

Surgical Research and Development, Surgical Operating Unit, Medtronic, Lafayette, CO, USA.

Purpose: This study compared the performance of the new LigaSure™ XP Maryland Jaw Sealer/Divider (XP Maryland) to that of LigaSure Atlas™ (Atlas) and LigaSure™ Dolphin Tip (Dolphin Tip), two early LigaSure™ (LigaSure) devices characterized by consistent and reliable clinical performance.

Methods: Ex vivo bench testing on porcine renal arteries compared burst pressures, seal times, and rates of sticking, incomplete cuts, and charring between XP Maryland and Atlas and between XP Maryland and Dolphin Tip. In vivo acute testing on a porcine model compared thermal spread, seal times, and rates of hemostasis, sticking, and incomplete cuts between XP Maryland and the two early LigaSure devices.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!