The multielectrode current source (MECS) interstitial hyperthermia (IHT) system uses thermocouple thermometry. To obtain a homogeneous temperature distribution and to limit the number of traumas due to the implanted catheters, most catheters are used for both heating and thermometry. Implications of temperature measurement inside applicators are discussed. In particular, the impact of self-heating of both the applicator and the afterloading catheter were investigated. A one-dimensional cylindrical model was used to compute the difference between the temperature rise inside the applicators (deltaTin) and in the tissue just outside the afterloading catheter (deltaTout) as a function of power absorption in the afterloading catheter, self-heating of the applicator and the effective thermal conductivity of the surrounding tissue. Furthermore, the relative artefact (ERR), i.e. (deltaTin - deltaTout)/deltaTin, was measured in a muscle equivalent agar phantom at different positions in a dual-electrode applicator and for different catheter materials. A method to estimate the tissue temperature by power-off temperature decay measurement inside the applicator was investigated. Using clinical dual-electrode applicators in standard brachytherapy catheters in a muscle-equivalent phantom, deltaTin is typically twice as high as deltaTout. The main reason for this difference is self-heating of the thin feeder wires in the centre of the applicator. The measurement error caused by energy absorption in the afterloading catheter is small, i.e. even for materials with a high dielectric loss factor it is less than 5%. About 5 s after power has been switched off, Tin in the electrodes represents the maximum tissue temperature just before power-off. This delay time (t(delay)) and ERR are independent of Tin. However, they do depend on the thermal properties of the tissue. Therefore, ERR and t(delay) and their stability in perfused tissues have to be investigated to enable a reliable estimation of the tissue temperatures around electrodes in clinical practice.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/44/6/305DOI Listing

Publication Analysis

Top Keywords

afterloading catheter
16
temperature measurement
8
current source
8
interstitial hyperthermia
8
measurement inside
8
inside applicators
8
self-heating applicator
8
absorption afterloading
8
tissue temperature
8
temperature power-off
8

Similar Publications

Sepsis often leads to vasoplegia and a hyperdynamic cardiac state, with treatment focused on restoring vascular tone. However, sepsis can also cause reversible myocardial dysfunction, particularly in the elderly with pre-existing heart conditions. The Surviving Sepsis Campaign Guidelines recommend using dobutamine with norepinephrine or epinephrine alone for patients with septic shock with cardiac dysfunction and persistent hypoperfusion despite adequate fluid resuscitation and stable blood pressure.

View Article and Find Full Text PDF
Article Synopsis
  • - Hemorrhage is the main cause of preventable death in trauma situations, leading to military and civilian advancements in medical practices, particularly through the use of tourniquets to manage extremity bleeding and save lives.
  • - While tourniquets have significantly decreased deaths from bleeding in military settings, noncompressible hemorrhage still poses a major risk, especially before patients receive definitive medical care.
  • - The study explores using a small, disposable pressure monitor during resuscitative endovascular balloon occlusion of the aorta (REBOA) to enhance blood pressure monitoring, facilitate better resuscitation practices, and reduce the need for blood products in extreme environments.
View Article and Find Full Text PDF

Background: Comprehensive quality assurance (QA) for a seamless workflow of high-dose-rate brachytherapy, from imaging to planning and irradiation, is uncommon, and QA of the source dwell position is performed in one- or two-dimensions. Gel dosimetry using magnetic resonance imaging (MRI) is effective in verifying the three-dimensional distribution of doses for image-guided brachytherapy (IGBT). However, MRI scanners are not readily accessible, and MRI scanning is time-consuming.

View Article and Find Full Text PDF
Article Synopsis
  • The study focused on the effects of Impella malrotation on patients in cardiogenic shock, identifying the malrotation in 36% of cases.
  • Findings indicated that those with malrotation experienced significantly worse pulmonary pressures, higher right atrial pressure, and elevated serum lactate levels compared to those without malrotation.
  • The conclusions suggest that Impella malrotation leads to suboptimal left ventricular unloading and aggravated pulmonary and right ventricular conditions, though major adverse outcomes did not significantly differ.
View Article and Find Full Text PDF

Comparison of Pressure vs Volume Overload Ventricular Wall Stress in Patients With Valvular Heart Disease.

J Am Coll Cardiol

August 2024

Heart Centre, The Alfred Hospital, Melbourne, Victoria, Australia; Faculty of Medicine, Nursing and Health Sciences, Monash University, Melbourne, Victoria, Australia; Baker Heart and Diabetes Institute, Melbourne, Victoria, Australia. Electronic address:

Article Synopsis
  • Aortic stenosis (AS) and mitral regurgitation (MR) lead to different changes in the heart's structure, and this study aimed to assess how these conditions affect left ventricular wall stress (LVWS) and cardiac remodeling.
  • The study involved 47 patients with severe AS receiving transcatheter aortic valve replacement (TAVR) and 15 patients with severe MR treated with MitraClip (MC), utilizing tests like a 6-minute walk test (6MWT) and cardiac imaging to evaluate changes in LVWS before and after procedures.
  • Results showed significant decreases in systolic LVWS after TAVR and diastolic LVWS after MC, with a notable correlation indicating that higher LVWS
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!