18.118.33.23918.118.33.23918.118.33.239

A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1036
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3154
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Radiological thickness measurement using a liquid ionization chamber electronic portal imaging device. | LitMetric

We present a method of calibrating the Portal Vision electronic portal imaging device to obtain radiological thickness maps for compensator design. In this method, coefficients are derived to describe the relationship between intensity and thickness for a set of water-equivalent blocks. The effects of four parameters were studied: (a) The dose response of the system was measured and found to be describable by a square-root function. (b) The calibration data and images were taken with a wedge in situ. The effects of using different wedges and different wedge orientations were investigated. The intrinsic accuracy of the accelerator/imager system was found to be 1.9 mm, for both 15 degrees and 30 degrees wedges. Changing the wedge orientation between calibration and imaging and rotating the calibration coefficients accordingly led to an error of 3.5 mm. (c) The variation in detector response with gantry angle was measured and corrected. The residual error in this process was 2.4 mm. (d) The use of a model to correct the effects of imaging with different field sizes was investigated and found to yield a residual error of 2.9 mm. The overall error in image calibrations was approximately 4 mm or 2% in dose. This is considered to be sufficiently small for the intended use of designing compensators for tangential breast irradiation.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/44/6/403DOI Listing

Publication Analysis

Top Keywords

radiological thickness
8
electronic portal
8
portal imaging
8
imaging device
8
residual error
8
thickness measurement
4
measurement liquid
4
liquid ionization
4
ionization chamber
4
chamber electronic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!