Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Efforts to improve the diagnosis of invasive aspergillosis (IA) have been directed towards the detection of fungal antigens, including galactomannan (GM). However, previous evaluations of GM detection have been hampered by a lack of proven cases of IA and by a nonserial study design. This prospective study assessed the diagnostic value of serial screening for circulating GM by using a recently developed sandwich enzyme-linked immunosorbent assay (ELISA) for prolonged-neutropenic and/or steroid-treated patients with hematological disorders. Serum GM levels were monitored twice weekly for 186 consecutive patients at increased risk for IA. The patients were stratified according to the likelihood of IA (proven, probable, possible, and no evidence of IA) by using stringent criteria. Proven IA was defined by characteristic histopathological findings together with a positive culture for Aspergillus species. Autopsy and culture from autopsy specimens was used to verify both positive and negative test results. A total of 2,172 serum samples were tested from 243 episodes (mean, 9 samples/episode). Based on the analysis of 71 patients with confirmed disease status (culture and histology), the sensitivity and specificity of serial GM monitoring were 92.6 and 95.4%, respectively. The positive predictive value was almost 93%, the negative predictive value was 95%, and the efficacy was 94%. False-positive reactions occurred at a rate of nearly 8%, although this figure might have been overestimated. Less than 1% of all tested sera were considered inconclusive. In more than half of the cases, antigenemia was detected before clinical suspicion of IA (median, 6 days before). Serial determination of serum GM by the sandwich ELISA technique is a sensitive tool for the diagnosis of IA in hematological patients at risk. This approach may substantially influence clinical management with regard to preemptive and empirical antifungal therapy.