A central issue in the recovered memory debate is whether it is possible to "remember" a highly emotional incident which never occurred. The present study provided an in-depth investigation of real, implanted, and fabricated (deceptive) memories for stressful childhood events. We examined whether false memories for emotional events could be implanted and, if so, whether real, implanted, and fabricated memories had distinctive features. A questionnaire was sent to participants' parents asking about six highly emotional, stressful events (e.g., serious animal attack) which the participant may have experienced in childhood. Next, across three sessions, interviewers encouraged participants (N = 77) to "recover" a memory for a false event using guided imagery and repeated retrieval attempts. In the first interview, they were asked about one real and one false event, both introduced as true according to their parents. In two subsequent interviews, they were reinterviewed about the false event. Finally, after the third inquiry about the false event, participants were asked to fabricate a memory report. Results indicated that 26% of participants "recovered" a complete memory for the false experience and another 30% recalled aspects of the false experience. Real, implanted, and fabricated memories differed on several dimensions (e.g., confidence, vividness, details, repeated details, coherence, stress). These findings have important implications for the debate over recovered and false memories.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1023/a:1022344128649 | DOI Listing |
Adv Sci (Weinh)
December 2024
Department of Clinical Laboratory, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China.
Monitoring deep wounds is challenging but necessary for high-quality medical treatment. Current methodologies for deep wound monitoring are typically limited to indirect clinical symptoms or costly non-real-time imaging diagnosis. Herein, a smart system is proposed that enables in situ monitoring of deep wounds' status through a semi-implantable device composed of 2 seamlessly connected functional components: 1) the well-designed, microchannel-structured sampling needles that efficiently and conveniently collect samples from deep wound anatomical locations, and 2) the multiplex biochemical testing compartment that facilitates the immediate and persistent detection of multiple biochemical indicators based on a color image processing software accessible to a conventional smartphone.
View Article and Find Full Text PDFVirtual Real
December 2024
Department of Computer Science and Software Engineering, Concordia University, Montreal, Québec Canada.
Epilepsy is a neurological disorder characterized by recurring seizures that can cause a wide range of symptoms. Stereo-electroencephalography (SEEG) is a diagnostic procedure where multiple electrodes are stereotactically implanted within predefined brain regions to identify the seizure onset zone, which needs to be surgically removed or disconnected to achieve remission of focal epilepsy. This procedure is complex and challenging due to two main reasons.
View Article and Find Full Text PDFDent Res J (Isfahan)
November 2024
Department of Periodontology, Dental Student's Research Committee, Isfahan University of Medical Sciences, Isfahan, Iran.
Background: This systematic review and meta-analysis aimed to assess the efficacy of autologous platelet concentrate (APCs) in comparison with coronally-advanced flap alone or in combination with connective tissue graft or other biomaterials or bioactive agents for root coverage (RC) of Miller's Class I and II gingival recession defects by measuring the keratinized mucosa width (KMW).
Materials And Methods: This systematic review and meta-analysis was conducted in accordance with the preferred reporting items for systematic reviews and meta-analysis guidelines. An electronic search of the literature was conducted in PubMed, EMBASE, Scopus, Cochrane, Web of Science, Magiran, Scientific Information Database, and Irandoc for randomized clinical trials (RCTs) that used APCs for RC in their intervention group.
Sci Rep
December 2024
Department of Vascular Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Intraluminal prosthetic graft thrombus (IPT) has been described in case of endovascular aortic pathology repair. This study aimed to assess hemodynamic indicators associated with various anatomical morphologies following endovascular aortic repair (EVAR), aiming to offer further references for the choice of clinical therapy. Six model models (normal, iliac compression, aortic compression, aortoiliac compression, iliac distortion, and long-leg stent) were established based on common anatomical morphologies following EVAR.
View Article and Find Full Text PDFTomography
December 2024
Department of Radiology, University of Massachusetts Medical Center, Worcester, MA 01655, USA.
Objective: Image-guided diagnosis and treatment of lung lesions is an active area of research. With the growing number of solutions proposed, there is also a growing need to establish a standard for the evaluation of these solutions. Thus, realistic phantom and preclinical environments must be established.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!