We examined gender differences in growth hormone (GH) secretion during rest and exercise. Eighteen subjects (9 women and 9 men) were tested on two occasions each [resting condition (R) and exercise condition (Ex)]. Blood was sampled at 10-min intervals from 0600 to 1200 and was assayed for GH by chemiluminescence. At R, women had a 3.69-fold greater mean calculated mass of GH secreted per burst compared with men (5.4 +/- 1.0 vs. 1.7 +/- 0.4 microg/l, respectively) and higher basal (interpulse) GH secretion rates, which resulted in greater GH production rates and serum GH area under the curve (AUC; 1,107 +/- 194 vs. 595 +/- 146 microg x l(-1) x min, women vs. men; P = 0.04). Compared with R, Ex resulted in greater mean mass of GH secreted per burst, greater mean GH secretory burst amplitude, and greater GH AUC (1,196 +/- 211 vs. 506 +/- 90 microg x l(-1) x min, Ex vs. R, respectively; P < 0.001). During Ex, women attained maximal serum GH concentrations significantly earlier than men (24 vs. 32 min after initiation of Ex, respectively; P = 0.004). Despite this temporal disparity, both genders had similar maximal serum GH concentrations. The change in AUC (adjusted for unequal baselines) was similar for men and women (593 +/- 201 vs. 811 +/- 268 microg x l(-1) x min), but there were significant gender-by-condition interactive effects on GH secretory burst mass, pulsatile GH production rate, and maximal serum GH concentration. We conclude that, although women exhibit greater absolute GH secretion rates than men both at rest and during exercise, exercise evokes a similar incremental GH response in men and women. Thus the magnitude of the incremental secretory GH response is not gender dependent.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1152/jappl.1999.87.3.1154 | DOI Listing |
Semi-aerobic Aged-refuse Bioreactor (SAARB) has a good effect on nitrogen removal in leachate, but a strong greenhouse gas (N2O) was generated during the nitrification and denitrification process. The effect of salinity (7-30 g x L(-1)) on the leachate treatment and the N2O production from SAARB system was investigated. Experimental results showed that salinity ranging from 7 to 30 g x L(-1) had no significant effect on COD removal, and the removal efficiency was always more than 85%.
View Article and Find Full Text PDFIn order to investigate the feasibility of deep denitrification and simultaneous removing phthalate esters (PAEs) in the process of reclaimed water treatment uses three-dimensional biofilm-electrode reactor coupled with sulfur autotrophic deep denitrification technology (3BER-S), the technological characteristics and mechanisms were analyzed based on determining the static adsorption capacity of biofilm cultured active carbon fillers in 3BER-S reactor together with the operation results of dynamic denitrification and simultaneous PAEs removing. The results showed that the average adsorption rates of DBP, DEHP were 85.84% and 97.
View Article and Find Full Text PDFZhongguo Zhong Yao Za Zhi
December 2015
An analysis method has been established to test 27 elements (Li, Be, B, Mg, Al, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, As, Sr, Mo, Cd, Sn, Sb, Ba, La, Hg, Pb, Bi) in Maca nationality's medicine with microwave digestion-ICP-MS. Sample solutions were analyzed by ICP-MS after microwave digestion, and the contents of elements were calculated according to their calibration curves, and internal standard method was adopted to reduce matrix effect and other interference effects. The experimental results showed that the linear relations of all the elements were very good; the correlation coefficient (r) was 0.
View Article and Find Full Text PDFBased on indirect competitive immunoassay mechanism, bisphenol A (BPA) was detected by the evanescent wave all-fiber immunosensor previously developed with the detection limit of 0.2 microg x L(-1) and the linear detection range of 0.3-33.
View Article and Find Full Text PDFIn this paper, a method of determination of trace lead in water by UV-Visible diffuse reflectance spectroscopy combined with surfactant and membrane filtration enrichment was proposed. In the NH3 x H2O-NH4Cl buffer solution with pH 8.5, the lead(II) ion would react with dithizone to form the red complex under vigorous stirring, which is hydrophobic and can be enriched by the mixed cellulose ester membrane.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!