Methods for the analysis of PCBs in human food, faeces and serum.

Chemosphere

Institute of Environmental and Natural Science, Environmental Science Department, Lancaster University, UK.

Published: October 1999

A method was developed to determine trace concentrations of a range of individual PCB congeners in biological samples (serum, food and faeces) using GC-MS, to prepare a mass balance of PCBs in humans. A simple method for the analysis of PCBs in human serum, which excluded an extraction step, was first employed. Results indicated that the recoveries of 13C12 PCB spikes were variable. A soxhlet extraction step was added and was found to be efficient and reproducible. A quality control routine and method validation results are presented. In batch tests of the methods presented it was found that the serum analysis method gave within batch mean 13C12 spike recoveries of 98-120% and standard deviations between 6 and 20%. The food/faeces analysis method gave within-batch mean 13C12 spike recoveries of 88-100%, and within batch standard deviations between 4 and 12%. The batch to batch mean recovery for serum analysis was 100%, with an RSD of 9% for high spikes and 10% for low spikes. For food/faeces analysis the batch to batch average recovery was 110%, with an RSD of 5% for high spikes and 9% for low spikes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0045-6535(99)00048-xDOI Listing

Publication Analysis

Top Keywords

analysis pcbs
8
pcbs human
8
food faeces
8
extraction step
8
serum analysis
8
analysis method
8
13c12 spike
8
spike recoveries
8
standard deviations
8
food/faeces analysis
8

Similar Publications

The St. Lawrence Estuary (SLE) beluga () population in Canada is Endangered, and endocrine disrupting contaminants, such as polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs), and other halogenated flame retardants, have been identified as a threat to the recovery of this population. Here, potential impacts of these contaminants on SLE beluga were evaluated by comparing skin transcriptome profiles and biological pathways between this population and a population less exposed to contaminants (Eastern Beaufort Sea) used as a reference.

View Article and Find Full Text PDF

Innovative Method for Reliable Measurement of PEM Water Electrolyzer Component Resistances.

Small Methods

January 2025

Forschungszentrum Juelich GmbH, Institute of Energy Technologies, IET-4, Electrochemical Process Engineering, 52425, Juelich, Germany.

Understanding the sheet resistance of porous electrodes is essential for improving the performance of polymer electrolyte membrane (PEM) water electrolyzers and related technologies. Despite its importance, existing methods often fail to provide reliable and comprehensive data, especially for porous materials with complex morphologies and non-uniform thicknesses. This study introduces a robust and straightforward method for determining the sheet resistance of porous electrodes using a novel probe concept based on industrial printed circuit board (PCB) technology.

View Article and Find Full Text PDF

This study investigates the association between prenatal exposure to dioxin-like polychlorinated biphenyls (DL-PCBs) and glucocorticoid and androgenic hormone levels in cord blood. We analyzed cord blood samples from 500 mother-infant pairs from China (2022-2023), focusing on hormones including cortisol, cortisone, dehydroepiandrosterone (DHEA), and androstenedione. The main analysis revealed significant reductions in cortisol levels with increased exposure to PCB-77 (β = -3.

View Article and Find Full Text PDF

The widespread adoption of electronic devices has enhanced living standards but has also led to a surge in electronic waste (e-waste), creating serious environmental and health challenges. Although various methods exist to recover valuable metals from e-waste, each has notable drawbacks. Among these, chemical leaching with aqua regia is widely used but is both highly corrosive and hazardous.

View Article and Find Full Text PDF

Solid-phase microextraction (SPME) is a fast and simple sample preparation technique that enables the enrichment of analytes, and it is used in combination with other detection techniques to provide accurate and sensitive analytical methods. SPME is widely used in environmental monitoring, food safety, life analysis, biomedicine, and other applications. The extractive coating is the core of the SPME technique, and the properties of the extractive coating greatly influence extraction selectivity and efficiency, as well as the enrichment effect.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!