Corticosteroid withdrawal after orthotopic liver transplantation (OLT) represents an attractive therapeutic option for ameliorating post-OLT metabolic complications, although several reports suggest patients who undergo transplantation for autoimmune hepatitis (AIH) may have a greater incidence of acute and chronic rejection when withdrawn from corticosteroid therapy. The aim of this study is to evaluate the success of corticosteroid withdrawal in patients with AIH after OLT. Twenty-six patients underwent successful OLT for AIH. In 21 of these patients, stable maintenance immunosuppression consisted of cyclosporine (CSA) and prednisone (n = 20) or tacrolimus (TAC) and prednisone (n = 1). In this group, a trial of prednisone withdrawal was initiated when patients were 6 months or more post-OLT, with normal liver function, and receiving an average prednisone dosage of 10 mg/d. Five additional patients treated with either TAC (n = 4) or CSA (n = 1) plus mycophenolate mofetil underwent a 14-day taper of prednisone. Overall, 17 of 25 patients (68%) were successfully withdrawn from corticosteroids, with a mean follow-up of 22 months (range, 1 to 34 months). Of the remaining 8 patients, 5 patients received a lower dosage of prednisone or required prednisone to control inflammatory bowel disease. Only 3 patients remained dependent on prednisone to maintain stable liver allograft function. Withdrawal from 10 to 5 mg of prednisone (n = 21) resulted in four episodes of steroid-responsive and two episodes of steroid-resistant rejection in 3 patients, and 18 of 21 patients (86%) were rejection free. Withdrawal from 5 to 0 mg prednisone (n = 17) resulted in eight episodes of steroid-responsive and no episodes of steroid-resistant rejection in 4 patients; 13 of 17 patients (76%) were rejection free. Of the 5 patients in the 14-day prednisone-taper group, 3 patients had steroid-responsive rejection and 1 patient required OKT3. Seventeen of 21 patients (81%) with AIH were successfully withdrawn from corticosteroids. It is notable that corticosteroid withdrawal was associated with a reduction in serum cholesterol levels, decreased use of antihypertensive agents, and reduced need for insulin or oral hypoglycemic agents. We propose corticosteroid withdrawal should be attempted in patients with underlying AIH who undergo OLT because most will benefit without significantly jeopardizing the liver allograft.

Download full-text PDF

Source
http://dx.doi.org/10.1002/lt.500050514DOI Listing

Publication Analysis

Top Keywords

patients
18
corticosteroid withdrawal
16
withdrawal prednisone
12
patients patients
12
prednisone
11
liver transplantation
8
transplantation autoimmune
8
autoimmune hepatitis
8
withdrawn corticosteroids
8
liver allograft
8

Similar Publications

Importance: States have implemented multiple policies likely to influence opioid prescribing; few national general population studies examine those policies' effects on per-capita opioid morphine milligram equivalents (MME) dispensed.

Objective: To examine state policies' effects on opioids per-capita MMEs dispensed at retail pharmacies.

Design: A longitudinal study of associations between MME per capita and implementation of policy interventions at different times across states.

View Article and Find Full Text PDF

Deep Equilibrium Unfolding Learning for Noise Estimation and Removal in Optical Molecular Imaging.

Comput Med Imaging Graph

January 2025

CAS Key Laboratory of Molecular Imaging, Institute of Automation, Chinese Academy of Sciences, Beijing 100190, China; School of Artificial Intelligence, University of Chinese Academy of Sciences, Beijing 100049, China; National Key Laboratory of Kidney Diseases, Beijing 100853, China. Electronic address:

In clinical optical molecular imaging, the need for real-time high frame rates and low excitation doses to ensure patient safety inherently increases susceptibility to detection noise. Faced with the challenge of image degradation caused by severe noise, image denoising is essential for mitigating the trade-off between acquisition cost and image quality. However, prevailing deep learning methods exhibit uncontrollable and suboptimal performance with limited interpretability, primarily due to neglecting underlying physical model and frequency information.

View Article and Find Full Text PDF

Feasibility of very low iodine dose aortoiliac CT angiography using dual-source photon-counting detector CT.

Eur J Radiol

January 2025

Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA. Electronic address:

Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose.

Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT.

View Article and Find Full Text PDF

Feasibility of on-site CT-FFR analysis on cardiac photon-counting CT in evaluation of hemodynamically significant stenosis in comparison to invasive catheter angiography.

Eur J Radiol

January 2025

Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany. Electronic address:

Objectives: Coronary CT angiography (CCTA) is an excellent tool in ruling out coronary artery disease (CAD) but tends to overestimate especially highly calcified plaques. To reduce diagnostic invasive catheter angiographies (ICA), current guidelines recommend CT-FFR to determine the hemodynamic significance of coronary artery stenosis. Photon-Counting Detector CT (PCCT) revolutionized CCTA and may improve CT-FFR analysis in guiding patients.

View Article and Find Full Text PDF

[F]FDG PET/CT versus Dynamic Contrast-Enhanced CT for the diagnosis of solitary pulmonary Nodule: A Head-to-Head comparative Meta-Analysis.

Eur J Radiol

January 2025

Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Taiyuan, 030032, China; Department of Pulmonary and Critical Care Medicine, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Third Hospital of Shanxi Medical University, Tongji Shanxi Hospital, Taiyuan, 030032, China; Department of Pulmonary and Critical Care Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China. Electronic address:

Purpose: This head-to-head comparative meta-analysis aimed to evaluate the comparative diagnostic efficacy of [F]FDG PET/CT and dynamic contrast-enhanced CT(DCE-CT) for the differentiation between malignant and benign pulmonary nodules.

Methods: An extensive search was conducted in the PubMed, Embase, and Web of Science to identify available publications up to March 23, 2024. Studies were included if they evaluated the diagnostic efficacy of [F]FDG PET/CT and DCE-CT for the characterization of pulmonary nodules.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!