Frequency doubling technology perimetry using a 24--2 stimulus presentation pattern.

Optom Vis Sci

Devers Eye Institute, Discoveries in Sight Research Laboratory, Legacy Health Systems, Portland, Oregon 97210, USA.

Published: August 1999

Purpose: To assess whether smaller targets and a 24-2 stimulus presentation pattern would improve the ability of frequency doubling technology (FDT) perimetry to detect and characterize early glaucomatous visual field loss.

Methods: One hundred normal subjects between the ages of 20 and 85 participated in this study. In addition, 53 patients who either had early glaucomatous visual field loss (n = 23) or were high-risk glaucoma suspects with normal conventional visual fields (n = 30) were evaluated with the commercial version of FDT perimetry (full threshold test) with 17 stimuli (four 10 degrees diameter square targets per quadrant and a central 5 degrees circular target) and a custom version of FDT perimetry using 54 stimuli (4 degrees targets with 6 degrees grid spacing) arranged in a 24-2 stimulus presentation pattern.

Results: The custom FDT test using a 24-2 stimulus presentation pattern had a similar dynamic range, and demonstrated normal aging characteristics and test-retest reliability that were similar to the commercial version of FDT perimetry using 17 larger stimuli. Both FDT tests showed an age-related sensitivity reduction of approximately 0.6 dB per decade, and exhibited an average test-retest reliability of 1 to 1.5 dB. The custom 24-2 FDT perimetry test had a greater variation of sensitivity with eccentricity than the commercial version of FDT perimetry that was probably related to the difference in stimulus size. The custom 24-2 FDT perimetry test had a greater percentage of abnormal test locations than the commercial FDT test for both early glaucomas and high-risk glaucoma suspects.

Conclusions: FDT perimetry can be performed with smaller targets using a presentation pattern that is similar to conventional automated perimetry. In comparison to the commercially available 17 target display, the 24-2 stimulus pattern appears to have modestly higher sensitivity for detection of early glaucomatous loss and provides better characterization of the pattern of visual field loss, but the test takes approximately twice as long.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00006324-199908000-00026DOI Listing

Publication Analysis

Top Keywords

fdt perimetry
32
stimulus presentation
16
presentation pattern
16
24-2 stimulus
16
version fdt
16
early glaucomatous
12
visual field
12
commercial version
12
fdt
11
perimetry
10

Similar Publications

Aims: To demonstrate the relationship of dependency between the thickness of the retinal nerve fiber layer and the functional sensitivity of the retina in healthy young individuals. We also secondarily investigated the relationship between refractive error and mean retinal thickness in the macula.

Material And Methods: The basic cohort contained 30 subjects with an average age of 23.

View Article and Find Full Text PDF
Article Synopsis
  • - The study aimed to estimate the prevalence of glaucoma in Canada using self-reports and various tests like Frequency Doubling Technology Perimetry (FDT), optic nerve measurements, and intraocular pressure data.
  • - Among 2,600-4,100 participants aged 40-79, the findings showed glaucoma prevalence rates ranging from 0.7% to 10.3%, with 16.3% classified as "glaucoma suspects."
  • - Notably, 37.5% of those with definite glaucoma didn't know they had the condition, highlighting the importance of awareness and testing.
View Article and Find Full Text PDF
Article Synopsis
  • The study compared the glaucoma detection accuracy of a new head-mounted binocular visual perimeter screening program (ISP) with that of frequency doubling technology (FDT).
  • It involved 168 eyes (including non-glaucoma and glaucomatous eyes) and found that ISP performed comparably or better than FDT in detecting different stages of glaucoma, with specific AUC values reported.
  • Additionally, ISP required significantly less testing time than FDT, suggesting it could be an effective and efficient tool for glaucoma screening in larger populations.
View Article and Find Full Text PDF

Purpose: To update the literature on peripheral optics and vision following intraocular lens (IOLs) implantation.

Methods: We investigated how current IOLs influence peripheral visual function, peripheral optical quality, and visual perception and performance, in patients following cataract surgery. Peripheral vision is described as vision outside the central foveal region of the eye (beyond 4-5° of eccentricity).

View Article and Find Full Text PDF

Diagnostic Accuracy of Frequency-Doubling Technology and the Moorfields Motion Displacement Test for Glaucoma.

Ophthalmol Glaucoma

May 2023

Francis I. Proctor Foundation, University of California, San Francisco, California; Department of Ophthalmology, University of California, San Francisco, California. Electronic address:

Purpose: Portable perimetric testing could be useful for community-based glaucoma screening programs. Frequency-doubling technology (FDT) and the Moorfields motion displacement test (MDT) are portable perimeters that have shown promise as potential screening tools for glaucoma. This study's goal was to determine the diagnostic accuracy of FDT and MDT for visual field defects and glaucoma.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!