The wear of ultra-high molecular weight polyethylene, the most commonly used bearing material in prosthetic joints, is often substantial, posing a significant clinical problem. For a long time, there has been a need for simple but still realistic wear test devices for prosthetic joint materials. The wear factors produced by earlier reciprocating and unidirectionally rotating wear test devices for polyethylene are typically two orders of magnitude too low, both in water and in serum lubrication. Wear is negligible even under multidirectional motion in water. A twelve-station, circularly translating pin-on-disc (CTPOD) device and a modification of the established biaxial rocking motion hip joint simulator were built. With these simple and inexpensive devices, and with the established three-axis hip joint simulator, realistic wear simulation was achieved. This was due to serum lubrication and to the fact that the direction of sliding constantly changed relative to the polyethylene specimen. The type and magnitude of load was found to be less important. The CTPOD tests showed that the subsurface brittle region, which results from gamma irradiation sterilization of polyethylene in air, has poor wear resistance. Phospholipid and soy protein lubrication resulted in unrealistic wear. The introduction of devices like CTPOD may boost wear studies, rendering them feasible without heavy investment.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1243/0954411991535130 | DOI Listing |
Clin Optom (Auckl)
January 2025
Research Department, Southern College of Optometry, Memphis, TN, USA.
Purpose: To determine the performance of TOTAL30 for Astigmatism (T30fA; Alcon; Fort Worth, TX, USA) contact lenses (CLs) in existing CL wearers who are also frequent digital device users.
Methods: This 1-month, 3-visit study recruited adult, 18- to 40-year-old subjects who were required to use daily digital devices for at least 8 hours per day. All subjects were refit into T30fA CLs.
Acta Clin Croat
December 2023
Department of Orthopedic Surgery, Zagreb University Hospital Center, Zagreb, Croatia.
Total hip arthroplasty (THA) is one of the most successful surgeries. Cemented, uncemented and hybrid methods of implant fixation can be used with different chances for implant survival. There is no consensus on the best fixation method.
View Article and Find Full Text PDFPeerJ
January 2025
College of Engineering, University of Tennessee - Knoxville, TN, United States of America.
Objective: The purpose of this study was to investigate the timing and mode of failure of metallic screw-type suture anchors used to attach artificial tendons to bone in an New Zealand White rabbit model.
Study Design: Metal suture anchors with braided composite sutures of varying sizes (United States Pharmacopeia (USP) size 1, 2, or 5) were used to secure artificial tendons replacing both the Achilles and tibialis cranialis tendons in 12 female New Zealand White rabbits. Artificial tendons were implanted either at the time of (immediate replacement, = 8), or four/five weeks after (delayed replacement, = 4) resection of the biological tendon.
Clin Endocrinol (Oxf)
January 2025
Newcastle Renal Services, Newcastle-upon-Tyne Hospitals NHS Foundation Trust, Freeman Hospital, Newcastle-upon-Tyne, UK.
ChemistryOpen
January 2025
Department of Chemistry, School of Sciences and Humanities, SR University, Warangal, Telangana, 506371, India.
High-entropy alloys (HEAs), containing five or more elements in equal proportions, have recently made significant achievements in materials science due to their remarkable properties, including high toughness, excellent catalytic, thermal, and electrical conductivity, and resistance to wear and corrosion. This study focuses on a HEA composed of 23Fe-21Cr-18Ni-20Ti-18Mn, synthesized via ball milling. The alloy was treated with hydrochloric acid (HCl) to enhance its active surface area.