Coagulation system activation is most commonly assessed by measuring levels of one or more proteins in peripheral blood. Because faulty blood-drawing can cause activation of the coagulation system, artifactual elevations of such markers have been reported. We have therefore investigated the possibility of using randomly collected ('spot') urine samples as a non-invasive means of assessing the state of coagulation system activation. Using a commercially available enzyme-linked immunosorbent assay kit designed to measure plasma levels of fragment 1 + 2, we found immunoreactive fragment 2 in healthy control subjects, and significantly increased levels in diabetic and non-diabetic pregnant subjects, and patients with venous thromboembolism, prostate cancer, and diabetes. Measurements of excretion of immunoreactive fragment 2 are worth further study as an adjunct or alternative to plasma-based assays designed to detect or quantify coagulation system activation.