Background And Objective: Delay is a basic surgical technique used by flap surgeons to improve the blood supply to the distal parts of a random skin flap. The aim of this study was to determine whether a scarless delay can be done by the use of the flash lamp pulsed-dye laser operating at a wavelength of 585 nm.

Study Design/materials And Methods: The pilot study showed that 6 J/cm(2) had a selective photothermolysis effect and therefore was chosen for testing the delay procedure on 15 rats. The percentage of flap necrosis of this group was compared to the results of 15 rats that underwent delay by surgery and 15 rats that were not treated prior to flap surgery (control group).

Results: Laser delay of McFarlane flaps resulted in an average of 15.5% smaller necrotic area compared to the control group (52.7% +/- 14.4% and 68.2% +/- 9.6%, respectively, P < 0.01) and was as effective as surgical delay (53.3% +/- 13.6%).

Conclusions: The results indicate that the flash lamp pulsed-dye laser operating at 585 nm is effective for delaying cutaneous flaps in the rat model.

Download full-text PDF

Source
http://dx.doi.org/10.1002/(sici)1096-9101(1999)25:2<178::aid-lsm12>3.0.co;2-kDOI Listing

Publication Analysis

Top Keywords

flash lamp
12
lamp pulsed-dye
12
pulsed-dye laser
12
laser operating
8
delay
7
comparison flash
4
laser
4
laser 585
4
585 conventional
4
conventional surgery
4

Similar Publications

Time-resolved, rapid-scan Fourier transform infrared (FT-IR) difference spectra have been recorded upon illumination on photosynthetic reaction centers (RCs) from under fixed hydration conditions (relative humidity = 76%). Two different illumination schemes were adopted. Whereas the use of a laser flash (duration: 7 ns) made it possible to follow the kinetics of recombination of the light-induced state PQ to the neutral state PQ, the use of a 20.

View Article and Find Full Text PDF

Impact of Silver Incorporation and Flash-Lamp-Annealing on the Photocatalytic Response of Sputtered ZnO Films.

Nanomaterials (Basel)

September 2024

Instituto de Ciencia de Materiales de Madrid, Consejo Superior de Investigaciones Científicas, Cantoblanco, 28049 Madrid, Spain.

Thin films of silver-doped zinc oxide (SZO) were deposited at room temperature using a DC reactive magnetron co-sputtering technique using two independent Zn and Ag targets. The crystallographic structure, chemical composition and surface morphology of SZO films with different silver concentrations were correlated with the photocatalytic (PC) properties. The crystallization of the SZO films was made using millisecond range flash-lamp-annealing (FLA) treatments.

View Article and Find Full Text PDF

Zinc oxide (ZnO) is a wide bandgap semiconductor that holds significant potential for various applications. However, most of the native point defects in ZnO like Zn interstitials typically cause an n-type conductivity. Consequently, achieving p-type doping in ZnO is challenging but crucial for comprehensive applications in the field of optoelectronics.

View Article and Find Full Text PDF

Unsupervised learning-enabled pulsed infrared thermographic microscopy of subsurface defects in stainless steel.

Sci Rep

June 2024

Nuclear Science and Engineering Division, Argonne National Laboratory, Lemont, IL, 60439, USA.

Metallic structures produced with laser powder bed fusion (LPBF) additive manufacturing method (AM) frequently contain microscopic porosity defects, with typical approximate size distribution from one to 100 microns. Presence of such defects could lead to premature failure of the structure. In principle, structural integrity assessment of LPBF metals can be accomplished with nondestructive evaluation (NDE).

View Article and Find Full Text PDF

To enhance the specificity and sensitivity, cut the cost, and realize joint detection of multiple indicators, an immunoassay system based on the technology of time-resolved fluorescence resonance energy transfer (TR-FRET) was studied. Due to the FRET of the reagent, the donor probe and acceptor probe emitted specific fluorescence to enhance specificity. Long-lifetime specific fluorescence from the acceptor probe was combined with time-resolved technology to enhance sensitivity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!