Background: Elongation (gap formation) at the repair site has been associated with the formation of adhesions and a poor functional outcome after repair of flexor tendons. Our objectives were to evaluate the prevalence of gap formation in a clinically relevant canine model and to assess the effect of gap size on the range of motion of the digits and the mechanical properties of the tendons.

Methods: We performed operative repairs after sharp transection of sixty-four flexor tendons in thirty-two adult dogs. Rehabilitation with passive motion was performed daily until the dogs were killed at ten, twenty-one, or forty-two days postoperatively. Eight tendons ruptured in vivo. In the fifty-six intact specimens, the change in the angles of the proximal and distal interphalangeal joints and the linear excursion of the flexor tendon were measured as a 1.5-newton force was applied to the tendon. The gap at the repair site was then measured, and the isolated tendons were tested to failure in tension.

Results: Twenty-nine tendons had a gap of less than one millimeter, twelve had a gap of one to three millimeters, and fifteen had a gap of more than three millimeters. Neither the time after the repair nor the size of the gap was found to have a significant effect on motion parameters (p > 0.05); however, the ultimate force, repair-site rigidity, and repair-site strain at twenty newtons were significantly affected by these parameters (p < 0.05). Testing of the tendons with a gap of three millimeters or less revealed that, compared with the ten-day specimens, the forty-two-day specimens failed at a significantly (90 percent) higher force (p < 0.01) and had a significantly (320 percent) increased rigidity (p < 0.01) and a significantly (60 percent) decreased strain at twenty newtons (p < 0.05). In contrast, the tensile properties of the tendons that had a gap of more than three millimeters did not change significantly with time.

Conclusions: Our data indicate that, in a dog model involving sharp transection followed by repair, a gap at the repair site of more than three millimeters does not increase the prevalence of adhesions or impair the range of motion but does prevent the accrual of strength and stiffness that normally occurs with time.

Download full-text PDF

Source
http://dx.doi.org/10.2106/00004623-199907000-00010DOI Listing

Publication Analysis

Top Keywords

three millimeters
20
repair site
16
gap three
16
gap
12
gap formation
12
flexor tendons
12
tendons gap
12
formation repair
8
tendons
8
range motion
8

Similar Publications

Ultra-high-resolution brain MRI at 0.55T: bSTAR and its application to magnetization transfer ratio imaging.

Z Med Phys

January 2025

Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland; Department of Radiology, Division of Radiological Physics, University Hospital Basel, Basel, Switzerland.

Purpose: This study aims to evaluate the feasibility of structural sub-millimeter isotropic brain MRI at 0.55 T using a 3D half-radial dual-echo balanced steady-state free precession sequence, termed bSTAR and to assess its potential for high-resolution magnetization transfer imaging.

Methods: Phantom and in-vivo imaging of three healthy volunteers was performed on a low-field 0.

View Article and Find Full Text PDF

Electrochemically converting nitrate (NO ) to value-added ammonia (NH) is a complex process involving an eight-electron transfer and numerous intermediates, presenting a significant challenge for optimization. A multi-elemental synergy strategy to regulate the local electronic structure at the atomic level is proposed, creating a broad adsorption energy landscape in high-entropy alloy (HEA) catalysts. This approach enables optimal adsorption and desorption of various intermediates, effectively overcoming energy-scaling limitations for efficient NH electrosynthesis.

View Article and Find Full Text PDF

The effect of mandibular advancement on pharyngeal airway space in patients with oral squamous cell carcinoma: A monocentric prospective study with computed tomography.

Clin Oral Investig

January 2025

Department of Oral and Maxillofacial Surgery, Klinikum Rechts Der Isar, School of Medicine and Health, Technische Universität München, Ismaninger Str. 22, Munich, D-81679, Germany.

Objectives: The presented study aimed to evaluate the effect of mandibular protrusion with a temporarily applied mandibular advancement device (MAD) on the posterior airway space and to determine a reliable metric constant based on a three-dimensional computed tomography (CT) evaluation.

Materials And Methods: The study population consisted of patients with oral squamous cell carcinoma who were treated at least six months prior to the follow-up CT in supine position. Each patient received an individually adjusted MAD that was temporarily applied with three different protrusion distances (P = 0 mm, P = 4 mm, and P = 8 mm) during follow-up CT.

View Article and Find Full Text PDF

Interocclusal records (IORs) created with bite registration materials (BRMs) accurately reflect the opposing teeth's physiological and anatomical associations in digital and traditional dentistry. This study assessed the linear dimensional accuracy of vinyl polysiloxane-based scannable and transparent BRMs over obligatory clinical time intervals (1, 24, 72, and 168 h/s). A total of 3 scannable [Flexitime Bite, Occlufast CAD, Virtual CADBite] and 3 transparent [Maxill Bite, Charmflex Bite, Defend ClearBite] VPS-based BRMs were divided into 28 subgroups by time interval: 1, 24, 72, and 168 h/s.

View Article and Find Full Text PDF

Three-dimensional multicellular aggregates (MCAs) like organoids and spheroids have become essential tools to study the biological mechanisms involved in the progression of diseases. In cancer research, they are now widely used as in vitro models for drug testing. However, their analysis still relies on tedious manual procedures, which hinders their routine use in large-scale biological assays.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!