The present study evaluates the use of intracoronary velocity measurements by Doppler guidewires for assessing coronary obstructions. In vitro experiments were performed in a flow model using acrylic phantoms of coronary stenoses with different configurations (stenosis area: 56%, 75% and 89%; stenosis length: 1 and 5 mm; stenosis border: tapering or abrupt). Nonpulsatile laminar flow conditions of a test fluid were established at flow rates ranging from 0.5 to 2.0 mL/s to simulate baseline flow and flow after vasodilation. Peak Doppler velocity was measured proximal to, within and distal to the model stenoses. Computer simulations were employed to calculate radial flow profiles with and without a Doppler wire aligned with the vessel center. In 84 in vitro flow experiments, peak Doppler velocity correlated well with the average flow velocity as calculated from the actual flow rate and the vessel's cross-sectional area proximal to (r = 0.98, SEE = 1.4, p < 0.001) and within (r = 0.97, SEE = 16.4, p < 0.001) the stenosis. However, the ratio of calculated average velocity to Doppler-measured peak velocity was significantly different from 0.5, the expected value for a parabolic flow profile (0.76+/-0.08, 0.81+/-0.14; p < 0.001). Acceptable accuracy was found for the Doppler estimation of stenosis severity using the continuity equation (error: 0.9+/-1.2% and -4.6+/-3.5% for stenosis with a length of 5 mm and 1 mm, respectively). Doppler velocity reserve significantly underestimated the true flow reserve for the 56% and 75% stenoses (p < 0.01). Computer simulations demonstrated significant alterations of flow profiles by the wire, which explained the observed underestimation of the true flow reserve by the Doppler velocity reserve. Thus, Doppler guidewire measurements of intracoronary flow velocities are useful to assess the severity of coronary stenoses. However, the in vitro results and computer simulations indicate that guidewires alter the flow profile, so that Doppler velocity reserve may underestimate the true flow reserve.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0301-5629(99)00033-2 | DOI Listing |
Sensors (Basel)
December 2024
Key Laboratory of Science and Technology on Micro-System, Shanghai Institute of Microsystem and Information Technology Chinese Academy of Sciences, Shanghai 200050, China.
Frequency-modulated continuous-wave (FMCW) radar is used to extract range and velocity information from the beat signal. However, the traditional joint range-velocity estimation algorithms often experience significant performances degradation under low signal-to-noise ratio (SNR) conditions. To address this issue, this paper proposes a novel approach utilizing the complementary ensemble empirical mode decomposition (CEEMD) combined with singular value decomposition (SVD) to reconstruct the beat signal prior to applying the FFT-Root-MUSIC algorithm for joint range and velocity estimation.
View Article and Find Full Text PDFMedicina (Kaunas)
November 2024
Imperial College London and Healthcare NHS Trust, London SW 2AZ, UK.
Vascular liver diseases (VLDs) include different pathological conditions that affect the liver vasculature at the level of the portal venous system, hepatic artery, or venous outflow system. Although serological investigations and sometimes histology might be required to clarify the underlying diagnosis, imaging has a crucial role in highlighting liver inflow or outflow obstructions and their potential causes. Cross-sectional imaging provides a panoramic view of liver vascular anatomy and parenchymal patterns of enhancement, making it extremely useful for the diagnosis and follow-up of VLDs.
View Article and Find Full Text PDFHealthcare (Basel)
December 2024
Stichting Cardio Zorg, Kraayveld 5, 1171 JE Badhoevedorp, The Netherlands.
Introduction: Orthostatic intolerance is highly prevalent in patients with myalgic encephalomyelitis/chronic fatigue syndrome (ME/CFS) and is caused by an abnormal reduction in cerebral blood flow (CBF). In healthy controls (HCs), the regulation of CBF is complex and cardiac output (CO) is an important determinant of CBF: a review showed that a 30% reduction in CO results in a 10% reduction in CBF. In previous and separate ME/CFS studies, we showed that CO and CBF decreased to a similar extent during tilt testing.
View Article and Find Full Text PDFFront Med (Lausanne)
December 2024
Department of Medical Ultrasound, Jinshan Hospital of Fudan University, Shanghai, China.
Purpose: Acute fatty liver of pregnancy (AFLP) is a severe complication that can occur in the third trimester or immediately postpartum, characterized by rapid hepatic failure. This study aims to explore the changes in portal vein blood flow velocity and liver function during pregnancy, which may assist in the early diagnosis and management of AFLP.
Methods: This longitudinal study was conducted at a tertiary healthcare center with participants recruited from routine antenatal check-ups.
J Cereb Blood Flow Metab
January 2025
AP-HP, Hôpital Lariboisière, Department of Anaesthesia and Critical Care, Paris, France.
In patients with acute brain injury (ABI), optimizing cerebral perfusion parameters relies on multimodal monitoring. This include data from systemic monitoring-mean arterial pressure (MAP), arterial carbon dioxide tension (PaCO), arterial oxygen saturation (SaO), hemoglobin levels (Hb), and temperature-as well as neurological monitoring-intracranial pressure (ICP), cerebral perfusion pressure (CPP), and transcranial Doppler (TCD) velocities. We hypothesized that these parameters alone were not sufficient to assess the risk of cerebral ischemia.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!