A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Doppler echocardiographic study of left and right ventricular function during dobutamine stress testing in conscious healthy dogs. | LitMetric

Objective: To evaluate left and right ventricular filling and ejection performances by use of Doppler echocardiography in healthy, conscious dogs submitted to dobutamine stress testing.

Animals: 10 unsedated, healthy adult Beagles.

Procedure: Doppler echocardiography was performed during cardiac stress testing on each dog twice at 24-hour intervals. Dobutamine was infused in 10 micrograms/kg of body weight/min incremental dosages, from 12.5 to 42.5 micrograms/kg/min. Duration of each step was 15 minutes. Doppler measurements were recorded at baseline and at each stage of dobutamine infusion, whereas aortic diameter was measured at baseline and at peak dosage by use of two-dimensional echocardiography.

Results: Dobutamine infusion induced a significant increase in velocity time integrals and in peak flow velocities at the aortic, pulmonic, mitral, and tricuspid valves. Acceleration time-to-deceleration time ratio at the aortic wave also was increased significantly. On the other hand, ejection time, acceleration time, and deceleration time at the aortic and pulmonic valves and peak flow velocity of the E wave-to-peak flow velocity of the A wave ratio at the mitral and tricuspid valves decreased significantly during the test. The acceleration time-to-deceleration time ratio at the pulmonic wave was unchanged. A significant, progressive increase in cardiac index also was observed during dobutamine infusion, with a maximal increase of 104% from baseline. This was mediated initially by an increase in stroke index and, at higher dosages, by an increase in heart rate.

Conclusions And Clinical Relevance: Doppler echocardiography performed during dobutamine stress testing may be a reliable method of assessing myocardial function in dogs with cardiovascular disease.

Download full-text PDF

Source

Publication Analysis

Top Keywords

dobutamine stress
12
stress testing
12
doppler echocardiography
12
dobutamine infusion
12
left ventricular
8
echocardiography performed
8
peak flow
8
aortic pulmonic
8
mitral tricuspid
8
tricuspid valves
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!