Electrospray ionization (ESI) tandem mass spectrometry (MS/MS) of peptides in conjunction with automated sequence database searching of the resulting collision-induced dissociation (CID) spectra has become a powerful method for the identification of purified proteins or the components of protein mixtures. The success of the method is critically dependent on the manner by which the peptides are introduced into the mass spectrometer. In this report, we describe a capillary electrophoresis-based system for the automated, sensitive analysis of complex peptide mixtures. The system consists of an ESI-MS/MS instrument, a solid-phase extraction (SPE)-capillary zone electrophoresis (CZE) device for peptide concentration and separation, and an algorithm written in Instrument Control Language (ICL) which modulates the electrophoretic conditions in a data-dependent manner to optimize available time for the generation of high-quality CID spectra of peptides in complex samples. We demonstrate that the data-dependent modulation of the electric field significantly expands the analytical window for each peptide analyzed and that the sensitivity of the SPE-CZE technique is not noticeably altered by the procedure. By applying the technique to the analysis of in vivo phosphorylation sites of endothelial nitric oxide synthase (eNOS), we demonstrate the power of this system for the MS/MS analysis of minor peptide species in complex samples such as phosphopeptides generated by the proteolytic digestion of a large protein, eNOS, phosphorylated at low stoichiometry.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac9813991DOI Listing

Publication Analysis

Top Keywords

data-dependent modulation
8
solid-phase extraction
8
analysis complex
8
complex peptide
8
tandem mass
8
mass spectrometry
8
endothelial nitric
8
nitric oxide
8
oxide synthase
8
cid spectra
8

Similar Publications

Miniaturized mass spectrometers offer significant potential for in situ analysis due to their high specificity and portability. In traditional data-dependent acquisition (DDA) mode, precursor ions for tandem analysis are selected based on the full-scan mass spectrum. However, in situ applications often require the direct analysis of complex samples without extensive sample pretreatment, making them susceptible to chemical noise that can result in false negatives.

View Article and Find Full Text PDF

Mucosal-associated invariant T (MAIT) cells represent a unique unconventional T cell population important in eliciting immunomodulatory responses in a range of diseases, including infectious diseases, autoimmunity and cancer. This innate-like T cell subset predominantly express CD8 in humans. Unlike conventional CD8 T cells, which recognize peptide antigen presented by polymorphic major histocompatibility complex (MHC) molecules, MAIT cells are restricted by MR1, a non-polymorphic antigen-presenting molecule widely expressed in multiple tissues.

View Article and Find Full Text PDF

To explore the mechanism of the classic formula Sanpian Decoction in treating chronic migraine, this study employed the four-dimensional data-dependent acquisition(4D-DIA) proteomics to analyze the effect of the decoction on chronic migraine in rats and experimentally verified the key differentially expressed proteins. Firstly, SD male rats were randomly divided into groups and repeatedly injected with nitroglycerin to prepare a chronic migraine model. After 7 consecutive days of gavage, rat grimace scale(RGS) was employed to evaluate the treatment efficacy.

View Article and Find Full Text PDF

Purpose: There are a number of algorithms for smooth -norm (SL0) approximation. In most of the cases, sparsity level of the reconstructed signal is controlled by using a decreasing sequence of the modulation parameter values. However, predefined decreasing sequences of the modulation parameter values cannot produce optimal sparsity or best reconstruction performance, because the best choice of the parameter values is often data-dependent and dynamically changes in each iteration.

View Article and Find Full Text PDF

High-throughput mass spectrometry (MS) has witnessed rapid advancements and has found extensive applications across various disciplines. It enables the fast and accurate analysis of large sample sets, delivering a 10-fold or greater enhancement in analytical throughput when compared to conventional LC-MS methods. However, the signal duration in these high-throughput MS technologies is typically confined to a narrow range, presenting challenges for workflows demanding prolonged signal durations.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!